http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
문미선(Moon Mi-Seon),정지나(Jung Ji-Na),가참희(Ka Cham-Hee),이진숙(Lee Jin-Sook),태춘섭(Tae Choon-Seob) 한국태양에너지학회 2011 한국태양에너지학회 학술대회논문집 Vol.2011 No.4
Presently, various building certification systems are being enforced in Korea. However, people are in confusion and have an aptitude to waste time and money because these certification systems for buildings have very similar criteria. After investigating the foreign certification systems and domestic certification systems for the building, it is required that some of similar building certification systems are integrated.
이성옥(Lee, Sung-Ok),배철학(Bae, Cheol-Hak) 대한건축학회 2012 대한건축학회논문집 Vol.28 No.11
The purpose of this study is to analyze problems and suggest improvements via a status analysis of evaluation criteria and a method for three years after revisions to the standard of the Housing Performance Grading Indication System. The grade distribution works of four accreditation authorities were searched for grading distribution by performance item for 144 cases acknowledged for a ‘new standard’ (revised standard). It was revealed that ‘unequal distribution’, in which only certain grading was focused on, and ‘no-grading’, in which specific grading was not shown occurred on 17 items amongst the entire 27 performance items. The items shown only in ‘unequal distribution’ were generated for crime prevention content and horizontal evacuation distance. Only ‘no grading’ items were generated in seven items, which were heavy-weight floor impact sound insulation, remodeling & maintenance(common space), daylight, home networks, fire detection & warning facilities, smoke release & evacuation facilities, and so on. Items in which both ‘unequal distribution’ and ‘no grading’ were generated include noise emission in bathrooms, outside noise in sound insulation-related grading, remodeling & maintenance(private space), durability, and application of low emission product, ventilation performance for household units, consideration for the socially underprivileged, such as the elderly, etc. (private space), fire resistance performance. A commonly used method was applied to the evaluation criteria of each performance item in which ‘unequal distribution’ occurred for construction, and this is grading can be acknowledged without much difficulty. This shows that the housing performance grading acknowledgement criteria is lacking in discrimination from others. Evaluation criteria not showing ★★★★ amongst the evaluation criteria of each performance item shows that it is a criteria that is quite difficult to acknowledge for performance grading, and items not occurring ★ shows that a construction method was applied, which is basically applied to current apartment housing, and thus has no discrimination from others.
주택성능등급과 친환경건축물의 빛환경 평가방법 상관성 연구
홍구표(Hong Goo-Pyo),박철용(Park Cheol-Yong),이종상(Lee Jong-Sang),장동운(Jang Dong-Woon) 한국건축친환경설비학회 2008 한국건축친환경설비학회 학술발표대회 논문집 Vol.- No.-
It is very important the day lighting in built environment. It was different the method of daylighting performance in the Housing performance indicator system and the Green Building Certification Criteria. Case studies were evaluated through each program. The results were simply compared and analyzed. The purpose of this study is to investigate the relationship of the results in them.
임석호(Lim Seok-Ho),지장훈(Ji Jang-Hun),김수암(Kim Soo-Am) 대한건축학회 2009 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.29 No.1(계획계)
Housing Performance Rating Indication System was started in 2006. The aim of Housing Performance Rating Indication is to provide the guideline of housing performance. Repair Convenience is similar to Remodeling. Remodeling has been paid more attention as an alternative for reconstruction. Especially, now the actual house supply is facing almost 100%, it is time to keep and maintenance management of apartment buildings, and ultimately it will expand the Long life housing. Especially consumers has to have a right to select apartment buildings by comparing performance of house. For construction companies, they need a performance code that standardized by government, so they can provide a certain performing house. The purpose of a study is to analyze the result of repair convenience about the applied project recently which is the basis for long life housing. The method of study is to use the data of Housing Performance grade indication. The result of the analysis will be used for upgrade Housing Performance Rating Indication System.
임석호(Lim Seok-Ho),지장훈(Ji Jang-Hun),김수암(Kim Soo-Am) 대한건축학회 2009 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.29 No.1
Housing Performance Rating Indication System was started in 2006. The aim of Housing Performance Rating Indication is to provide the guideline of housing performance. Repair Convenience is similar to Remodeling. Remodeling has been paid more attention as an alternative for reconstruction. Especially, now the actual house supply is facing almost 100%, it is time to keep and maintenance management of apartment buildings, and ultimately it will expand the Long life housing. Especially consumers has to have a right to select apartment buildings by comparing performance of house. For construction companies, they need a performance code that standardized by government, so they can provide a certain performing house. The purpose of a study is to analyze the result of repair convenience about the applied project recently which is the basis for long life housing. The method of study is to use the data of Housing Performance grade indication. The result of the analysis will be used for upgrade Housing Performance Rating Indication System.