http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Implementation of BOC Signal Acquisition Using a DSP/FPGA Board
Yu-Hsuan Chen,Jyh-Ching Juang,Tsai-Ling Kao 한국항해항만학회 2006 한국항해항만학회 학술대회논문집 Vol.2 No.-
Future GNSS signal using BOC modulation brings the advantages of positioning accuracy and multipath rejection. However, the BOC signal has an ambiguous autocorrelation function that complicates the process of acquisition. Three techniques that solve the ambiguous problem are BPSK-like, Sub Carrier Phase Cancellation, and Bump Jumping. In this paper, these methods are implemented by means of a DSP/FPGA board. Moreover, an experiment is conducted to examine and compare the performance of these techniques.
Yu-Hsuan Lu,Dan Chen,Sheng-Fu Hsiao,Ching-Jan Chen,Hung-Shou Nien 전력전자학회 2015 ICPE(ISPE)논문집 Vol.2015 No.6
In recent years, the ripple-based constant on-time (RBCOT) control scheme for voltage regulators has been adopted in many applications because of its high efficiency feature under light-load conditions. However, a RBCOT control suffers from output-voltage offset problem. Therefore, an offset correction circuit (OC) is often added to the basic RBCOT scheme to correct the problem. In the OC circuit, there is a RC filter. The size of this RC filter not only affects the circuit stability and converter transient responses but also directly affects the controller chip size/cost. The main focus of the present paper is to investigate the relationship between the RC filter value and the feedback stability so that RC value can be minimized while avoiding circuit instability. A time-domain analysis approach is proposed to model OCRBCOT scheme for a buck converter configuration. Experimental and simulation results are given for verification.
Hsuan Franziska Wu,Tamara G. Amstislavskaya,Pin-Hsuan Chen,Ting-Feng Wu,Yu-Hung Chen,Chun-Ping Jen 한국바이오칩학회 2016 BioChip Journal Vol.10 No.3
Sample preconcentration is an important step that increases the accuracy of subsequent detection, especially for samples with extremely low concentrations. Due to the overlap of electrical double layers in a nanofluidic channel, the concentration polarization effect can be generated by applying an electric field. A nonlinear electrokinetic flow is induced, which results in the fast accumulation of proteins in front of the induced ionic depletion zone, the so-called exclusion- enrichment effect. In this way, a protein sample can be driven by electroosmotic flow and accumulated at a specific location. In the present study, a nanofluidic preconcentrator fabricated with the help of junction gap electric breakdown was integrated with microelectrodes for immunoassay. The preconcentration chip for proteins was fabricated using simple standard soft lithography with a polydimethylsiloxane replica. Human galectin-1 proteins from the cell lysate of T24 cells were concentrated and immunoassayed in the proposed microchip. The capability of the proposed microchip for concentrating multiple proteins from cell lysates and immunoassays after preconcentration was demonstrated. Immunosensing was evaluated by measurements of both fluorescence intensities and impedance, which proved the enhancement of preconcentration for immunoassay.
IPO Underwriting and Subsequent Lending
Hsuan-Chi Chen,Li-Ping Chen,Keng-Yu Ho,Pei-Shih Weng 한국재무학회 2012 한국재무학회 학술대회 Vol.2012 No.09
This study investigates the relation between IPO underwriting and subsequent lending. We find that when a bank underwrites a firm’s IPO, the bank is more likely to provide the issuer with future loans at a lower cost, compared to banks without an IPO underwriting relationship. The evidence also suggests that the underwriting banks share information surplus with the IPO firms in the post-IPO loans, supporting the cost-saving hypothesis. Finally, when borrowing firms are more satisfied with the IPO outcomes, they are more likely to retain their underwriting banks as subsequent lenders. We find no evidence that underwriting banks would exploit such satisfaction by charging higher interest rates in the post-IPO loans.
Yu-Li Chen,Kung-Liahng Wang,Min-Yu Chen,Mu-Hsien Yu,Chen-Hsuan Wu,Yu-Min Ke,Yi-Jen Chen,Yin-Yi Chang,Keng-Fu Hsu,Ming-Shyen Yen 대한부인종양학회 2013 Journal of Gynecologic Oncology Vol.24 No.1
Objective: To evaluate the clinical outcome and parameters related to coexisting endometrial carcinoma in women with tissuediagnosed endometrial hyperplasia. Methods: Between January 1991 and December 2009, three hundred and eighty-six patients with the presumptive diagnosis of endometrial hyperplasia were retrieved. Among these, one hundred and twenty-five patients were identified as having coexisting endometrial carcinoma in hysterectomy specimens. The three hundred and eighty-six patients were divided into two groups: the hyperplasia-benign group (261 cases) and the hyperplasia-malignant group (125 cases). Several clinical parameters including age, menopausal status, history of abnormal uterine bleeding, obstetrical history, medical history of diabetes and hypertension, BMI, and preoperative pathologic results were investigated. Results: Age ≥53 (odds ratio [OR], 2.40; 95% confidence interval [CI], 1.26 to 4.57), menopausal status (OR, 2.07; 95% CI, 1.14to 3.76), diabetes history (OR, 7.33; 95% CI, 2.79 to 19.26), abnormal uterine bleeding (OR, 3.99; 95% CI, 1.22 to 13.02), atypical endometrial hyperplasia (OR, 7.38; 95% CI, 4.03 to 13.49), and body mass index ≥27 (OR, 3.24; 95% CI, 1.76 to 5.97) were independent risk factors for prediction of endometrial hyperplasia coexisting with endometrial carcinoma. The diagnostic efficacy of atypical endometrial hyperplasia to predict the endometrial hyperplasia coexisting with endometrial carcinoma was better than or similar to those of other independent factors and combinations of these factors. Conclusion: Coexisting malignancy should be considered when examining endometrial hyperplasia patients with the related risk factors, especially atypical endometrial hyperplasia.
Three-Level Bi-Directional Half-Bridge CLLC Resonant Converter for DC Micro-Grid
Hsuan-Yu Yueh,Jing-Yuan Lin,Haung-Jen Chiu,Chen-Yen Chu,Yu-Chen Chang,Sih-Yi Lee 전력전자학회 2019 ICPE(ISPE)논문집 Vol.2019 No.5
A Three-Level Bi-Directional Half-Bridge CLLC Resonant DC-DC converter for DC micro-grid application is studied on this paper, which uses dual resonant tanks to achieve wide range voltage regulation and meanwhile employs bi-directional capability. All power switches on this converter can achieve ZVS function at the whole load and the voltage stress on all power switches at both sides can be clamped at half of input voltage and output voltage since the three-level circuit architecture using the proposed synchronous rectifier (SR) control, therefore, the voltage stresses of the transformer, resonant tanks, power switches and other components are only half compared with conventional half-bridge CLLC resonant converter, the downsizing rated of components selection can be more flexible. Finally, the laboratory prototype is built to verify the performance of voltage balancing on input/output capacitor, voltage stress on switches and efficiency, the measured efficiency can be up to 95.6% over different load conditions.
Chou, Yi-Hsuan,Choo, Kwang-Ho,Chen, Shiao-Shing,Yu, Jui-Hsuan,Peng, Ching-Yu,Li, Chi-Wang Elsevier 2018 Separation and purification technology Vol.198 No.-
<P><B>Abstract</B></P> <P>A chemical reduction process was proposed to recover copper from the retentate of polyelectrolyte enhanced ultrafiltration (PEUF). Three polyelectrolytes (PSS, PAA, and PEI) containing various functional groups and molecular weights were studied to explore their effects on the copper removal in PEUF and on the copper recovery by chemical reduction under various pH conditions. With PSS which contains sulfonic group, copper was removed reasonably well (ca. 75%) by PEUF even under acidic pH value of 3. With PAA which contains carboxylic group, copper removal was a bit low (∼60%) under pH 3.0 but increased substantially at pH 4.0. A branched PEI having amine group achieved the highest Cu removal of 94% at pH 3. The copper removal efficiency decreased slightly with increasing pH due to the high permeation of PEI through membrane.</P> <P>Chemical reduction achieved the complete copper recovery for solution containing PSS. The copper recovery efficiencies were more than 95% for PAA solution with pH values ranging from 3 to 9 at reaction time of one hour. For PEI, the recovery efficiencies ranged from 20 to 96% and were pH dependent. Aggregated and settled readily copper particles were produced by chemical reduction in PSS solution. XRD analysis identified cuprous oxide in all of the samples. Dependent of pH and polyelectrolytes, additional peaks matching those of elemental copper were identified. TGA analysis showed that solids produced from PSS and PAA systems contained no polyelectrolytes while solid collected from PEI system contained 32% of polyelectrolyte.</P> <P><B>Highlights</B></P> <P> <UL> <LI> Polyelectrolytes with different functional groups and MW were applied in PEUF. </LI> <LI> Effects of polyelectrolytes and pH on the reduction of copper were studied. </LI> <LI> Both Cu<SUB>2</SUB>O and Cu<SUP>0</SUP> were identified by XRD analysis of solids obtained. </LI> </UL> </P>
Yen-Hsiang Huang,Kuo-Hsuan Hsu,Jeng-Sen Tseng,Kun-Chieh Chen,Chia-Hung Hsu,Kang-Yi Su,Jeremy J. W. Chen,Huei-Wen Chen,Sung-Liang Yu,Tsung-Ying Yang,Gee-Chen Chang 대한암학회 2018 Cancer Research and Treatment Vol.50 No.4
Purpose The main objective of this study was to investigate the relationship among the clinical characteristics and the frequency of T790M mutation in advanced epidermal growth factor receptor (EGFR)mutant lung adenocarcinoma patients with acquired resistance after firstline EGFRtyrosine kinase inhibitor (TKI) treatment. Materials and Methods We enrolled EGFR-mutant stage IIIB-IV lung adenocarcinoma patients, who had progressed to prior EGFR-TKI therapy, and evaluated their rebiopsy EGFRmutation status. Results A total of 205 patients were enrolled for analysis. The overall T790M mutation rate of rebiopsy was 46.3%. The T790M mutation rates among patients with exon 19 deletion mutation, exon 21 L858R point mutation, and other mutations were 55.0%, 37.3%, and 27.3%, respectively. Baseline exon 19 deletion was associated with a significantly higher frequency of T790M mutation (adjusted odds ratio, 2.14; 95% confidence interval [CI], 1.20 to 3.83; p=0.010). In the exon 19 deletion subgroup, there was a greater prevalence of T790M mutation than other exon 19 deletion subtypes in patients with the Del E746-A750 mutation (61.6% vs. 40.6%; odds ratio, 2.35; 95% CI, 1.01 to 5.49; p=0.049). The progression- free survival (PFS) of first-line TKI treatment > 11 months was also associated with a higher T790M mutation rate (54.1% vs. 39.3%; adjusted odds ratio, 1.82; 95% CI, 1.02 to 3.25; p=0.044). Patients who underwent rebiopsy at metastatic sites had more chance to harbor T790M mutation (52.6% vs. 33.8%; adjusted odds ratio, 1.97; 95% CI, 1.06 to 3.67; p=0.032). Conclusion PFS of first-line EGFR-TKI, rebiopsy site, EGFR exon 19 deletion and its subtype Del E746- A750 mutation are associated with the frequency of T790M mutation.