RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Adolescent Scoliosis Screening in Nara City Schools: A 23-Year Retrospective Cross-Sectional Study

        Satoshi Yamamoto,Hideki Shigematsu,Fumihiko Kadono,Yukihiro Tanaka,Masataka Tatematsu,Akinori Okuda,Eiichiro Iwata,Munehisa Koizumi,Yasuhito Tanaka 대한척추외과학회 2015 Asian Spine Journal Vol.9 No.3

        Study Design: Retrospective cross-sectional study. Purpose: To determine the prevalence of idiopathic scoliosis, define the distribution of the curve magnitude, evaluate the accuracy of Moiré topography as a screening tool, and investigate the cost-effectiveness of our screening system. Overview of Literature: Early detection of idiopathic scoliosis provides the opportunity for conservative treatment before the deformity is noticeable. We believe that scoliosis screening in schools is useful for detection; however, screening programs are controversial owing to over referral of students who do not require further testing or follow-up. In Japan, school scoliosis screening programs are mandated by law with individual policies determined by local educational committees. We selected Moiré topography as the scoliosis screening tool for schools in Nara City. Methods: We selected Moiré topography as the scoliosis screening tool for schools in Nara City. We screened boys and girls aged 11–14 years and reviewed the school scoliosis screening results from 1990 to 2012. Results: A total of 195,149 children aged 11–14 years were screened. The prevalence of scoliosis (defined as ≥10° curvature) was 0.057%, 0.010%, and 0.059% in fifth, sixth, and seventh grade boys and 0.337%, 0.369%, and 0.727% in fifth, sixth, and seventh grade girls, respectively. The false-positive rate of our Moiré topography was 66.7%. The minimum cost incurred for scoliosis detection in one student was 2,000 USD. Conclusions: The overall prevalence of scoliosis was low in the students of Nara City schools. Over 23 years, the prevalence of scoliosis in girls increased compared to that in the first decade of the study.

      • Study on Evaluation of Coppice Landscape Depend on Healthiness of Plants

        Satoshi Yamamoto,Yue Shin,Naoki Takeda Korean Institute of Landscape Architecture 2004 Journal of the Korean institute of landscape archi Vol.2 No.-

        It is increasing scenery created as a result of pine wilt disease. The purpose of this study is to investigate the local resident's awareness against the scenery caused by pine wilt disease in their neighboring area, through the questionnaire investigation. The result showed that more than $40\%$ of the residents are not aware of such scenery in their local area, and about 30% of the residents did not know that those trees were dying. More than $40\%$ of the people do not know of the pine wilt disease as a general argument. Another question showed that the recognition of such scenery depends on the distance of the viewer. General residents don't worry about such scenery in the far distance in fact some of them think those are colored leaves. However, the nearer they see the trees, the higher they have negative feeling against it.

      • KCI등재

        CD57 (Leu-7, HNK-1) immunoreactivity seen in thin arteries in the human fetal lung

        Satoshi Ishizuka,Zhe Wu Jin,Masahito Yamamoto,Gen Murakami,Takeshi Takayama 대한해부학회 2018 Anatomy & Cell Biology Vol.51 No.2

        CD57 (synonyms: Leu-7, HNK-1) is a well-known marker of nerve elements including the conductive system of the heart, as well as natural killer cells. In lung specimens from 12 human fetuses at 10‒34 weeks of gestation, we have found incidentally that segmental, subsegmental, and more peripheral arteries strongly expressed CD57. Capillaries near developing alveoli were often or sometimes positive. The CD57-positive tissue elements within intrapulmonary arteries seemed to be the endothelium, internal elastic lamina, and smooth muscle layer, which corresponded to tissue positive for a DAKO antibody reactive with smooth muscle actin we used. However, the lobar artery and pulmonary arterial trunk as well as bronchial arteries were negative. Likewise, arteries in and along any abdominal viscera, as well as the heart, thymus, and thyroid, did not express CD57. Thus, the lung-specific CD57 reactivity was not connected with either of an endodermal- or a branchial arch-origin. CD57 antigen is a sugar chain characterized by a sulfated glucuronic acid residue that is likely to exist in some glycosphingolipids. Therefore, a chemical affinity or an interaction might exist between CD57-positive arterioles and glycosphingolipids originating from alveoli, resulting in acceleration of capillary budding to make contact with the alveolar wall. CD57 might therefore be a functional marker of the developing air-blood interface that characterizes the fetal lung at the canalicular stage.

      • KCI등재

        An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time

        Satoshi Shinozaki,Yoshimasa Miura,Yuji Ino,Kenjiro Shinozaki,Alan Kawarai Lefor,Hironori Yamamoto 대한소화기내시경학회 2016 Clinical Endoscopy Vol.49 No.1

        Background/Aims: Poor suction ability through a narrow working channel prolongs esophagogastroduodenoscopy (EGD). The aim of this study was to evaluate suction with a new ultrathin endoscope (EG-580NW2; Fujifilm Corp.) having a 2.4-mm working channel in clinical practice. Methods: To evaluate in vitro suction, 200 mL water was suctioned and the suction time was measured. The clinical data of 117 patients who underwent EGD were retrospectively reviewed on the basis of recorded video, and the suction time was measured by using a stopwatch. Results: In vitro, the suction time with the EG-580NW2 endoscope was significantly shorter than that with the use of an ultrathin endoscope with a 2.0-mm working channel (EG-580NW; mean ± standard deviation, 22.7±1.1 seconds vs. 34.7±2.2 seconds; p<0.001). We analyzed the total time and the suction time for routine EGD in 117 patients (50 in the EG-580NW2 group and 67 in the EG-580NW group). In the EG-580NW2 group, the total time for EGD was significantly shorter than that in the EG-580NW group (275.3±42.0 seconds vs. 300.6±46.5 seconds, p=0.003). In the EG-580NW2 group, the suction time was significantly shorter than that in the EG-580NW group (19.2±7.6 seconds vs. 38.0±15.9 seconds, p<0.001). Conclusions: An ultrathin endoscope with a 2.4-mm working channel considerably shortens the routine EGD time by shortening the suction time, in comparison with an endoscope with a 2.0-mm working channel. Background/Aims: Poor suction ability through a narrow working channel prolongs esophagogastroduodenoscopy (EGD). The aim of this study was to evaluate suction with a new ultrathin endoscope (EG-580NW2; Fujifilm Corp.) having a 2.4-mm working channel in clinical practice. Methods: To evaluate in vitro suction, 200 mL water was suctioned and the suction time was measured. The clinical data of 117 patients who underwent EGD were retrospectively reviewed on the basis of recorded video, and the suction time was measured by using a stopwatch. Results: In vitro, the suction time with the EG-580NW2 endoscope was significantly shorter than that with the use of an ultrathin endoscope with a 2.0-mm working channel (EG-580NW; mean ± standard deviation, 22.7±1.1 seconds vs. 34.7±2.2 seconds; p<0.001). We analyzed the total time and the suction time for routine EGD in 117 patients (50 in the EG-580NW2 group and 67 in the EG-580NW group). In the EG-580NW2 group, the total time for EGD was significantly shorter than that in the EG-580NW group (275.3±42.0 seconds vs. 300.6±46.5 seconds, p=0.003). In the EG-580NW2 group, the suction time was significantly shorter than that in the EG-580NW group (19.2±7.6 seconds vs. 38.0±15.9 seconds, p<0.001). Conclusions: An ultrathin endoscope with a 2.4-mm working channel considerably shortens the routine EGD time by shortening the suction time, in comparison with an endoscope with a 2.0-mm working channel.

      • SCIESCOPUSKCI등재

        Hybrid Sensor-less Control of Permanent Magnet Synchronous Motor in Low-speed Region

        Yamamoto, Yasuhiro,Funato, Hirohito,Ogasawara, Satoshi The Korean Institute of Power Electronics 2008 JOURNAL OF POWER ELECTRONICS Vol.8 No.4

        This paper proposes a method of improving the stability in sensor-less control of permanent magnet synchronous motors. The control method for low-speed region is divided into two: One is a high frequency method, which involves a problem of reverse rotation once misdetection of the permanent magnet polarity should occur, and another one is a current drive method, which has a problem that phase and speed oscillations are caused by quick speed changes. Hence, authors propose adoption of the current drive method for the basic control system with added compensation of stabilization by means of the high frequency method. This combination secures stable control with no risk of reversal and less vibration. In addition, authors have also considered a frequency separation filter of a shorter delay time so that current control performance will not lower even when high frequencies are introduced. This filter has achieved simplified compensation using repetitive characteristic through the utilization of the periodicity of high frequency current. Simulation and experiment have been conducted to verify that the stable performance of this system is improved.

      • KCI등재

        An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time

        Satoshi Shinozaki,Yoshimasa Miura,Yuji Ino,Kenjiro Shinozaki,Alan Kawarai Lefor,Hironori Yamamoto 대한소화기내시경학회 2015 Clinical Endoscopy Vol.48 No.6

        Background/Aims: Poor suction ability through a narrow working channel prolongs esophagogastroduodenoscopy (EGD). The aim of this study was to evaluate suction with a new ultrathin endoscope (EG-580NW2; Fujifilm Corp.) having a 2.4-mm working channel in clinical practice. Methods: To evaluate in vitro suction, 200 mL water was suctioned and the suction time was measured. The clinical data of 117 patients who underwent EGD were retrospectively reviewed on the basis of recorded video, and the suction time was measured by using a stopwatch. Results: In vitro, the suction time with the EG-580NW2 endoscope was significantly shorter than that with the use of an ultrathin endoscope with a 2.0-mm working channel (EG-580NW; mean ± standard deviation, 22.7±1.1 seconds vs. 34.7±2.2 seconds; p<0.001). We analyzed the total time and the suction time for routine EGD in 117 patients (50 in the EG-580NW2 group and 67 in the EG-580NW group). In the EG-580NW2 group, the total time for EGD was significantly shorter than that in the EG-580NW group (275.3±42.0 seconds vs. 300.6±46.5 seconds, p=0.003). In the EG-580NW2 group, the suction time was significantly shorter than that in the EG-580NW group (19.2±7.6 seconds vs. 38.0±15.9 seconds, p<0.001). Conclusions: An ultrathin endoscope with a 2.4-mm working channel considerably shortens the routine EGD time by shortening the suction time, in comparison with an endoscope with a 2.0-mm working channel.

      • KCI등재후보

        Radiation-induced synthesis of Au/Fe oxide nanocomposite particles for magnetic separation of biomolecules

        Satoshi Seino,Takuya Kinoshita,Yohei Otome,Takashi Nakagawa,Kenji Okitsu,Tadachika Nakayama,Tohru Sekino,KoichiNiihara,Takao A. Yamamoto 한양대학교 세라믹연구소 2004 Journal of Ceramic Processing Research Vol.5 No.2

        Nanocomposite particles composed of gold and iron oxide were synthesized with various ratios of gold and iron oxide in an aqueous phase using γ-rays. Iron oxide nanoparticles of γ-Fe2O3 or Fe3O4 were used as a magnetic phase on which gold nanoparticles with average diameters of 5-10 nm were supported. The efficiency of magnetic separation of biomolecules by the present nanocomposite particles was investigated using glutathione as a model compound. The amount of glutathione magnetically separated was significantly enhanced by the supported gold nanoparticles.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼