RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        A monophosphonic group-functionalized ion-imprinted polymer for a removal of Fe3+ from highly concentrated basic chromium sulfate solution

        Guang-jin Zhu,Hai-yan Tang,Peng-hui Qing,Hong-ling Zhang,Xi-chuan Cheng,Zai-hua Cai,Hong-bin Xu,Yi Zhang 한국화학공학회 2020 Korean Journal of Chemical Engineering Vol.37 No.5

        An ion-imprinted polymer (IIP) with monophosphonic groups was prepared by thermal copolymerization. Bis(2-methacryloxyethyl) phosphate (BMAOP) was used as functional monomer to react with Fe3+ in dimethyl sulfoxide (DMSO). Ethylene glycol dimethacrylate (EGDMA) was used as cross-linker during polymerization process. A suitable molar ratio of BMAOP to Fe3+ was investigated by UV/Vis/NIR Spectrometer and ICP-OES. The obtained results showed that the monophosphonic groups could be selectively combined with Fe3+ in solutions containing other coexisting ions, and the selectivity could be further enhanced by ion-imprinted process. The prepared IIP was used for removing trace Fe3+ from high concentration basic chromium sulfate solutions. After adsorption process, the concentration of Fe3+ could be reduced from 4.486mg L1 to 0.171mg L1, which was much lower than the concentration in the solution treated by non-imprinted polymer (NIP). Moreover, the IIP exhibited excellent recyclability after six adsorption-desorption cycles.

      • KCI등재

        Comparing Outcomes of Banana-Shaped and Straight Cages in Transforaminal Lumbar Interbody Fusion for Lumbar Degenerative Diseases: A Systematic Review and Meta-Analysis

        Guang-Xun Lin,Li-Ru He,Jin-Niang Nan,Wen-Bin Xu,Keyi Xiao,Zhiqiang Que,Shang-Wun Jhang,Chien-Min Chen,Ming-Tao Zhu,Gang Rui 대한척추신경외과학회 2024 Neurospine Vol.21 No.1

        Objective: This meta-analysis aims to refine the understanding of the optimal choice between different cage shapes in transforaminal lumbar interbody fusion (TLIF) by systematically comparing perioperative data, radiological outcomes, clinical results, and complications associated with banana-shaped and straight bullet cages. Methods: A meticulous literature search encompassing PubMed, Embase, Scopus, Web of Science, China Knowledge Network, and Wanfang Data was executed up to October 5, 2023. Inclusion criteria focused on studies comparing banana-shaped and straight bullet cages in TLIF. The quality of included studies was assessed using appropriate tools such as the Newcastle-Ottawa Scale (NOS) for nonrandomized studies. Rigorous evaluations were performed for radiographic outcomes, including disc height (DH), segmental lordosis (SL), lumbar lordosis (LL), subsidence, and fusion rates. Clinical outcomes were meticulously evaluated using visual analogue scale (VAS), Oswestry Disability Index (ODI), and complications. Results: The analysis incorporated 7 studies, involving 573 patients (297 with banana-shaped cages, 276 with straight cages), all with NOS ratings exceeding 5 stars. No statistically significant differences were observed in operative time, blood loss, or hospitalization between the 2 cage shapes. Banana-shaped cages exhibited greater changes in DH (p = 0.001), SL (p = 0.02), and LL (p = 0.01). Despite statistically higher changes in ODI for straight cages (26.33, p < 0.0001), the actual value remained similar to banana-shaped cages (26.15). Both cage types demonstrated similar efficacy in VAS, complication rates, subsidence, and fusion rates. Conclusion: Although banana-shaped cages can excel in restoring DH, SL, and LL, straight bullet cages can provide comparable functional improvements, pain relief, and complication rates.

      • KCI등재

        Three New 29 Carbon Skeletons Pentacyclic Triterpenoids and S-equol from Biogas Slurry

        Jian-Feng Xu,Hui-Bin Wu,Ding-Cai Liu,Long Sha,Wen-Hui Wu,Hua Fan,Yishan Song,Hong-Guang Zhu 대한화학회 2015 Bulletin of the Korean Chemical Society Vol.36 No.12

        Bioactive natural products were firstly obtained from biogas slurry. Three new 29 carbon skeletons of the pentacyclic triterpenoid compounds 24-norolean-12-ene-3,22-dione (1), 3β-hydroxy-24-norolean-12-ene-22-one (2), 3α-hydroxy-24-norolean-12-ene-22-one (3), as well as one known compound S-equol (4) were isolated and purified from the MeOH extract of chicken manure biogas slurry. The molecular structures of the four compounds were elucidated based on the extensive spectroscopic data analysis, and the structure of Compound 1 was further confirmed by single-crystal X-ray diffraction. The structures of Compounds 1, 2, and 3 are similar with oleanolicum and hederagenin that has excellent anti-tumor activities. The cytotoxicity against five cancer cell lines (Hela, A549, MCF7, PC3, and B16) of Compounds 1–4 was tested. Similar to Compound 4 (S-equol), Compounds 1–3 (pentacyclic triterpenoids) showed cytotoxicity activity against different tumor cell lines. Compounds 1–3 showed slightly lower cytotoxicity activities than Compound 4. The IC50 of Compound 4 was determined to be 9.7–27.6 μM, while the IC50 values of 1–3 were 17.6–65.3 μM. There are no significant differences in the cytotoxicity capacities between Compounds 1, 2, and 3.

      • KCI등재

        A Comparative Study of Camouflage Printing Color Matching Based on Monitor and Paper Card

        Yu-wen Wang,Qing-zhu Yi,Yi Ding,Guang-xin Wu,Jing-bin Zhang,Ni Wang 한국섬유공학회 2021 Fibers and polymers Vol.22 No.4

        To improve the accuracy of color reproduction for camouflage printing, a new color matching method, namedmonitor-paper-fabric, was proposed by importing color management into textiles, which matched the printing pastesaccording to the color of the paper card printed by the ink-jet printer after color management. Not like the traditional colormatching method, it matched the printing pastes according to the color from computer monitor after color correction. Twocolor matching methods were analyzed by comparing the color difference. It was found that the “monitor-paper-fabric” colormatching method could be considered as a convenient and feasible color matching method. Most color differences betweenthe monitor and the fabric in the camouflage pattern were reduced to lower than 4, except for color blocks 5 and 6. Inaddition, the color differences of six color blocks between the paper and the fabric were all less than 3.5, and were lower thanthose between the monitor and the fabric. The color consistency between the paper and the fabric was better than thatbetween the monitor and the fabric.

      • KCI등재

        High-j Proton h11/2 and g7/2 Intruder Bands in 113In

        Ma Ke Yan,Lu Jing Bin,Ma Ying Jun,Li Jian,Yang Dong,Sun Wu Ji,Wang Hao,Pan Hao Nan,Wang Jia Qi,Yang Qing Yu,Zhang Da Ming,Zhu Li Hua,Wu Xiao Guang,Zheng Yun,Li Cong Bo 한국물리학회 2020 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.76 No.12

        Excited states of 113In have been populated through the heavy-ion fusion evaporation reaction 110Pd(7Li, 4n)113In. A new band with the configuration of a proton d5/2 orbital is identified. Two ΔI = 2 intruder bands, built on the πh11/2 and the πg7/2 orbitals, have been extended to spins (63/2-)ħ and (55/2+)ħ, respectively. The negative-parity πh11/2 intruder band shows a smooth increase in aligned spin, which is attributed to a strong proton-neutron interaction. The properties of the positive-parity πg7/2 band are discussed based on tilted axis cranking model calculations, and the features of the antimagnetic rotation for this band are shown after backbend. Furthermore, the contributions of the two-shears-like mechanism, the neutron (gd)ν shell and the core rotation are investigated for the positive-parity πg7/2 band.

      • Genetic Variants at 6p21.1 and 7p15.3 Identified by GWASs of Multiple Cancers and Ovarian Cancer Risk: a Case-control Study in Han Chinese Women

        Li, Da-Ke,Han, Jing,Liu, Ji-Bin,Jin, Guang-Fu,Qu, Jun-Wei,Zhu, Meng,Wang, Yan-Ru,Jiang, Jie,Ma, Hong-Xia Asian Pacific Journal of Cancer Prevention 2014 Asian Pacific journal of cancer prevention Vol.15 No.1

        A recent study summarized several published genome-wide association studies (GWASs) of cancer and reported two pleiotropic loci at 6p21.1 and 7p15.3 contributing to multiple cancers including lung cancer, noncardia gastric cancer (NCGC), and esophageal squamous-cell carcinoma (ESCC) in Han Chinese. However, it is not known whether such genetic variants have similar effects on the risk of gynecologic cancers, such as ovarian cancer. Hence, we explored associations between genetic variants in 6p21.1 and 7p15.3 and ovarian cancer risk in Han Chinese women. We performed an independent case-control study by genotyping the two loci (rs2494938 A > G at 6p21.1 and rs2285947 A > G at 7p15.3) in a total of 377 ovarian cancer cases and 1,034 cancer-free controls using TaqMan allelic discrimination assay. We found that rs2285947 at 7p15.3 was significantly associated with risk of ovarian cancer with per allele odds ratio (OR) of 1.33 [95% confidence interval (CI): 1.08-1.64, P=0.008]. However, no significant association was observed between rs2494938 and ovarian cancer risk. Our results showed that rs2285947 at 7p15.3 may also contribute to the development of ovarian cancer in Han Chinese women, further suggesting pleiotropy of 7p15.3 in multiple cancers.

      • KCI등재

        Five-Year Follow-Up Results of a Randomized Controlled Trial Comparing Bipolar Plasmakinetic and Monopolar Transurethral Resection of the Prostate

        Chang-Ying Xie,Xing-Huan Wang,Guang-Bin Zhu,Xiang-Bin Liu 연세대학교의과대학 2012 Yonsei medical journal Vol.53 No.4

        Purpose: To report the 5-year follow-up results of a randomized controlled trial comparing bipolar transurethral resection of the prostate (TURP) with standard monopolar TURP for the treatment of benign prostatic obstruction (BPO). Materials and Methods: A total of 220 patients were randomized to bipolar plasmakinetic TURP (PK-TURP) or monopolar TURP (M-TURP). Catheterization time was the primary endpoint of this study. Secondary outcomes included operation time, hospital stay, as well as decline in postoperative serum sodium and hemoglobin levels. All patients were assessed preoperatively and followed-up at 1, 6, 12, 24, 36, 48, and 60 months postoperatively. Parameters assessed included quality of life, transrectal ultrasound, serum prostate-specific antigen level, postvoid residual urine volume, maximum urinary flow rates (Qmax), and International Prostate Symptom Score. Patient baseline characteristics, perioperative data including complications, and postoperative outcomes were compared. Complication occurrence was graded according to the modified Clavien classification system. Results: PK-TURP was significantly superior to M-TURP in terms of operation time, intraoperative irrigation volume, resected tissue weight, decreases in hemoglobin and sodium, postoperative irrigation volume and time, catheterization time, and hospital stay. At 5 years postoperatively, efficacy was comparable between arms. No differences were detected in safety outcomes except that the clot retention rate was significantly greater after M-TURP. Conclusion: Our results indicate that PK-TURP is equally as effective in the treatment of BPO, but has a more favorable safety profile in comparison to M-TURP. The clinical efficacy of PK-TURP is long-lasting and comparable with M-TURP.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼