      • Does Adding Diffuse Optical Tomography to Sonography Improve Differentiation Between Benign and Malignant Breast Lesions? : Observer Performance Study

        La Yun, Bo,Kim, Sun Mi,Jang, Mijung,Ahn, Hye Shin,Lyou, Chae Yeon,Kim, Mi Sun,Kim, Sun Ah,Song, Tai-Kyong,Yoo, Yangmo,Chang, Jin Ho,Kim, Youngmi American Institute of Ultrasound in Medicine 2015 Journal of ultrasound in medicine Vol.34 No.5

        <P>Objectives-The purpose of this study was to investigate the added value of diffuse optical tomographic categories combined with conventional sonography for differentiating between benign and malignant breast lesions. Methods-In this retrospective database review, we included 145 breast lesions (116 benign and 29 malignant) from 145 women (mean age, 46 years; range, 16-86 years). Five radiologists independently reviewed sonograms with and without a diffuse optical tomographic category. Each lesion was scored on a scale of 0% to 100% for suspicion of malignancy and rated according to the American College of Radiology Breast Imaging Reporting and Data System classification. Diagnostic performance was analyzed by comparing area under receiver operating characteristic curve values. Reader agreement was assessed by intraclass correlation coefficients. Results-In the multireader multicase receiver operating characteristic analysis, adding a diffuse optical tomographic category to sonography improved the diagnostic accuracy of sonography (mean areas under the curve, 0.923 for sonography alone and 0.969 for sonography with diffuse optical tomography; P = .039). The interobserver correlation was also improved (0.798 for sonography alone and 0.904 for sonography with diffuse optical tomography). The specificity increased for 4 reviewers from a mean of 19.5% to 45.8% (P < .001 for reviewers 1-4; P = .238 for reviewer 5) with no significant change in the sensitivity. When the diffuse optical tomographic category was applied strictly, the specificity increased for all reviewers from a mean of 19.5% to 68.3% (P < .001 for all reviewers) with no significant change in the sensitivity. Conclusions-The addition of diffuse optical tomographic categories to sonography may improve diagnostic performance and markedly decrease false-positive biopsy recommendations.</P>

      • KCI등재후보

        Current Practices in Breast Magnetic Resonance Imaging: a Survey Involving the Korean Society of Breast Imaging

        Yun, Bo La,Kim, Sun Mi,Jang, Mijung,Kang, Bong Joo,Cho, Nariya,Kim, Sung Hun,Koo, Hye Ryoung,Chae, Eun Young,Ko, Eun Sook,Han, Boo-Kyung Korean Society of Magnetic Resonance in Medicine 2017 Investigative Magnetic Resonance Imaging Vol.21 No.4

        Purpose: To report on the current practices in breast magnetic resonance imaging (MRI) in Korea. Materials and Methods: We invited the 68 members of the Korean Society of Breast Imaging who were working in hospitals with available breast MRI to participate in a survey on how they performed and interpreted breast MRI. We asked one member from each hospital to respond to the survey. A total of 22 surveys from 22 hospitals were analyzed. Results: Out of 22 hospitals, 13 (59.1%) performed at least 300 breast MRI examinations per year, and 5 out of 22 (22.7%) performed > 1200 per year. Out of 31 machines, 14 (45.2%) machines were 1.5-T scanners and 17 (54.8%) were 3.0-T scanners. All hospitals did contrast-enhanced breast MRI. Full-time breast radiologists supervised the performance and interpreted breast MRI in 19 of 22 (86.4%) of hospitals. All hospitals used BI-RADS for MRI interpretation. For computer-aided detection (CAD), 13 (59.1%) hospitals sometimes or always use it and 9 (40.9%) hospitals did not use CAD. Two (9.1%) and twelve (54.5%) hospitals never and rarely interpreted breast MRI without correlating the mammography or ultrasound, respectively. The majority of respondents rarely (13/21, 61.9%) or never (5/21, 23.8%) interpreted breast MRI performed at an outside facility. Of the hospitals performing contrast-enhanced examinations, 15 of 22 (68.2%) did not perform MRI-guided interventional procedures. Conclusion: Breast MRI is extensively performed in Korea. The indication and practical patterns are diverse. The information from this survey would provide the basis for the development of Korean breast MRI practice guidelines.

      • SCOPUSKCI등재

        Regulation of B cell activating factor (BAFF) receptor expression by NF-${\kappa}B$ signaling in rheumatoid arthritis B cells

        Woo, Yun-Ju,Yoon, Bo-Young,Jhun, Joo-Yeon,Oh, Hye-Jwa,Min, Se-Won,Cho, Mi-La,Park, Sung-Hwan,Kim, Ho-Youn,Min, Jun-Ki Korean Society for Biochemistry and Molecular Bion 2011 Experimental and molecular medicine Vol.43 No.6

        B cells play an important role in the pathogenesis of rheumatoid arthritis (RA). High levels of B cell activating factor (BAFF) are detected in autoimmune diseases. BAFF and BAFF receptor (BAFF-R) are expressed in B and T cells of RA synovium. The study was undertaken to identify the NF-${\kappa}B$ signal pathway involved in the induction of BAFF-R in human B cells. Immunohistochemical staining of NF-${\kappa}B$ p65, NF-${\kappa}B$ p50, BAFF, and BAFF-R was performed on sections of synovium from severe and mild RA and osteoarthritis (OA) patients. Peripheral blood mononuclear cells (PBMCs) were isolated from control and RA patients and B cells were isolated from controls. BAFF-R was analyzed by flow cytometry, realtime PCR and confocal staining after treatment with NF-${\kappa}B$ inhibitors. NF-${\kappa}B$ p65, NF-${\kappa}B$ p50, BAFF, and BAFF-R were highly expressed in severe RA synovium relative to mild RA synovium or OA synovium. BAFF-R expression was reduced by NF-${\kappa}B$ inhibitors in PBMCs and B cells from normal controls. We also showed reduction in expression of BAFF-R via inhibition of the NF-${\kappa}B$ pathway in PBMCs of RA patients. BAFF/BAFF-R signaling is an important mechanism of pathogenesis in RA and that BAFF-R reduction by NF-${\kappa}B$ blocking therapy is another choice for controlling B cells in autoimmune diseases such as RA.

      • KCI등재

        Association between Bone Mineral Density and Coronary Atherosclerotic Plaque According to Plaque Composition: Registry for the Women Health Cohort for Bone, Breast, and Coronary Artery Disease Study

        김경민,Yeonyee E. Yoon,Bo La Yun,Jung-Won Suh 대한골대사학회 2022 대한골대사학회지 Vol.29 No.2

        Background: Although biological links are unclear, low bone density and atherosclerosis are inversely associated. This study evaluated the association between bone mineral density (BMD) and coronary computed tomographic angiography (CCTA) findings, including coronary artery calcification (CAC) score and the presence, extent, and composition of coronary atherosclerotic plaque (CAP) in asymptomatic women. Methods: A symptomatic women aged ≥40 years (N=2, 100; median age, 52 years; range, 40-80 years) were selected from a retrospective observational cohort and stratified into normal, osteopenia, and osteoporosis groups according to BMD T-score grades. We evaluated CAC score and assessed the presence, extent, and stenosis severity of CAP on CCTA. Additionally, CAP was categorized as calcified, mixed, or non-calcified according to calcified component valiums (>130 Hounsfield units). Results: Osteopenia and osteoporosis were found in 28.8% and 5.3% of participants, respectively. CAC score and CAC severity significantly increased with decreased BMD grades (from normal to osteoporosis). The presence of CAP (overall, 15.6%; normal, 12.6%; osteopenia, 20.2%; osteoporosis, 28.8%; P<0.001) and number of segments with CAP significantly increased with decreased BMD grades. Furthermore, the number of segments with calcified or mixed plaques, excluding non-calcified plaques, increased with decreased BMD grades. Although most associations were attenuated or disappeared after adjusting for age and other covariates, calcified plaques showed a strong and age-independent association with BMD grades. Conclusions: The presence and severity of CAC and CAP were significantly associated with BMD severity in asymptomatic women, particularly for the presence of calcified plaques. Further studies are required to determine the association between vascular calcification and bone health status.

      • KCI등재SCOPUS

        Uterine fibroid shrinkage after short-term use of selective progesterone receptor modulator or gonadotropin-releasing hormone agonist

        ( Min Jin Lee ),( Bo Seong Yun ),( Seok Ju Seong ),( Mi-la Kim ),( Yong Wook Jung ),( Mi Kyoung Kim ),( Hyo Sook Bae ),( Da Hee Kim ),( Ji Young Hwang ) 대한산부인과학회 2017 Obstetrics & Gynecology Science Vol.60 No.1

        Objective The aim of this study was to evaluate the effect of short-term use of selective progesterone receptor modulator (SPRM) or gonadotropin-releasing hormone (GnRH) agonist on uterine fibroid shrinkage among Korean women. Methods This retrospective study involved 101 women with symptomatic uterine fibroids who received ulipristal acetate (SPRM, n=51) and leuprolide acetate (GnRH agonist, n=50) for 3 months between November 2013 and February 2015. The fibroid volume was measured both before and after treatment using ultrasonography, computed tomography, and magnetic resonance imaging. The outcomes were compared between the SPRM and GnRH agonist groups. Results The median rate of fibroid volume reduction after SPRM treatment was 12.4% (IQR -14.5% to 40.5%) which was significantly lower than the reduction rate observed after GnRH agonist treatment (median 34.9%, IQR 14.7% to 48.6%, P=0.004). 19 of 51 (37.3%) patients with SPRM treatment did not show any response of volume shrinkage, while 7 of 50 (14.0%) women with GnRH agonist showed no response (P=0.007). Conclusion Short-term SPRM treatment yields lower volume reduction than GnRH agonist treatment in Korean women with symptomatic fibroids. Further large-scale randomized trials are needed to confirm our findings.

      • KCI등재

        Background Breast Parenchymal Signal During Menstrual Cycle on Diffusion-Weighted MRI: A Prospective Study in Healthy Premenopausal Women

        Kim Yeon Soo,Yun Bo La,Chu A Jung,Lee Su Hyun,Shin Hee Jung,Kim Sun Mi,Jang Mijung,Shin Sung Ui,Moon Woo Kyung 대한영상의학회 2024 Korean Journal of Radiology Vol.25 No.6

        Objective: To prospectively investigate the influence of the menstrual cycle on the background parenchymal signal (BPS) and apparent diffusion coefficient (ADC) of the breast on diffusion-weighted MRI (DW-MRI) in healthy premenopausal women. Materials and Methods: Seven healthy premenopausal women (median age, 37 years; range, 33–49 years) with regular menstrual cycles participated in this study. DW-MRI was performed during each of the four phases of the menstrual cycle (four examinations in total). Three radiologists independently assessed the BPS visual grade on images with b-values of 800 sec/mm2 (b800), 1200 sec/mm2 (b1200), and a synthetic 1500 sec/mm2 (sb1500). Additionally, one radiologist conducted a quantitative analysis to measure the BPS volume (%) and ADC values of the BPS (ADCBPS) and fibroglandular tissue (ADCFGT). Changes in the visual grade, BPS volume (%), ADCBPS, and ADCFGT during the menstrual cycle were descriptively analyzed. Results: The visual grade of BPS in seven women varied from mild to marked on b800 and from minimal to moderate on b1200 and sb1500. As the b-value increased, the visual grade of BPS decreased. On b800 and sb1500, two of the seven volunteers showed the highest visual grade in the early follicular phase (EFP). On b1200, three of the seven volunteers showed the highest visual grades in EFP. The BPS volume (%) on b800 and b1200 showed the highest value in three of the six volunteers with dense breasts in EFP. Three of the seven volunteers showed the lowest ADCBPS in the EFP. Four of the seven volunteers showed the highest ADCBPS in the early luteal phase (ELP) and the lowest ADCFGT in the late follicular phase (LFP). Conclusion: Most volunteers did not exhibit specific BPS patterns during their menstrual cycles. However, the highest BPS and lowest ADCBPS were more frequently observed in EFP than in the other menstrual cycle phases, whereas the highest ADCBPS was more common in ELP. The lowest ADCFGT was more frequent in LFP.

      • KCI등재

        The Value of Adding Ductography to Ultrasonography for the Evaluation of Pathologic Nipple Discharge in Women with Negative Mammography

        Choi Younjung,Kim Sun Mi,Jang Mijung,Yun Bo La,Kang Eunyoung,Kim Eun-Kyu,Park So Yeon,Kim Bohyoung,Cho Nariya,Moon Woo Kyung 대한영상의학회 2022 Korean Journal of Radiology Vol.23 No.9

        Objective: The optimal imaging approach for evaluating pathological nipple discharge remains unclear. We investigated the value of adding ductography to ultrasound (US) for evaluating pathologic nipple discharge in patients with negative mammography findings. Materials and Methods: From July 2003 to December 2018, 101 women (mean age, 46.3 ± 12.2 years; range, 23–75 years) with pathologic nipple discharge were evaluated using pre-ductography (initial) US, ductography, and post-ductography US. The imaging findings were reviewed retrospectively. The standard reference was surgery (70 patients) or > 2 years of followup with US (31 patients). The diagnostic performances of initial US, ductography, and post-ductography US for detecting malignancy were compared using the McNemar’s test or a generalized estimating equation. Results: In total, 47 papillomas, 30 other benign lesions, seven high-risk lesions, and 17 malignant lesions were identified as underlying causes of pathologic nipple discharge. Only eight of the 17 malignancies were detected on the initial US, while the remaining nine malignancies were detected by ductography. Among the nine malignancies detected by ductography, eight were detected on post-ductography US and could be localized for US-guided intervention. The sensitivities of ductography (94.1% [16/17]) and post-ductography US (94.1% [16/17]) were significantly higher than those of initial US (47.1% [8/17]; p = 0.027 and 0.013, respectively). The negative predictive value of post-ductography US (96.9% [31/32]) was significantly higher than that of the initial US (83.3% [45/54]; p = 0.006). Specificity was significantly higher for initial US than for ductography and post-ductography US (p = 0.001 for all). Conclusion: The combined use of ductography and US has a high sensitivity for detecting malignancy in patients with pathologic nipple discharge and negative mammography. Ductography findings enable lesion localization on second-look post-ductography US, thus facilitating the selection of optimal treatment plans.

      • SCISCIESCOPUS
      • KCI등재

        Automated Versus Handheld Breast Ultrasound for Evaluating Axillary Lymph Nodes in Patients With Breast Cancer

        Kim Sun Mi,Jang Mijung,Yun Bo La,Shin Sung Ui,Rim Jiwon,Kang Eunyoung,Kim Eun-Kyu,Shin Hee-Chul,Park So Yeon,Kim Bohyoung 대한영상의학회 2024 Korean Journal of Radiology Vol.25 No.2

        Objective: Automated breast ultrasound (ABUS) is a relevant imaging technique for early breast cancer diagnosis and is increasingly being used as a supplementary tool for mammography. This study compared the performance of ABUS and handheld ultrasound (HHUS) in detecting and characterizing the axillary lymph nodes (LNs) in patients with breast cancer. Materials and Methods: We retrospectively reviewed the medical records of women with recently diagnosed early breast cancer (≤ T2) who underwent both ABUS and HHUS examinations for axilla (September 2017–May 2018). ABUS and HHUS findings were compared using pathological outcomes as reference standards. Diagnostic performance in predicting any axillary LN metastasis and heavy nodal-burden metastases (i.e., ≥ 3 LNs) was evaluated. The ABUS-HHUS agreement for visibility and US findings was calculated. Results: The study included 377 women (53.1 ± 11.1 years). Among 385 breast cancers in 377 patients, 101 had axillary LN metastases and 30 had heavy nodal burden metastases. ABUS identified benign-looking or suspicious axillary LNs (average, 1.4 ± 0.8) in 246 axillae (63.9%, 246/385). According to the per-breast analysis, the sensitivity, specificity, positive and negative predictive values, and accuracy of ABUS in predicting axillary LN metastases were 43.6% (44/101), 95.1% (270/284), 75.9% (44/58), 82.6% (270/327), and 81.6% (314/385), respectively. The corresponding results for HHUS were 41.6% (42/101), 95.1% (270/284), 75.0% (42/56), 82.1% (270/329), and 81.0% (312/385), respectively, which were not significantly different from those of ABUS (P ≥ 0.53). The performance results for heavy nodal-burden metastases were 70.0% (21/30), 89.6% (318/355), 36.2% (21/58), 97.3% (318/327), and 88.1% (339/385), respectively, for ABUS and 66.7% (20/30), 89.9% (319/355), 35.7% (20/56), 97.0% (319/329), and 88.1% (339/385), respectively, for HHUS, also not showing significant difference (P ≥ 0.57). The ABUS–HHUS agreement was 95.9% (236/246; Cohen’s kappa = 0.883). Conclusion: Although ABUS showed limited sensitivity in diagnosing axillary LN metastasis in early breast cancer, it was still useful as the performance was comparable to that of HHUS.

      • KCI등재

        Reproducibility of Apparent Diffusion Coefficient Measurements in Malignant Breast Masses

        Jang, Mijung,Kim, Sun Mi,Yun, Bo La,Ahn, Hye Shin,Kim, Soo Yeon,Kang, Eunyoung,Kim, Sung-Won The Korean Academy of Medical Sciences 2015 JOURNAL OF KOREAN MEDICAL SCIENCE Vol.30 No.11

        <P>This study aimed to evaluate the reproducibility of apparent diffusion coefficient (ADC) measurements in malignant breast masses, and to determine the influence of mammographic parenchymal density on this reproducibility. Sixty-six patients with magnetic resonance findings of the mass were included. Two breast radiologists measured the ADC of the malignant breast mass and the same area on the contralateral normal breast in each patient twice. The effects of mammographic parenchymal density, histology, and lesion size on reproducibility were also assessed. There was no significant difference in the mean ADC between repeated measurements in malignant breast masses and normal breast tissue. The overall reproducibility of ADC measurements was good in both. The 95% limits of agreement for repeated ADCs were approximately 30.2%-33.4% of the mean. ADC measurements in malignant breast masses were highly reproducible irrespective of mass size, histologic subtype, or coexistence of microcalcifications; however, the measurements tended to be less reproducible in malignant breast masses with extremely dense parenchymal backgrounds. ADC measurements in malignant breast masses are highly reproducible; however, mammographic parenchymal density can potentially influence this reproducibility.</P>