YBa<sub>2</sub>Cu<sub>3</sub>O<sub>7</sub> 박막을 이용한 하이브리드형 초전도 사고전류제한기의 특성
최효상,조용선,Choi, Hyo-Sang,Cho, Yong-Sun 한국전기전자재료학회 2006 전기전자재료학회논문지 Vol.19 No.4
We present investigations of a hybrid type superconducting fault current limiter (SFCL), which consists of transformers and resistive superconducting elements. The secondary windings of the transformer were separated into several electrically isolated circuits and linked inductively with each other by mutual flux, each of which has a superconducting current limiting element of $YBa_2Cu_3O_7$ (YBCO) stripes as a current limiting element. Simple connection in series of the SFCL elements tends to produce ill-timed quenching because of power dissipation unbalance between SFCL elements. Both electrical isolation and mutual flux linkage of the elements provides a solution to power dissipation unbalance, inducing simultaneous quench and current redistribution of the YBCO films. This design enables to increase the voltage rating of SFCL with given YBCO stripes.
전압증가에 따른 자속구속형 초전도 한류기의 전류제한 및 회복특성 분석
최효상,오금곤,한태희,조용선,최명호,한영희,성태현,Oh, Kum-Gon,Han, Tae-Hee,Cho, Yong-Sun,Cho, Hyo-Sang,Choi, Myoung-Ho,Han, Young-Hee,Sung, Tae-Hyun 한국조명전기설비학회 2007 조명·전기설비학회논문지 Vol.21 No.8
자속구속형 초전도 한류기는 1차 권선과 초전도 소자가 직렬로 연결된 2차 권선을 갖는 변압기로 구성되어 있다. 이 초전도 한류기는 결선방향에 따라 감.가극 결선으로 나누어진다. 1차 권선과 2차 권선의 인덕턴스 비에 따라 자속구속형 초전도 한류기는 사고전류의 제한특성을 제어할 수 있다. 본 논문에서는 인가전압에 따른 자속구속형 초전도 한류기의 전압 전류 특성을 분석하였다. 감 가극 결선된 자속구속형 초전도 한류기의 인가전압을 증가시켰을 때, 초기에 제한되는 전류 및 초전도 소자의 ??치 시간은 증가하였다. 초전도 소자의 회복시간은 인가전압이 증가함에 따라 증가하였다. 그러므로 자속구속형 초전도 한류기의 회복특성은 초전도 소자의 소비전력이 증가하기 때문에 초전도 소자에서 소비되는 에너지에 크게 의존한다는 것을 확인할 수 있었다. The flux-lock type SFCL consists of transformer with primary and secondary windings connected to a superconducting element in serial. It can be divided into the subtractive and the additive polarity windings according to the winding direction. It could change the fault current limiting characteristics according to the inductance ratio between the coil 1 and coil 2. We investigated the voltage-current characteristics of the flux-lock type SFCL according to the increment of applied voltage. When the applied voltage of the SFCL with the subtractive and the additive polarity windings was increased a initial limiting current ($I_{ini}$) and the quench time of the superconducting element were increased. The recovery time of the superconducting element was increased by increment of applied voltage. Therefore, it was confirmed that recovery characteristics in the flux-lock type SFCL were largely dependent on the consumed energy of a superconducting element because of increment of the consumption power into the superconducting element.
최효상,Choi, Hyo-Sang 한국전기전자재료학회 2004 전기전자재료학회논문지 Vol.17 No.6
We present the basic properties of a superconductive fuse (SF) based on YBCO/Au films. The SF consists of YBCO stripes covered with Au layers for current shunt. The fault current was limited to a designed value in less than 0.4 msec by resistance development in YBCO/Au upon quenching. This enabled the SF to transfer small fault power and the suppressed current was sustained for more than 0.5 msec while Au layer melting and arcing. The arcing time was less than 2.5 msec, that is short enough to do self-interruption. Under the source voltage of 100 $V_{rms}$, the longer the duration time of fault current was, the shorter its discharge time was. The duration time of fault current and its discharge time were reduced by increased voltages in the range of 200 - 300 $V_{rms}$. We thought that this was because the quench propagation was limited by local melting generated with higher voltage.age.
최효상,현옥배,김혜림,황시돌,Choi, Hyo-Sang,Hyun, Ok-Bae,Kim, Hye-Rim,Hwang, Si-Dole 한국초전도저온공학회 2000 한국초전도저온공학회논문지 Vol.2 No.2
We fabricated a resistive superconducting fault current limiter (SFCL) of meander type based on a YBCO film. In order to disperse the heat generated at hot spots in the YBCO film the film was coated with a gold shunt layer. When diodes were inserted in the parallel circuit to restrict the temperature increase in the SFCL element by reducing power supply cycles, the voltage could be increased to $\sqrt{2}$ times with the same quench resistance at a half and full cycles.
직·병렬연결시 리액터를 이용한 초전도 소자의 퀜치 특성
최효상,임성훈,조용선,남긍현,이나영,박형민,Choi, Hyo-Sang,Lim, Sung-Hun,Cho, Yong-Sun,Nam, Gueng-Hyun,Lee, Na-young,Park, Hyoung-Min 한국전기전자재료학회 2005 전기전자재료학회논문지 Vol.18 No.9
We investigated quench characteristics of superconducting elements connected in series and parallel each other. The serial and parallel connections of superconducting elements causes a difficulty in simultaneous quench due to slight difference between their critical current densities. In other to induce simultaneous quench, we fabricated four type circuits; serially connected circuit before parallel connection, the circuit connected in parallel before serial connection, serially connected circuit before parallel connection with reactors, the circuit connected in Parallel before serial connection with reactors. We confirmed that the simultaneous quenches occurred in serial and parallel connections of superconducting elements using reactors. In addition, the power burden of superconducting elements was smaller than those of serial and parallel connections of superconducting elements without reactors.
최효상,이나영,이상일,Choi, Hyo-Sang,Lee, Na-Young,Lee, Sang-Il 한국전기전자재료학회 2005 전기전자재료학회논문지 Vol.18 No.9
We investigated the unbalanced characteristics of the superconducting fault current limiters (SFCLs) based on YBCO thin films with a single line-to-ground fault. When a single line-to-ground fault occurred, the short circuit current of a fault phase increased about 6 times of transport currents after the fault onset but was effectively limited to the designed current level within 2 ms by the resistance development of the SFCL. The fault currents of the sound phases almost did not change because of their direct grounding system. The unbalanced rates of a fault phase were distributed from 6.4 to 1.4. It was found that the unbalanced rates of currents were noticeably improved within one cycle after the fault onset. We calculated the zero phase currents for a single line-to-ground fault using the balanced component analysis. The positive sequence resistance was reduced remarkably right after the fault onset but eventually approached the balanced positive resistance component prior to the system fault. This means that the system reaches almost the three-phase balanced state in about 60 ms after the fault onset at the three-phase system.