합곡(合谷) 및 족삼리(足三里) 혈(穴) 자침이 인영혈(人迎穴)부위의 뇌혈류에 미치는 영향
이충식 ( Chung Sik Lee ),박보라 ( Bo Ra Park ),서종훈 ( Jong Hoon Seo ),강형원 ( Hyung Won Kang ),류영수 ( Yeoung Su Lyu ),김태헌 ( Tae Heon Kim ) 대한한방신경정신과학회 2007 동의신경정신과학회지 Vol.18 No.1
Objective : This study was performed to evaluate the effects of Hap-Kok(LI4) and Jok-Sam-Lee(ST36) acupuncture on blood flow in In-Young(ST9). Method : Monitoring of TCD was examined in each 25`s healthy men and wemen in 20s before and after acupucture on both(right and left) Hap-kok(LI4) and was done on both(right and left) Jok-Sam-Lee(ST36) by different group with same condition. Mean velocity and Pulsatility index analyzed from TCD at both In-Young(ST9). Both group was acupuctured for 15-20 minutes laying at bed. Results : The results showed a significant(p≤0.05: Paired T-test) decrease in mean velocity and increase in pulsatility index at both group. Conclusion : These results suggest that acupuncture could have a specific effect on blood flow called In-Young acupoint.
BIPV 시스템의 차양 효과에 따른 피크 냉방부하 절감효과에 관한 연구
이충식(Lee Chung-Sik),이응직(Lee Eung-Jik),이철구(Lee Chul-Goo) 한국태양에너지학회 2008 한국태양에너지학회 논문집 Vol.28 No.5
As the number of buildings that use the transparent permeation materials as the outer wall is on the increase, the coming amount of the light rays is a lot, and thus the increase in the cooling load and the radiant heat of high temperature may cause the residents to discomfort. In order to reduce such influences, this paper analyzed the installation effects of the sunshade BIPV. The inner temperature of the room installed the sunshade BIPV or otherwise was measured, and compared and analyzed the effects of reducing the cooling load by the incoming light rays. The sample space of the third floor of S university installed the sunshade BIPV has two rooms on the same conditions, and for five sunny days selected in August, the researcher measured the air temperature and the temperature of the fittings with closing the windows to minimize the movement of air without operating the coolers. The maximum cooling load measured by the incoming light rays in the room where the sunshade BIPV was not installed was examined as 459.13kcal/h. It can be understood as the effect of reducing the cooling load according to the incoming rays of the room with sunshade BIPV. Even though the effect of cooling load reduction is not so great in a room, the total reduction in cooling room for the 32 rooms installed the sunshade BIPV was estimated to be 40442.27kcal/day, which will be able to bring the maximum reduction effect of 17.lkW in energy and reduce the investment cost owing to the reduction in cooling load when initially designing the building.