http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
정관성,이동규,이근우,오원진,정종헌,박진호,Jeong Kwan-Seong,Lee Dong-Gyu,Lee Kune-Woo,Oh Won-Zin,Jung Chong-Hun,Park Jin-Ho 한국방사성폐기물학회 2006 방사성폐기물학회지 Vol.4 No.2
Decommissioning cost estimation is a very important technique in designing and planning of nuclear facilities' decommissioning. Decommissioning cost estimation should be made according to the phases of decommissioning activities and installed components of nuclear facilities. In this paper, the basic framework necessary for decommissioning cost estimation is completed so that it could be used as a technique for decommissioning costs estimation by specifying cost items and group components and unit cost factors on which work time is calculated. Also, factors to be considered for decommissioning cost estimation of major activities and tasks are reviewed. Afterwards, these techniques will be utilized as a basic technology to establish methodology of decommissioning cost estimation and evaluation.
정관성,이동규,정종헌,이근우,Jeong, Kwan-Seong,Lee, Dong-Gyu,Jung, Chong-Hun,Lee, Kune-Woo 한국방사성폐기물학회 2006 방사성폐기물학회지 Vol.4 No.4
The estimated decommissioning cost of nuclear research reactor is calculated by applying a unit cost factor-based engineering cost calculation method on which classification of decommissioning works fitted with the features and specifications of decommissioning objects and establishment of composition factors are based. Decommissioning cost of nuclear research reactor is composed of labor cost, equipment and materials cost. Labor cost of decommissioning costs in decommissioning works are calculated on the basis of working time consumed in decommissioning objects. In this paper, the unit cost factors and work difficulty factors which are needed to calculate the labor cost in estimating decommissioning cost of nuclear research reactor are derived and figured out.
정관조(Gwan Jo Jeong),이경우(Kyung Woo Lee),김복순(Bog Soon Kim),이수원(Su Won Lee),이종규(Jong Gyu Lee),구아미(A Mi Koo) 大韓環境工學會 2014 대한환경공학회지 Vol.36 No.11
인공방사성핵종 I-131은 물속에서 요오드 이온(131I-), 요오드산염 이온(131IO₃-) 등 대부분 이온상태로 존재했으며 접촉시간이 짧을 경우, 정수약품(PACl)과 분말활성탄(PAC)에 의해 제거되지 않는 것으로 나타났다. 원수 탁도 증가에 따른 I-131의 제거 효과는 없었으나 분말활성탄과 I-131과의 접촉시간 증가에 따른 I-131의 제거율은 증가하는 것을 확인하였다. 혼합주입(PACl + PAC)에 의한 I-131을 40% 이상 제거하기 위해서는 PACl 24 mg/L 이상, PAC 40 mg/L 이상을 주입해야 하는 것을 알 수 있었다. 모래여과에 의한 I-131은 제거되지 않은 것으로 나타났으며, 입상활성탄(GAC)에 의한 제거율은 신탄, 구탄모두에서 최소검출한계 0.10 Bq/L 미만으로 거의 100% 제거됨을 알 수 있었다. 막에 의한 I-131의 제거율은 정밀여과막에의해서는 제거되지 않았으며 역삼투막에서는 92%가 제거되었다. Iodine-131, an artificial radionuclide, mostly exists as iodide ion (131I-) and iodate ion (131IO₃-) in the water, andWhen a short time contacted, it could not be removed by poly aluminum chloride (PACl) and powdered activated carbon (PAC). Although the removal rate of iodine-131 was not related with turbidity of raw water, it showed linear relationship with contacttime with PAC. With the mixture of PACl (24 mg/L or more) and PAC (40 mg/L or more), about 40% of iodine-131 could beremoved. Iodine-131 could be removed little by sand filtration, but approximately 100% by granular activated carbon (GAC), bothvirgin-GAC and spent-GAC. Microfiltration process could remove little iodine-131 while reverse osmosis process could remove about92% of iodine-131.
갱생 옥내급수관 수돗물에서 비스페놀-A 분포 및 위해성 평가
정관조(Gwanjo Jeong),손보영(Boyoung Son),이인자(Inja Lee),안치화(Chihwa Ahn),김준일(Junil Kim),문보람(Boram Moon),이수원(Suwon Lee),안재찬(Jaechan Ahn),김복순(Bogsoon Kim),정득모(Deukmo Chung) 대한환경공학회 2016 대한환경공학회지 Vol.38 No.7
본 연구에서는 에폭시 수지 갱생 옥내급수관 수돗물에 대해 비스페놀-A 실태조사를 실시하였고, 비스페놀-A가 수돗물 음용에 있어 인체에 미치는 영향을 파악하기 위해 위해성 평가를 실시하였다. 원수 중 비스페놀-A는 50~118 ng/L로 채취된 모든 시료에서 정량한계 10 ng/L 이상으로 검출되었다. 이것은 주변지역의 하수 방류수나 지천에 의한 비스페놀-A 유입에 의한 것으로 판단된다. 정수에서의 비스페놀-A는 불검출되었으며, 고도정수처리 공정에서 모두 제거된 것으로 추정되었다. 응집-침전과정과 오존 및 염소에 의해 산화되어 제거되거나 다른 산화 부산물질로 변화한 것으로 판단된다. 옥내급수관 수돗물의 경우, 에폭시 갱생공사를 실시하지 않은 수돗물 모두에서 비스페놀-A는 검출되지 않았다. 그러나 에폭시 갱생공사를 실시한 옥내급수관 수돗물에서 비스페놀-A가 불검출에서 최대 521 ng/L로 범위로 검출되었으며, 채취된 시료의 68%가 정량한계 이상으로 검출되었다. 검출된 비스페놀-A의 최대값(521 ng/L)에 대한 위해도 지수 산정 결과, 위해도 지수(HQ)는 약 0.004로 수돗물 섭취에 의한 위해판단 기준값 0.1 이하로 나타나 음용에 안전한 것을 확인하였다. In this study, the survey of bisphenol-A in indoor water service pipes rehabilitated with epoxy resin was conducted and the risk assessment was done to investigate the effect on the human health to drink tap water. Bisphenol-A in raw water was detected in a range of 50~118 ng/L in all samples, where the limit of quantification was 10 ng/L. This is caused by inflow of the sewage effluent or the tributaries of the surrounding area containing bisphenol-A. Bisphenol-A was not detected in finished water after the advanced water treatment process. It was achieved by its removal from the processes of flocculation-precipitation and oxidation of ozone and chlorine and by being changed to other by-product materials. For the indoor water service pipe, bisphenol-A was not detected in all cases which was not coated with epoxy resin. However, when epoxy resin is lined within the indoor water service pipe, bisphenol-A was identified at maximum level of 521 ng/L and was detected above the limit of quantitation at 68 percentages of all samples. The Hazard Quotient (HQ) at the maximum level (521 ng/L) of the detected bisphenol-A is 0.004, which is less than the reference value of 0.1 for the tap water intake. Therefore, it is considered that the detected levels of bisphenol-A in this study would be safe to drink tap water.
하수관망의 간소화가 도시침수 모의에 미치는 영향 분석에 관한 연구
이승수,정관수,김연수,Lee, Seung-Soo,Pakdimanivong, Mary,Jung, Kwan-Sue,Kim, Yeonsu 한국수자원학회 2018 한국수자원학회논문집 Vol.51 No.4
도시유역에서 발생한 유출은 지표면뿐만 아니라 하수관망을 통해 배수되며, 도시침수 모의 수행시 하수관망을 수문학적 배수 시스템의 한 구성요로서 고려하는 것은 매우 중요하다. 그러나 도시 침수 모의를 수행하는 대부분의 연구자들이 적절한 기준에 준하지 않고 직관적으로 하수관망을 단순화시켜 모의를 수행하는 실정이다. 따라서 본 연구에서는 1D-2D 결합 도시침수 해석 모형을 이용하여 수지상 구조에 구분법에 기반하여 단순화된 하수관망의 도시침수 해석 결과에 미치는 영향을 분석하였다. 하수관망 해석을 위한 1차원 모델은 Lee et al. (2017)에 의해 소개된 모형으로서 지표면과 하수관망 사이의 유입과 역류를 동시에 모의할 수 있고, 2차원 지표면 모델은 불규칙 삼각망을 이용하여 지표수 흐름을 모의하며 1차원 하수관망 해석모형과 연계되어 도시침수를 모의할 수 있다. 하수관망은 수지상 구조 구분법에 기반하여 2차, 3차 그리고 단순화 하지 않은 경우로 구분할 수 있으며, 구분된 각 하수관망은 서울시 사당역 인근에 많은 침수 피해를 발생시킨 2011년 7월 27일 강우 사상에 적용하여 제안된 방법의 적용성을 평가하였다. 모든 케이스에 대하여 침수면적, 지표면에서 하수관망으로의 유입 유량, 하수관망에서 지표면으로의 역류 유량 등을 비교하였으며, 마지막으로 하수관망 단순화를 위한 적절한 기준 제시에 대한 논의를 수행하였다. In urban areas, runoff flow is drained through sewer networks as well as surface areas. Therefore, it is very important to consider sewer networks as a component of hydrological drainage processes when conducting urban inundation modelling. However, most researchers who have implemented urban inundation/flood modelling, instinctively simplified the sewer networks without the appropriate criteria. In this research, a 1D-2D fully coupled urban inundation model is applied to estimate the influence of sewer network simplification on urban inundation modelling based on the dendritic network classification. The one-dimensional (1D) sewerage system analysis model, which was introduced by Lee et al. (2017), is used to simulate inlet and overflow phenomena by interacting with surface flow. Two-dimensional (2D) unstructured meshes are also applied to simulate surface flow and are combined with the 1D sewerage analysis model. Sewer network pipes are simplified based on the dendritic network classification method, namely the second and third order, and all cases of pipes are conducted as a control group. Each classified network case, including a control group, is evaluated through their application to the 27 July 2011 extreme rainfall event, which caused severe inundation damages in the Sadang area in Seoul, South Korea. All cases are compared together regarding inundation area, inflow discharge and overflow discharge. Finally, relevant criterion for the simplification method is recommended.