http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
광전식감도시험기의 발광부와 수광부 작동원리에 관한 연구
윤헌주(Yoon, Hun-Ju),권성필(Kwon, Seong-Pil),김형권(Kim, Hyeong-Gweon),사공성호(SaKong, Seong-Ho) 한국화재소방학회 2008 한국화재소방학회 학술대회 논문집 Vol.2008 No.춘계
The advanced technical data collected from home and abroad have properly been analyzed, so that they are useful to improve the photoelectric sensitivity tester. The results of this study have quickly been supplied to the related industry. Our research and development team has verified the response characteristics of the light-emitting and -receiving part of the photoelectric sensitivity tester in order to help the local manufacturer to study, develope and produce their photoelectric detectors.
신생혈관녹내장에서 항대사제를 병용한 아메드 장치 삽입술의 수술 성공률 평가
윤헌주,박준정.Heon Ju Yoon. MD. Jun Jeong Park. MD 대한안과학회 2010 대한안과학회지 Vol.51 No.2
Purpose: To evaluate the outcome after Ahmed valve implantation in patients with neovascular glaucoma when using intraoperative mitomycin C (MMC) and postoperative 5-fluorouracil (5-FU). Methods: A total of 40 eyes of 40 patients with neovascular glaucoma who received antiglacomatous medication without previous glaucoma surgery were included in the present study. The patients received Ahmed valve implantation and intraoperative MMC and postoperative 5-FU. Failure was defined as the first occurrence of any of the following: 1) the first of three consecutive visits where intraocular pressure (IOP) was >18 mmHg or 20% IOP reduction from baseline and the final number of topical medication did not reduce by at least two from baseline, 2) the need for additional surgery, or 3) the occurrence of a serious complication. Results: The cumulative success rate was 77.5% at 12 months. The final number of topical medication after Ahmed valve implantation was 0.73±0.78, and the change in the number of medication from baseline was -2.18±0.84. Serious complications such as endophthalmitis, valve exposure or prolonged hypotony were not observed . Conclusions: The adjunctive use of intraoperative MMC and postoperative 5-FU with Ahmed valve implantation results in a high success rate and good IOP control and did not show serious complications within the postoperative period. J Korean Ophthalmol Soc 2010;51(2):227-233
혈청 anti - HCV 양성자의 역학 및 가족내 감염과 HBV 표지자에 관한 조사
이헌주(Heon Ju Lee),강호정(Ho Jung Kang),김기덕(Kee Duck Kim),박찬원(Chan Won Park),윤현대(Hyun Dae Yoon),전진종(Jin Chong Chun),최교원(Kyo Won Choi),최희진(Hee Jin Choi) 대한내과학회 1992 대한내과학회지 Vol.43 No.6
Background: Transfusion is a well-known source of hepatitis C virus (HCV) infection but over half of the hepatitis C patients do not have any suspicious source of infection. Epidemiological survey and serological test for HBV marks were done among anti-HCV positive chronic liver disease patient and their family members. Method: 74 cases of anti-HCV postitive chronic liver disease patients were evaluated for the evident source of HCV infection and 188 of their family members were consulted for the infection of HCV. To compare the mode of HBV infection with HCV, serum HBsAg, anti-HBc and anti-HBs were checked in 43 of HBsAg positive chronic liver disease patients, 190 of their family members, 64 anti-HCV postive chronic liver disease patients and 239 of normal control persons. Results: 35cases (47.3%) of 74 anti-HCV positive chronic liver disease patients had no suspicious source of infection and only 16 cases (21.6%) had the history of past transfusion. No family members except 3 (one infant, one IV drug abuser and one wife) in 3 families among 74 families were anti-HCV positive. 29 of 43 (67. 4%) families of HBsAg positive chronic liver disease patients had at least one of HBsAg positive member. Characteristically, HBsAg was positive in almost all cases of offsprings born to mothers of HBsAg and HBeAg positive chronic liver disease. 2 of 64 (3.1%) serum anti-HCV positive patients had HBsAg in their sera. Anti-HBs positive cases were 11 of 64 (17.2%.) anti-HCV positive chronic liver disease patients and isolated anti-HBc positive cases were 40 of 64 (62.5%). On the other hand, in normal control, the positive rate of anti-HBs and isolated anti-HBc were 57,4% and 24.3%(> in each (p<0,005, in both). Conclusion: In Korea, vertical transmission was the main source of HBV infection but HCV disease might be horizontal and sporadic. No remarkable difference in HBV infection rate between anti-HCV positive chronic liver disease patients and control persons. Superinfection of HCV on person who already was exposed to HBV may occur but this assumption could be depend on accurate testings for HBV and HCV. Some derangement in immune system and reaction or interaction between HBV and HCV should be considered in anti- HCV positive patients but before, isolated serum anti- HBc positive sera of chronic liver disease patients should be examined by confirmatory tests. To reduce the number of HCV patients, defining the evident source of the sporadically infected HCV cases could be helpful.
이헌주(Heon Ju Lee),이현우(Hyun Woo Lee),윤봉영(Bong Young Yoon),김종명(Jong Myung Kim),김정회(Jung Hee Kim),곽철승(Chul Sung Kwak) 대한소화기학회 1989 대한소화기학회지 Vol.21 No.2
N/A Evaulation of serum bile acids has been used for prediction of abnormal serum liver profile in the world. But recently many reported that bile acids in a random sample of urine (URNBA), corrected for urine flow with creatinine, have high diagnostic value when compared with serum bile acid and routine serum liver tests. We analyzed URNBA as a predictor of liver abnormality in 27 subjects of various liver disease and 8 normal subjects and compared with the results of serum bile acids and routine serum liver profile. In the patients, the rates of abnormal elevation of URNBA and serum bile acid were 85.2% (23/27) and 74.1% (20/27), respectively. URNBA/creatinine in the random sample of urine revelaed the highest reliability that reflects the presence of liver disease. So we think that urine can be used to predict liver diasese with an accurary that equals or exceeds the serum bile acid and the routine liver tests.
권성필(Kwon, Seong-Pil),윤헌주(Yoon, Hun-Ju),김형권(Kim, Hyeong-Gweon),라용운(Ra, Yong-Woon),사공성호(SaKong, Seong-Ho),신동일(Shin, Dong-Il) 한국화재소방학회 2008 한국화재소방학회 학술대회 논문집 Vol.2008 No.추계
In this work wood crib burning behaviors have been simulated by using the FDS(Fire Dynamic Simulator) program. Wood cribs are regularly stacked arrays of wood sticks, and available for the performance rating of fire-extinguishers. On the basis of an angle iron supporter 26 layers of wood sticks have been stacked up. Each layer consists of 5 or 6 wood sticks which are placed in parallel, with a constant distance, and in alternating rows. They are laid between the horizontally adjacent sticks at the before last layer. The wood crib is ignited instantaneously by an amount of burning gasoline below. A comprehensive simulation of such a practical sophisticated combustion is still too difficult to realize with any currently available computer, although the performance of modern processors is getting better everyday. We could carry it out here through parallel computing on the HPC(High Performance Computing) cluster as the feasible alternative. At last the validation has been executed by means of temperature distribution data measured by the thermal video camera.
김형권(Kim, Hyeong-Gweon),윤헌주(Yoon, Hun-Ju),권성필(Kwon, Seong-Pil),사공성호(SaKong, Seong-Ho),백창선(Back, Chang-Sun) 한국화재소방학회 2008 한국화재소방학회 학술대회 논문집 Vol.2008 No.춘계
In this study we compared corrosion resistance tests which were carried out according to the national technique standard and the UL standard to ensure the reliability of smoke detectors in foul weather. The sensitivity of smoke detectors became so blunt that the least operational smoke concentration was a maximum change of 13% in the national technique standard, while it was a maximum change of 145% in the UL standard. As a result of this study the test method of corrosion resistance was made an objective evaluation in the national technique standard. Therefore it could be said that a basis of developing the test method of corrosion resistance was prepared for our country.
김형권(Kim, Hyeong-Gweon),권성필(Kwon, Sung-Pil),윤헌주(Yoon, Hun-Ju),사공성호(Sakong, Seong-Ho) 한국화재소방학회 2009 한국화재소방학회 학술대회 논문집 Vol.2009 No.춘계
소방대상물에 기 설치되어 있는 연기감지기에 대한 정밀한 감지 성능 시험의 요구에 부응하기 위하여 현장에서 국내 기술기준에 적합하게 시험할 수 있는 휴대용 연기감도 시험기에 대하여 연구하였다. 휴대용 연기감도시험기는 점검 현장에서 간이로 감도시험을 할 수 있도록 연기원으로 동양 2호지를 사용하여 연기를 발생시키고, 농도를 제어하고 일정풍속 유지가 가능하여 현장에 설치된 연기감지기의 정밀한 시험이 가능하도록 하였다.
권성필(Kwon, Seong-Pil),김형권(Kim, Hyeong-Gweon),윤헌주(Yoon, Heon-Joo),리용운(Ra, Yong-Woon),손윤석(Sohn, Yoon-Suk),신동일(Shin, Dong-Il) 한국화재소방학회 2009 한국화재소방학회 학술대회 논문집 Vol.2009 No.춘계
본 연구에서는 친환경 인테리어용으로 개발된 벽포지에 대해 방염성능이 시험되었다. 실제로 방염성능은 "45<TEX>$^{\circ}$</TEX> 연소시험" 및 "접염시험", 그리고 "연기밀도시험"에 의해서 수행되었다. 벽포지의 주성분이 고온에서 쉽게 용융하는 PET(폴리에스터) 이다. PET의 이런 물성으로 인하여 "45<TEX>$^{\circ}$</TEX> 연소시험"과 "연기밀도시험"의 요구조건들은 쉽게 만족시킬 수 있었지만, 용융 물품에 대해 추가로 요구되는 "접염시험"은 통과하기 어려웠다. 총 47종 109점에 대해 방염성능시험을 수행한 결과 18종 54점이 요구조건을 만족하였다. 일반적으로 보드에 배접된 상태로 시공되는 모듈의 난연성능을 개선하기 위해서는 벽포지의 방염성능뿐만 아니라 보드, 접착제 등의 특성에 관한 보다 많은 연구가 필요하다.
권성필(Kwon, Seong-Pil),김형권(Kim, Hyeong-Gweon),윤헌주(Yoon, Hun-Ju),사공성호(SaKong, Seong-Ho) 한국화재소방학회 2008 한국화재소방학회 학술대회 논문집 Vol.2008 No.춘계
A standard fire extinguishing tester, with which we could conduct the fire extinguishing ability rating of a water-based fire extinguishing agent such as water and loaded stream, has been developed in this work. It could help us enhancing the efficiency and reliability of the fire extinguishing test of loaded streams, and at last increasing the productivity of fire protection related firms. Furthermore, our country could take the lead in making a new standard for the fire extinguishing test of loaded streams. As a result, it is expected that loaded streams could be improved by using it. In addition the standard fire extinguishing tester could be made moderately in our industry, and supplied at home and worldwide.