http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
박수란(Soo-Ran Park),박양호(Yang-Ho Park),박영주(Young-Ju Park),박준우(Jun-Woo Park),이용찬(Yong-Chan Lee),안병근(Byoung-Keun Ahn) 대한구강악안면외과학회 2002 대한구강악안면외과학회지 Vol.28 No.4
In order to improve the success rate of implants, various implant designs have been developed. Although there have been enough efforts to handle the surface of the implant with careful choice of material and mechanics so that the bone and the implant can be tightly joined together, they have still failed to play the role of periodontal ligaments of the natural teeth in the past. The role of periodontal ligaments is very important since it can improve the initial stability of implant by absorbing the impacts. The purpose of this study is, thus, to test the possibility of alleviating the impact when the surface of the implant was coated with chitosan, a natural polymer, and making sure that the coated material stayed on. Then, the condition of newly developed bone formation and the degree of inflammation in response was closely observed in the surface level. In the main experiment, Chitosan coated implant (3.3 mm×7mm) was implanted on both the right and the left side of rabbit’s femur. The animals were each sacrificed on the 1st, 2nd, 3rd, 7th, 14th, 21st and 28th day. The process was observed under an light microscope after the Toluidin Blue staining. From the experiment, it was found that the chitosan was evenly distributed on the surface of the screws, and the implant was adjoined with adjacent bone. There was a sign of inflammation on the 3rd day, but on the 14th day, the formation of woven bone and newly formed bones were noticed. Also, chitosan filled the gap was formed between the implant and the newly formed bone. The implant, the chitosan and the newly formed bone were forming one unit as a result. Therefore, it was found that chitosan coated implant could absorbe the impact in the initial stage of implant.
응급과 긴급 자궁경부 원형결찰술을 시행한 임신부에서 조기분만 예측 인자로서 수술 후 측정한 자궁경부 길이의 유용성
박수예 ( Soo Ye Park ),최수란 ( Soo Ran Choi ),이혜란 ( Hea Ran Lee ),양성천 ( Sung Cheon Yang ),이용우 ( Yong Woo Lee ),송지은 ( Ji Eun Song ),문종수 ( Jong Soo Moon ),김성주 ( Seong Joo Kim ),이근영 ( Keun Young Lee ) 대한산부인과학회 2011 Obstetrics & Gynecology Science Vol.54 No.9
목적: 응급과 긴급 자궁경부 원형결찰술을 시행 받는 임신부에서 임신 30주 이전 조기분만을 예측할 수 있는 예측인자로서 수술 후 질식초음파를 이용하여 측정한 자궁경부 길이의 유용성을 알아보고자 하였다. 연구방법: 자궁경부가 개대 되고 양막이 질쪽으로 탈출되어 응급 자궁경부 원형결찰술을 시행한 51명과 초음파상 자궁경부 내구의 깔대기모양 변화와 더불어 자궁경부 길이가 25 mm 미만으로 짧아져 긴급 자궁경부 원형결찰술을 시행한 40명을 대상으로 후향적으로 연구하였다. Receiver-operating characteristic (ROC) curve 분석, Pearson`s partial correlation coefficient와 다중로지스틱회귀분석을 사용하여 통계학 적으로 분석하였다. 결과: 입원당시 평균 임신 주수는 응급 자궁경부 원형결찰술을 시행한 군은 21.2 ± 2.3주 긴급 자궁경부 원형결찰술을 시행한 군은 21.8 ± 3.2 주이었다. 수술 후 측정한 자궁경부 길이는 응급 자궁경부 원형결찰술군은 17.6 ± 8.6 mm, 긴급 원형결찰술 군은 21.8 ± 8.7 mm로 증가하였다. ROC curve 분석에서 응급 자궁경부 원형결찰술군은 자궁경부 길이를 16.5 mm로 기준할 때, 민감도 85%, 특이도 50%, 양성예측도 17%, 음성예측도 16%, 긴급 자궁경부 원형결찰술군은 수술 후 자궁경부의 길이를 23.2 mm로 기준할 때, 민감도 65%, 특이도 45%, 양성예측도 17%, 음성예측도 8%이었다. 다중로지스틱회귀분석 결과, 수술 후 측정한 자궁경부 길이는 교란인자 보정 후 임신 30주 이전 조기분만과 독립적인 상관관계가 없었다(응급 원형결찰술군 P = 0.65, 긴급 원형결찰술군 P = 0.77). 결론: 응급과 긴급 자궁경부 원형결찰술 후 질식초음파를 이용하여 측정한 자궁경부의 길이는 증가하였으나, 임신 30주 이전 조기분만을 예측할 수 있는 유용한 인자는 아니다. Objective: The aim of this study is to evaluate the value of the ultrasonographic cervical length after emergent and urgent cervical cerclage to prediction of preterm delivery in patients with incompetence of cervix. Methods: Fifty-one women who underwent emergent cervical cerclage and forty women who underwent urgent cervical cerclage were studied respectively. Receiver-operating characteristic (ROC) curve analysis, Pearson`s partial correlation coefficient, and multiple logistic regression analysis were used for statistical analysis. Results: The mean gestational age at admission was 21.2 ± 2.3 weeks in emergent cerclage group and 21.8 ± 3.2 weeks in urgent cerclage group. Postoperative mean cervical length was 17.6 ± 8.6 mm in emergent group and 21.8 ± 8.7 mm in urgent group. The diagnostic indices of postoperative cervical length (cut-off value 16.5 mm in emergent cerclage, 23.2 mm in urgency cerclage) by ROC curve were sensitivity of 65%, specifi city of 45%, positive predictive value of 17%, and negative predictive value of 8% in emergent cerclage group and in urgent cerclage group, sensitivity of 85%, specifi city of 50%, positive predictive value of 17%, and negative predictive value of 16%. Multiple logistic regression analysis indicated that postoperative cervical length was not an independent predictor of preterm delivery after adjustment of confounding factors in emergent group (P=0.65) in urgent groups (P=0.77). Conclusion: In the both groups, the postoperative cervical length was longer than preoperative. However the postoperative cervical length is not a useful predictor of preterm delivery in patients with emergent and urgent cervical cerclage.
박수인 ( Su-in Park ),김인수 ( In-soo Kim ),김경민 ( Kyung-min Kim ),신소정 ( So-jung Sin ),서민태 ( Min-tae Seo ),김경란 ( Kyung-ran Kim ) 한국농공학회 2020 한국농공학회 학술대회초록집 Vol.2020 No.-
축산 스마트팜은 스마트기술 및 자동화 설비를 이용하여 원격으로 가축의 생육환경을 유지·관리하는 시스템이며 스마트 핵심 기술 중 ‘센서 및 계측’ 기술을 구현하기 위해서는 필수적으로 전자 장치가 사용된다. 한돈의 경우 정확한 환경 정보를 수집하고 자동제어 시스템을 구축하기 위해 사육환경 내에 상시측정이 가능한 측정 장치의 설치가 요구되나, 사육환경은 부식성 가스와 높은 습도, 분진이 발생하는 환경적 특성을 지니고 있다. 이로 인해 환경 모니터링 시스템 측정 전자 장치에 부식이 발생하여 이에 대한 내구성 확보가 개선 과제로 제안된 바 있다. 이에 본 연구는 돈사 사육환경에서 측정 전자 장치의 부식 현상을 분석하고, 개선안의 방향성을 제시하기 위해 전자장치의 핵심부품인 기판(PCB; Printed Circuit Board)를 실험대상으로 선정하여 실험을 수행하였다. 이를 위해 사육환경과 분뇨처리장에서 장시간 실사용 중 오동작이 발생한 온습도, 유해가스 측정 전자 장치의 PCB를 불량 분석하였고, 이를 토대로 상호 비교를 위한 PCB를 제작 하였다. 제작된 PCB는 전남 영광군의 상업용 돈사의 무창돈사 돈방 1개소에 거치하였으며 7월부터 10월까지 107일 동안 3주 간격으로 실험돈사를 방문하여 부식발생 및 진행여부를 점검하였다. 분석방법은 PCB를 절단한 뒤 절단면을 촬영하여 이상여부를 확인 하는 Cross-Section과 고화질 촬영 및 조성성분을 확인하는 SEM/EDS 분석을 활용하였다. 실험 결과 기존 문제가 발생한 측정 전자 장치와 모니터링 대상 PCB 모두 이물질 오염부를 중심으로 Solder(땜납) 및 Cu Pad Corrosion이 발생하였고, Through Hole Via(관통형 비아) 경우 부식으로 인한 PCB노출(단선)이 발생하였다. 부식부와 부식 산화물에서는 공통적으로 황(S)이 검출되었다. 본 연구에서는 한돈 사육 환경 내에서 전자 장치의 핵심부품인 PCB를 대상으로 발생하는 부식현상에 대한 분석 결과를 제시하였으며, 관련 기기설계의 기초자료로 활용되기를 기대한다.
실리카 2층 Slab 도파로를 위한 고유방정식의 개선된 알고리즘
지유강,박종란,윤중현,박수봉,Ji yoo-kang,Park jong-ran,Yun jung-hyun,Park soo-bong 대한전자공학회 2006 電子工學會論文誌-SD (Semiconductor and devices) Vol.43 No.2
본 논문에서는 실리콘 상의 2층 실리카 도파로에서 새로운 고유치 방정식을 도출하여, 프리즘 커플러로 굴절률과 박막의 두께를 결정하는 방법을 나타내었다. 도출된 고유치 방정식의 알고리즘은 반복 파라메터가 4개의 변수에서 3개의 변수로 감소되어질 수 있으므로 Ref.[5]의 방정식의 해보다 보다 좋은 장점을 갖으며. 또한 본 논문에 얻어진 평균 에러는 약 $10^{-5}\~10^{-6}$ 이 하였다. In this paper, we derive a novel eigenvalue equation of double silica layers on silicon only for TE mode and present the method as an example how to use it to determine the refractive indices and thicknesses with prism coupler. Our method to solve eigenvalue equation have good merit rather than [5] in that the equation is real and iteration parameters can be reduced from four to three. The average magnitude of the errors is less than $10^{-5}\~10^{-6}$ approximately