http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김강민,정수련,김상윤,김동중,김준성,임청,박계현 대한흉부외과학회 2018 Journal of Chest Surgery (J Chest Surg) Vol.51 No.4
Background: Limited comparative data are available on the efficacy of cryoablation versus radiofrequency ablation in patients with atrial fibrillation. This study aimed to compare radiofrequency ablation and cryoablation with regard to clinical outcomes and the restoration of sinus rhythm or atrial contractility. Methods: A total of 239 patients who underwent surgical ablation between August 2003 and December 2016 at our institution were included. The patients were divided into 2 groups according to the energy device that was used (group A: n=140, radiofrequency ablator; group B: n=99, cryoablator). Echocardiographic data, overall survival, and major cardiovascular and cerebrovascular event (MACCE)-free survival were compared between the 2 groups. Results: At 1 year of follow-up, the atrial contractility recovery rate was 32.2% (19 of 59) in group A and 48.8% (21 of 44) in group B. In addition, cryoablation was found to be a predictive factor for the recovery of atrial contractility (cryoablation vs. radiofrequency ablation: odds ratio, 2.540; 95% confidence interval, 1.063–6.071; p=0.036). The left ventricular ejection fraction was significantly higher in group B (53.1%±11.5% vs. 59.1%±6.3%, p=0.001). The median follow-up duration was 36 months. The 5-year overall survival rate was 80.1%±3.6% in group A and 92.1%±2.9% in group B (p=0.400). The 5-year MACCE-free survival rate was 70.3%±4.0% in group A and 70.9%±5.6% in group B (p=0.818). Conclusion: Cryoablation was associated with a higher atrial contractility restoration rate and better left ventricular function than radiofrequency ablation. However, no significant relationship was observed between the energy source and overall or MACCE-free survival.
김강민,이병철,한인우,윤태석,Kim, Kang-Min,Lee, Byeong-Chul,Han, In-Woo,Yoon, Tae-Seog 한국천문학회 2003 天文學論叢 Vol.18 No.1
We tested the characteristics of the newly made Long Slit Spectrograph (LSS) of the BOAO which replaced the Medium Dispersion Spectrograph (MDS) in the year of 2003. Performance test results on the spectrogram shift by gravity direction variation, slit illumination function, efficiency and the precision of the radial velocity measurements show the capabilities of the LSS are much improved in every respect comparing with those of the MDS.
In vitro Characterization Study of Bacillus mojavensis KJS-3 for a Potential Probiotic
김강민,정태성,옥선,고찬영,강재선 한국식품과학회 2011 Food Science and Biotechnology Vol.20 No.4
The identification and characterization of Bacillus mojavensis KJS-3 was performed by in vitro tests. A 16S rDNA sequence and phylogenetic tree demonstrated that this isolate belongs to the B. mojavensis group. B. mojavensis KJS-3 supplies nutrients by synthesizing several vitamins. B. mojavensis KJS-3 produces α-amylase and protease. B. mojavensis KJS-3 is cultured well under aerobic conditions without gas production. B. mojavensis KJS-3 allows for assimilation of cholesterol and bile salt hydrolase activity. Finally, adhesion experiments using Caco-2 cells revealed that the adherence of B. mojavensis KJS-3 to Caco-2 cells was approximately 51.2±8.14%.
김강민,한인우,유계화,Kim, Kang-Min,Han, In-Woo,Plachinda, S.,Valyavin, G.,Yoo, Kye-Hwa 한국천문학회 2005 天文學論叢 Vol.20 No.1
We plan to install the polarimetric optics in the AGU(acqusition and guiding unit) of the 1.8 m telescope at the BOAO(Bohyunsan Optical Astronomy Observatory). With this, the spectropolarimetric observations with the resolution of 45,000 and 60,000 in 4,000 to $8,000{\AA}$ ange could be done by the BOES(BOao Echelle Spectrograph). If we use the precision radial velocity measurement capability of the BOES, the accuracy of the magnetic field intensity measurements with this new BOES stokesmeter will be much increased. We present here the design concept of the BOES stokesmeter. Some details on the optics, mechanical parts, fiber parts and the lab test procedures of this stokesmeter are explained.