http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
마찰교반 점용접한 A 5052 알루미늄 합금판재의 접합부 특성
연윤모,이원배,이창용,정승부,송건,Yeon, Yun-Mo,Lee, Won-Bae,Lee, Chang-Yong,Jung, Seung-Boo,Song, Keun 대한용접접합학회 2006 대한용접·접합학회지 Vol.24 No.1
In this study, the microstructure and mechanical properties of spot friction stir welded A 5052 alloy were investigated. Especially, the effect of insertion depth of welding tool on microstructural changes and mechanical properties was investigated in order to obtain the optimum spot friction stir welding condition. The lap shear load of spot friction stir welded A 5052 alloy plates showed lower value at the shallowest insertion depth and increased with tool insertion depth. At 1.6mm, the maximum value of 3.35 kN was obtained, and then dropped to lower load when the insertion depth was deeper. Spot friction stir welded joints showed shear fracture mode at shallower insertion depths and fracture mode changed to plug fracture mode as the insertion depth was deeper.
연윤모,민형복,Yeon, Yun-Mo,Min, Hyeong-Bok 한국정보처리학회 1997 정보처리학회논문지 Vol.4 No.2
VSLI회로에서 스위치 레벨 결함 모델은 stuck-at결함만 사용하는데 한계가 있다. 따라서 본 연구는 스위치 레벨 결함 모델인 트랜지스터 stuck-open과 stuck-close결함을 다룰 수 있는결함 시뮬레이터를 구현한다. 스위치 레벨 회로는 이론적으로 신호 흐름이 양방향으로 전달되지만 실제로 대부분의 신호 흐름은 약 95%정도가 단 방향을로 설정되어 평가되는 것으로 나타내고 있다. 본 연구에서는 스위치 레벨 회로를 단반향 그래프 모델 로 변환시켜 해석한다. 스위치 레벨 회로는 EDIF컴파일러에 의해 입력되고 두개의 단방향으로 재구성된 자료구조를 만든다. 스위치 레벨 회로는 신호 흐름 경로가 도입되는 지배적 경로 기법이 제시된다. 지배적 경로는 경로를 판단하여 최종 출력 상태값을 결정하는 논리 시뮬레이션을 수행한다. 스위치 레벨 결함 시뮬레이션은 노들들로 연결되는 경로 상에 임의 트랜지스터의 stuck-open,stuck-close 결함을 주입시키고, 트랜지스터 저항값을 적용한 노드세기의 계산에 의한 지배적 경로를 평가한다. 이때 최초 입력은 two pattern vector를 인가하여 정상회로의 최종 출력 상태값과 결함회로의 출력 상태값을 비교하여 결함 검색하며, 그결함 검색의 정확성 을 보인다. This paper describes an implementation of fault simulator that can switch level fault models such as transistor stuck-open and stuck-closed faults as well as stuck-at faults. It overcomes the limitation when only stuck-at faults are used in VLSI circuits. Signal flow of a transistor switch is bidirectional in its nature, but most of signal flows in a switch level circuits, about 95%, are in one direction. This fault simulator focuses on the way which changes a switch level circuit into a graph model with two directed edges. Two paths from Vdd to ground and from ground to directions. Logic simulation is performed along dominant signal flows. The switch level fault simulation estimates the dominant path by injecting switch-level fualts, and pattern vectors are used for faults simulation. Experimental results are shown to demonstrate correctness of the fault simulator.
AISI 304 스텐레스강의 응력부식귀열에 미치는 냉간가공과 아닐링의 영향
연윤모,권숙인 대한금속재료학회(대한금속학회) 1983 대한금속·재료학회지 Vol.21 No.2
A study was made of the effects of cold working and annealing on the stress corrosion cracking of AlSl 304 stainless steel in boding 42% MgCl₂solution. When the 60% or 76% of yield stress was applied, the resistance to SCC showed maximum at 30% of cold work. However, when the same load was applied to the annealed specimens after cold working, the resistance to SCC decreased abruptly at 675℃ annealing. The fracture mode changed mixed →intergranular →transgranular as the amount of cold work increased.