http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
The Effect of CdS QDs Structure on the InGaP/GaAs/Ge Triple Junction Solar Cell Efficiency
Chen-Chen Chung,Binh Tinh Tran,Hau-Vei Han,Yen-Teng Ho,Hung-Wei Yu,Kung-Liang Lin,Hong-Quan Nguyen,Peichen Yu,Hao-Chung Kuo,Edward Yi Chang 대한금속·재료학회 2014 ELECTRONIC MATERIALS LETTERS Vol.10 No.2
This work describes optical and electrical characteristics of InGaP/GaAs/Ge triple-junction (T-J) solar cells with CdS quantum dots (QDs) fabricated by a novel chemical solution. With the anti-reflective feature at long wavelength and down-conversion at UV regime, the CdS quantum dot effectively enhance the overall power conversion efficiency more than that of a traditional GaAs-based device. Experimental results indicate that CdS quantum dot can enhance the short-circuit current by 0.33 mA/cm2, which is observed for the triple-junction solar cells with CdS QDs of about 3.5 nm in diameter. Moreover, the solar cell conversion efficiency is improved from 28.3% to 29.0% under one-sun AM 1.5 global illumination I-V measurement.
Yen-Yang Chen,Chen-Chi Wang,Ying-Cheng Lin,John Y Kao,Chun-Yi Chuang,Yung-An Tsou,Ja-Chih Fu,Sheng-Shun Yang,Chi-Sen Chang,Han-Chung Lien 대한소화기 기능성질환∙운동학회 2023 Journal of Neurogastroenterology and Motility (JNM Vol.29 No.1
Background/AimsHypopharyngeal multichannel intraluminal impedance-pH (HMII-pH) technology incorporating 2 trans-upper esophageal sphincter impedance channels has been developed to detect pharyngeal reflux. We used the HMII-pH technique to validate the candidate pharyngeal acid reflux (PAR) episodes based on the dual-pH tracings and determined the interobserver reproducibility. MethodsWe conducted a cross-sectional study in tertiary centers in Taiwan. Ninety patients with suspected laryngopharyngeal reflux and 28 healthy volunteers underwent HMII-pH test when off acid suppressants. Candidate PAR episodes were characterized by pharyngeal pH drops of at least 2 units and reaching a nadir pH of 5 within 30 seconds during esophageal acidification. Two experts manually independently identified candidate PAR episodes based on the dual-pH tracings. By reviewing the HMII-pH tracings, HMII-pH-proven PAR episodes were subsequently confirmed. The consensus reviews of HMII-pH-proven PAR episodes were considered to be the reference standard diagnosis. The interobserver reproducibility was assessed. ResultsA total of 105 candidate PAR episodes were identified. Among them 84 (80.0%; 95% CI, 71.0-87.0%) were HMII-pH-proven PAR episodes (82 in 16 patients and 2 in 1 healthy subject). Patients tended to have more HMII-pH-proven PAR episodes than healthy controls (median and percentile values [25th, 75th, and 95th percentiles]: 0 [0, 0, 3] vs 0 [0, 0, 0], P = 0.067). The concordance rate in diagnosing HMII-pH-proven PAR episodes between 2 independent observers was 92.2%. ConclusionOur preliminary data showed that 80.0% (71.0-87.0%) of the proposed candidate PAR episodes were HMII-pH-proven PAR episodes, among which the interobserver reproducibility was good.
Effect of the Circle-Grid Electrodes on Concentrated GaAs Solar Cell Efficiency
Chen-Chen Chung,Binh Tinh Tran,Ming-Hung Han,Kung-Liang Lin,Hung-Wei Yu,Yen-Teng Ho,Chun-Yen Chang,Edward Yi Chang 대한금속·재료학회 2014 ELECTRONIC MATERIALS LETTERS Vol.10 No.5
In this study, we investigate the effect of the shading factor of the front grid pattern on concentrated solar cell efficiency, taking the trade-off between the series resistance of the electrodes and the amount of incident light into consideration. We examine the thermal effect with regard to five different circle-grid electrode patterns of the front contact. The front contacts with different grid patterns affect the characteristics of light-concentratedtype GaAs single-junction solar cells. The device parameters analyzed include the open-circuit voltage (Voc), short-circuit current (Isc), fill factor (FF) and conversion efficiency (η). The results of our study show that for a concentration ratio greater than 60x with AM1.5G, the device with a shading factor of 7.1% has the best cell efficiency of 27.05%, due to the smaller current crowding at the center spot. The results indicate that the conversion efficiency of solar cells can be improved by establishing a compromise between the shading effect and the series resistance effect.
( Chen Wang Chang ),( Shu Chen Wei ),( Jen Wei Chou ),( Tzu Chi Hsu ),( Chiao Hsiung Chuang ),( Ching Pin Lin ),( Wen Hung Hsu ),( Hsu Heng Yen ),( Jen Kou Lin ),( Yi Jen Fang ),( Horng Yuan Wang ),( 대한장연구학회 2014 Intestinal Research Vol.12 No.4
Background/Aims: Only moderate to severe Crohn`s Disease (CD) patients without a satisfactory conventional therapy effect are eligible to get reimbursement from the National Health Insurance of Taiwan for using adalimumab. These are more stringent criteria than in many Western countries and Japan and Korea. We aim to explore the efficacy of using adalimumab in CD patients under such stringent criteria. Methods: A retrospective analysis was conducted in nine medical centers in Taiwan and we collected the results of CD patients receiving adalimumab from Sep 2009 to Mar 2014. The clinical characteristics, response measured by CDAI (Crohn`s Disease Activity Index), adverse events and survival status were recorded and analyzed. CR-70, CR-100, and CR-150 were defined as attaining a CDAI decrease of 70, 100 or 150 points compared with baseline. Results: A total of 103 CD patient records were used in this study. Sixty percent of these patients received combination therapy of adalimumab together with immunomodulators. CR-70 was 68.7%, 74.5% and 88.4% after week 4, 8 and 12 of treatment, respectively. The steroid-free rate, complications and survival were 47.6%, 9.7% and 99% of patients, respectively. In considering the mucosal healing, only 25% patients achieve mucosal healing after treatment for 6 to12 months. Surgery was still needed in 16.5% of patients. Combination treatment of adalimumab with immunomodulators further decreased the level of CDAI at week 8 when compared with the monotherapy. Conclusions: Even under the stringent criteria for using adalimumab, the response rate was comparable to those without stringent criteria. (Intest Res 2014;12:287-292)
( Wei-chen Lin ),( Jen-wei Chou ),( Hsu-heng Yen ),( Wen-hung Hsu ),( Hung-hsin Lin ),( Jen-kou Lin ),( Chiao-hsiung Chuang ),( Tien-yu Huang ),( Horng-yuan Wang ),( Shu-chen Wei ),( Jau-min Wong ) 대한장연구학회 2017 Intestinal Research Vol.15 No.4
Background/Aims: In Taiwan, due to budget limitations, the National Health Insurance only allows for a limited period of biologics use in treating moderate to severe Crohn’s disease (CD). We aimed to access the outcomes of CD patients following a limited period use of biologics, specifically focusing on the relapse rate and remission duration; also the response rate to second use when applicable. Methods: This was a multicenter, retrospective, observational study and we enrolled CD patients who had been treated with adalimumab (ADA) according to the insurance guidelines from 2009 to 2015. Results: A total of 54 CD patients, with follow-up of more than 6 months after the withdrawal of ADA, were enrolled. The average period of treatment with ADA was 16.7±9.7 months. After discontinuing ADA, 59.3% patients suffered a clinical relapse. In the univariate analysis, the reason for withdrawal was a risk factor for relapse (P=0.042). In the multivariate analysis, current smoker became an important risk factor for relapse (OR, 3.9; 95% CI, 1.2-14.8; P=0.044) and male sex was another risk factor (OR, 2.9; 95% CI, 1.1-8.6; P=0.049). For those 48 patients who received a second round of biologics, the clinical response was seen in 60.4%, and 1 anaphylaxis occurred. Conclusions: Fifty-nine percent of patients experienced a relapse after discontinuing the limited period of ADA treatment, and most of them occurred within 1 year following cessation. Male sex and current smoker were risk factors for relapse. Though 60.4% of the relapse patients responded to ADA again. (Intest Res 2017;15:487-494)
Portable Laser Doppler Flowmeter for Microcirculation Detection
Chang-Lin Hu,Meng-Lin Li,Zhan-Sheng Lin,Yen-Yu Chen,Yuan-Hsiang Lin 대한의용생체공학회 2013 Biomedical Engineering Letters (BMEL) Vol.3 No.2
Purpose The microcirculatory system of the human body is closely related to its physiological conditions. The laser Doppler flowmeter can detect symptoms through variations in the microcirculation; however, the present commercial Doppler flowmeter is very expensive, heavy, and inconvenient to carry. Therefore, an inexpensive, small, and portable laser Doppler flowmeter is proposed. Methods In this study, we designed a laser Doppler flowmeter transmitting receiving module based on the fundamental principles of laser Doppler, using a common computer for flow calculation. A self-designed correction system was used to validate the portable laser Doppler flowmeter. Results The coefficient of correlation between the mean frequency offset <ω> of the flowmeter and the actual mimicked blood flow rate reached a high value of R = 0.99, and the variations in microcirculation flow could be accurately measured. Conclusions The results proved that the low-cost portable laser Doppler flowmeter can be used extensively in early symptom detection for disease prevention and control.
Enhanced Phase Relaxation in a Hybrid Ferromagnet/Semiconductor System
Kuang Yao Chen,Chun-Kai Yang,N. Aoki,Y. Ochiai,Y. Ujiie,K. A. Cheng,Li-Hung Lin,C. F. Huang,Yu-Ru Li,Yen Shung Tseng,Po-Tsun Lin,Jau-Yang Wu,Sheng-Di Lin,C.-T. Liang 한국물리학회 2009 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.55 No.1
Hybrid ferromagnet/semiconductor systems have been the focus of considerable attention because of the transport properties of two-dimensional electron systems and their potential applications to magnetic storage and sensing devices. We use the weak localization effect to probe the dephasing mechanism at low temperatures. In our study, the zero-temperature phase-relaxation rate can be enhanced in a hybrid ferromagnet/semiconductor system, which may be due to the inhomogeneous magnetic field emanating from the Ni film. The result may improve understanding of the issue of zero-temperature dephasing in disordered systems. Hybrid ferromagnet/semiconductor systems have been the focus of considerable attention because of the transport properties of two-dimensional electron systems and their potential applications to magnetic storage and sensing devices. We use the weak localization effect to probe the dephasing mechanism at low temperatures. In our study, the zero-temperature phase-relaxation rate can be enhanced in a hybrid ferromagnet/semiconductor system, which may be due to the inhomogeneous magnetic field emanating from the Ni film. The result may improve understanding of the issue of zero-temperature dephasing in disordered systems.