화재손상을 입은 철근콘크리트 보에서 외적 포스트텐셔닝 강봉의 전단 보강
이수헌 대한건축학회 2023 대한건축학회논문집 Vol.39 No.1
The purpose of this study is to discuss the applicability, strengthening effect and improvements when an externally post-tensioned steel rodsystem is applied to a fire-damaged reinforced concrete (RC) beam. A total of twelve specimens were prepared in three groups and tested tofail. Group one was not heated, and group two and group three were heated to 700℃ and 1,000℃, respectively. In each group, one beamwithout externally post-tensioned steel rods was designated as a control beam and three beams had the externally post-tensioned steel rods of18 mm, 22 mm or 28 mm in diameter. The initial effective tension of about 2,000 was applied to the steel rods. Test results indicated thatthis can be applied to fire-damaged RC because externally post-tensioning increased the load-carrying capacity by more than 67%. However,additional reinforcement is required in the part where the deviator and anchorage are installed since the concrete surface is weakened bymoisture evaporation at high temperatures. 이 연구는 화재손상을 입은 철근콘크리트 보에 외적 포스트텐셔닝 강봉을 적용하였을 때 적용 가능성과 보강 효과, 개선점 등을 논한다. 총 12개의 실험체가 3개의 실험군으로 구성되었고 파괴 시까지 실험하였다. 실험군 #1은 고온에 노출하지 않았고, 실험군 #2와 #3은 각각 700℃, 1,000℃에 노출하였다. 각 실험군은 포스트텐셔닝 강봉으로 보강하지 않은 기본 실험체 1개, 18mm, 22mm, 28mm 강봉으로 보강한 3개의 실험체로 디자인되었다. 강봉에는 초기 긴장력 약 2000με이 도입되었다. 실험결과를 보면, 포스트텐셔닝 강봉 보강법은 67% 이상의 강도 보강 효과를 보였기 때문에 그 보강 효과를 입증하였다. 하지만 고온에 콘크리트 표면의 손상이 발생하였기에 데비에이터와 정착구 부근에는 추가 보강이 이루어져야 할 것으로 판단한다.