RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • Treatment of fever with traditional Chinese medicine according to Zheng on cancer patients (based on case reports)

        Peng Cao,Lan-Ying Liu,Xue-Ting Cai,Xiao-Ning Wang,Jie-Ge Huo,Zhong-Ying Zhou 셀메드 세포교정의약학회 2012 셀메드 (CellMed) Vol.2 No.2

        Fever in cancer patients is often due to the following causes: evil qi and toxity stagnancy, disorders of qi and blood, deficiencies of zang and fu organs, and the disorder of yin and yang. The treatments given to cancer patients with a fever are according to five: (a) Excessive inner heat and toxicants: remove heat and the toxicant, induce purgation. We use Cheng-Qi-Tang plus Qing-Wen-Bai-Du-Yin. (b) Tangle of damp and heat, and qi stagnancy: remove damp and heat, smooth the qi channel. We use Gan-Lu-Xiao-Du-Dan or San-Ren-Tang. (c) Obvious blood and heat stagnancy: remove heat and blood stasis. We use Xue-Fu-Zhu-Yu-Tang. (d) Deficiency of spleen qi, inner heat caused by a yin deficiency: nourish spleen qi and yin to remove the inner heat. We use Bu-Zhong-Yi-Qi-Tang or Xiao-Jian-Zhong-Tang. (e) Prominent yin deficiency and hectic fever: replenish yin and remove inner heat. We use Qing-Hao-Bie-Jia-Tang or Chai-Qian-Mei-Lian-San. The pathogenesis of fever in cancer patients is complicated. We can see both deficiency and excess in one differentiation. Therefore, we must make sure of it, then we can get the most effective treatment.

      • One-Step Oxidation of Benzene Producing Eight High Value Compounds Using Nitric Acid and Hydrogen Peroxide

        Zhen-xue Liu,Zhong-xue Gan,Jun-jie Gu,Qing-feng Song 대전대학교 환경문제연구소 2015 환경문제연구소 논문집 Vol.19 No.-

        Benzene was oxidized by binary oxidants composed of nitric acid and hydrogen peroxide at 80℃. The product obtained was analyzed with gas chromatograph-mass spectrometer. Eight high value compounds, 2-nitrophenol, 2-chloro-6-nitrophenol, 4-chloro-2- nitrophenol, 2-chloro-4-nitrophenol, 2,4-dinitrophenol, 4-nitrophenol, 2,6-dinitrophenol and 2-chloro-4,6-dinitro-phenol were found, which they have high contents in the range from 4.28% to 32.52%. These compounds are very widely used in organic synthesis. e.g., synthesizing dye, medicines and chemical reagents, pesticide, explosive, polymer, etc.

      • SCIESCOPUSKCI등재

        Kinetics of a Cloned Special Ginsenosidase Hydrolyzing 3-O-Glucoside of Multi-Protopanaxadiol-Type Ginsenosides, Named Ginsenosidase Type 3

        ( Xue Feng Jin ),( Hong Shan Yu ),( Dong Ming Wang ),( Ting Qiang Liu ),( Chun Ying Liu ),( Dong Shan An ),( Wan Taek Im ),( Song Gun Kim ),( Feng Xie Jin ) 한국미생물 · 생명공학회 2012 Journal of microbiology and biotechnology Vol.22 No.3

        In this paper, the kinetics of a cloned special glucosidase, named ginsenosidase type III hydrolyzing 3-O-glucoside of multi-protopanaxadiol (PPD)-type ginsenosides, were investigated. The gene (bgpA) encoding this enzyme was cloned from a Terrabacter ginsenosidimutans strain and then expressed in E. coli cells. Ginsenosidase type III was able to hydrolyze 3-O-glucoside of multi-PPD-type ginsenosides. For instance, it was able to hydrolyze the 3- O-β-D-(1→2)-glucopyranosyl of Rb1 to gypenoside XVII, and then to further hydrolyze the 3-O-β-D-glucopyranosyl of gypenoside XVII to gypenoside LXXV. Similarly, the enzyme could hydrolyze the glucopyranosyls linked to the 3-O- position of Rb2, Rc, Rd, Rb3, and Rg3. With a larger enzyme reaction Km value, there was a slower enzyme reaction speed; and the larger the enzyme reaction Vmax value, the faster the enzyme reaction speed was. The Km values from small to large were 3.85 mM for Rc, 4.08 mM for Rb1, 8.85 mM for Rb3, 9.09 mM for Rb2, 9.70 mM for Rg3(S), 11.4 mM for Rd and 12.9 mM for F2; and Vmax value from large to small was 23.2 mM/h for Rc, 16.6 mM/h for Rb1, 14.6 mM/h for Rb3, 14.3 mM/h for Rb2, 1.81mM/h for Rg3(S), 1.40 mM/h for Rd, and 0.41 mM/h for F2. According to the Vmax and Km values of the ginsenosidase type III, the hydrolysis speed of these substrates by the enzyme was Rc>Rb1>Rb3>Rb2>Rg3(S)>Rd>F2 in order.

      • KCI등재

        Characterization and expression of calcium-activated potassium channels (Slo) in ovary of the mud crab, Scylla paramamosain

        Xue-Liang Liu,Hai-Hui Ye,Hui-Yang Huang,Jie Gong,Ya-Nan Yang 한국유전학회 2014 Genes & Genomics Vol.36 No.1

        Large conductance calcium-activated potassiumchannels (Slo) play important roles in controllingneuronal excitability. At present, very little is known aboutthe function of Slo channels on ovarian development. Wecloned the SPSlo gene from the mud crab, Scylla paramamosain. This gene shows 91 and 93 % sequence identityto PISlo from the spiny lobster, Panulirus interruptus andCBSlo from the jonah crab, Cancer borealis, respectively. We isolated six variants of the SPSlo cDNA within S. paramamosain ovary tissue. Sequence analysis indicatedthat there were at least seven alternative sites in SPSlo,each with multiple alternative segments. Real-time PCRshowed that the SPSlo gene was expressed in various tissues,and highly expressed in brain and ovary. In addition,the expression of SPSlo changed throughout ovariandevelopment, highest at the early-developing stage (StageII) followed by a slow decrease in subsequent stages. Theseresults suggested that SPSlo channels may be implicated inthe ovarian development of the mud crab.

      • Correlation Study of Knowledge and Behavior Regarding Breast Care among Female Undergraduate Students in China

        Liu, Meng-Xue,Li, Jian,Geng, Yun-Long,Wang, Yan-Chun,Li, Jie,Chen, Yu-Juan,Ali, Gholam,Tarver, Siobhan L.,Wen, Yu-Feng,Sun, Wen-Jie Asian Pacific Journal of Cancer Prevention 2014 Asian Pacific journal of cancer prevention Vol.15 No.24

        Background: This study aimed to understand the relationship between knowledge level and behavior on breast care in Chinese students, so as to provide strategies for improving the health education of breast care and subsequently for aiding in breast cancer prevention. Materials and Methods: A self-designed questionnaire was used to evaluate breast care knowledge level and characterize related behavior. Correlation analysis was conducted for the knowledge level and behavior. The study was carried out using 597 female undergraduate students in medical and non-medical colleges in Wuhu, China. Results: The average score of breast care knowledge was $5.32{\pm}1.68$ ($5.62{\pm}1.68$ and $5.00{\pm}1.68$ for medical and non-medical students, respectively), with a greater score value for sophomores ($5.59{\pm}1.72$) than freshmen ($5.18{\pm}1.65$). The average score of breast care behavior was $2.21{\pm}1.13$, again with a greater value in sophomores ($2.37{\pm}1.15$) than freshmen ($2.21{\pm}1.13$). A significant positive correlation (r=0.231, p<0.01) between knowledge scores and behavior scores was observed. In addition, various factors, including paying attention to breast care information, receiving breast self-examination guidance, TV program and Internet, were found to influence breast care knowledge. Conclusions: In general, female undergraduate students lack of self-awareness of breast care with a low rate of breast self-examination. It is necessary to carry out health education to improve early detection of breast cancer.

      • SCISCIESCOPUSKCI등재

        Supervised-learning-based algorithm for color image compression

        Liu, Xue-Dong,Wang, Meng-Yue,Sa, Ji-Ming Electronics and Telecommunications Research Instit 2020 ETRI Journal Vol.42 No.2

        A correlation exists between luminance samples and chrominance samples of a color image. It is beneficial to exploit such interchannel redundancy for color image compression. We propose an algorithm that predicts chrominance components Cb and Cr from the luminance component Y. The prediction model is trained by supervised learning with Laplacian-regularized least squares to minimize the total prediction error. Kernel principal component analysis mapping, which reduces computational complexity, is implemented on the same point set at both the encoder and decoder to ensure that predictions are identical at both the ends without signaling extra location information. In addition, chrominance subsampling and entropy coding for model parameters are adopted to further reduce the bit rate. Finally, luminance information and model parameters are stored for image reconstruction. Experimental results show the performance superiority of the proposed algorithm over its predecessor and JPEG, and even over JPEG-XR. The compensation version with the chrominance difference of the proposed algorithm performs close to and even better than JPEG2000 in some cases.

      • KCI등재

        MnO2/graphene supported on Ni foam: an advanced electrode for electrochemical detection of Pb(II)

        Liu Rui,Zhang Chao-Jun,Han Xue,Wu Tian-Heng,Liu Ri-Jia,Sun Yuan,Jin Shuang 한국탄소학회 2023 Carbon Letters Vol.33 No.3

        Graphene-derived materials are an excellent electrode for electrochemical detection of heavy metals. In this study, a MnO2/graphene supported on Ni foam electrode was prepared via ultrasonic impregnation and electrochemical deposition. The resulting electrode was used to detect Pb(II) in the aquatic environment. The graphene and MnO2 deposited on the Ni foam not only improved active surface area, but also promoted the electron transfer. The electrochemical performance towards Pb(II) was evaluated by cyclic voltammetry (CV) and square wave anodic stripping voltammetry (SWASV). The prepared electrode exhibited lower limit of detection (LOD, 0.2 μM (S/N = 3)) and good sensitivity (59.9 μAμM−1) for Pb(II) detection. Moreover, the prepared electrodes showed good stability and reproducibility. This excellent performance can be attributed to the strong adhesion force between graphene and MnO2, which provides compact structures for the enhancement of the mechanical stability. Thus, these combined results provide some technical considerations and scientific insights for the detection of heavy metal ions using composite electrodes.

      • Analysis of Mammographic Breast Density in a Group of Screening Chinese Women and Breast Cancer Patients

        Liu, Jing,Liu, Pei-Fang,Li, Jun-Nan,Qing, Chun,Ji, Yu,Hao, Xi-Shan,Zhang, Xue-Ning Asian Pacific Journal of Cancer Prevention 2014 Asian Pacific journal of cancer prevention Vol.15 No.15

        Background: A dense breast not only reduces the sensitivity of mammography but also is a moderate independent risk factor for breast cancer. The percentage of Western women with fat breast tissue is higher aged 40 years or older. To a certain extent, mammography as a first choice of screening imaging method for Western women of this group is reasonable. Hitherto, the frequency and age distribution of mammographic breast density patterns among Chinese women had not been characterized. The purpose of this study was to investigate the frequency and age distribution of mammographic breast density patterns among a group of Chinese screening women and breast cancer patients in order to provide useful information for age-specific guidelines for breast cancer screening in Chinese women. Methods: A retrospective review of a total of 3,394 screening women between August and December 2009 and 2,527 breast cancer patients between July 2011 and June 2012 was conducted. Descriptive analyses were used to examine the association between age and breast density. The significance of differences of breast density between the screening women and the breast cancer patients was examined using nonparametric tests. Results: There was a significant inverse relationship between age and breast density overall (r=-0.37, p< 0.01). Breast density of the breast cancer patients in the subgroups of 40-49 years old was greater compared with that of the screening women, the same in those aged 50-54 years and in those 55 years old or older, less than in the screening group. Conclusions: With regard to the Chinese women younger than 55 years old, the diagnostic efficiency of breast cancer screening imaging examinations may be potentially improved by combining screening mammography with ultrasound.

      • Elastography for Breast Cancer Diagnosis: a Useful Tool for Small and BI-RADS 4 Lesions

        Liu, Xue-Jing,Zhu, Ying,Liu, Pei-Fang,Xu, Yi-Lin Asian Pacific Journal of Cancer Prevention 2014 Asian Pacific journal of cancer prevention Vol.15 No.24

        The present study aimed at evaluating and comparing the diagnostic performance of B-mode ultrasound (US), elastography score (ES), and strain ratio (SR) for the differentiation of breast lesions. This retrospective study enrolled 431 lesions from 417 in-hospital patients. All patients were examined with both conventional ultrasound and elastography. Two experienced radiologists reviewed ultrasound and elasticity images. The histopathologic result obtained from ultrasound-guided core biopsy or operation excisions were used as the reference standard. Pathologic examination revealed 276 malignant lesions (64%) and 155 benign lesions (36%). A cut-off point of 4.15 (area under the curve, 0.891) allowed significant differentiation of malignant and benign lesions. ROC (receiver-operating characteristic) curves showed a higher value for combination of B-mode ultrasound and elastography for the diagnosis of breast lesions. Conventional ultrasound combined elastography showed high sensitivity, specificity, and accuracy for group II lesions (10mm<lesion diameter ${\leq}20mm$). Elastography combined with conventional ultrasound show high specificity and accuracy for differentiation of benign and malignant breast lesions. Elastography is particularly important for the diagnosis of BI-RADS 4 and small breast lesions.

      • SCOPUSKCI등재

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼