RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Improving Diagnostic Performance of MRI for Temporal Lobe Epilepsy With Deep Learning-Based Image Reconstruction in Patients With Suspected Focal Epilepsy

        Suh Pae Sun,Park Ji Eun,Roh Yun Hwa,Kim Seonok,Jung Mina,Koo Yong Seo,Lee Sang-Ahm,Choi Yangsean,Kim Ho Sung 대한영상의학회 2024 Korean Journal of Radiology Vol.25 No.4

        Objective: To evaluate the diagnostic performance and image quality of 1.5-mm slice thickness MRI with deep learningbased image reconstruction (1.5-mm MRI + DLR) compared to routine 3-mm slice thickness MRI (routine MRI) and 1.5-mm slice thickness MRI without DLR (1.5-mm MRI without DLR) for evaluating temporal lobe epilepsy (TLE). Materials and Methods: This retrospective study included 117 MR image sets comprising 1.5-mm MRI + DLR, 1.5-mm MRI without DLR, and routine MRI from 117 consecutive patients (mean age, 41 years; 61 female; 34 patients with TLE and 83 without TLE). Two neuroradiologists evaluated the presence of hippocampal or temporal lobe lesions, volume loss, signal abnormalities, loss of internal structure of the hippocampus, and lesion conspicuity in the temporal lobe. Reference standards for TLE were independently constructed by neurologists using clinical and radiological findings. Subjective image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were analyzed. Performance in diagnosing TLE, lesion findings, and image quality were compared among the three protocols. Results: The pooled sensitivity of 1.5-mm MRI + DLR (91.2%) for diagnosing TLE was higher than that of routine MRI (72.1%, P < 0.001). In the subgroup analysis, 1.5-mm MRI + DLR showed higher sensitivity for hippocampal lesions than routine MRI (92.7% vs. 75.0%, P = 0.001), with improved depiction of hippocampal T2 high signal intensity change (P = 0.016) and loss of internal structure (P < 0.001). However, the pooled specificity of 1.5-mm MRI + DLR (76.5%) was lower than that of routine MRI (89.2%, P = 0.004). Compared with 1.5-mm MRI without DLR, 1.5-mm MRI + DLR resulted in significantly improved pooled accuracy (91.2% vs. 73.1%, P = 0.010), image quality, SNR, and CNR (all, P < 0.001). Conclusion: The use of 1.5-mm MRI + DLR enhanced the performance of MRI in diagnosing TLE, particularly in hippocampal evaluation, because of improved depiction of hippocampal abnormalities and enhanced image quality.

      • KCI등재

        Effects of Smoking on Menopausal Age: Results From the Korea National Health and Nutrition Examination Survey, 2007 to 2012

        Hee Jung Yang,Pae Sun Suh,김수정,이순영 대한예방의학회 2015 Journal of Preventive Medicine and Public Health Vol.48 No.4

        Objectives: Decreased fertility and impaired health owing to early menopause are significant health issues. Smoking is a modifiable health-related behavior that influences menopausal age. We investigated the effects of smoking-associated characteristics on menopausal age in Korean women. Methods: This study used data from the Korea National Health and Nutrition Examination Survey from 2007 to 2012. Menopausal age in relation to smoking was analyzed as a Kaplan-Meier survival curve for 11 510 women (aged 30 to 65 years). The risk of entering menopause and experiencing early menopause (before age 48) related to smoking were assessed using a Cox proportional hazards model. Results: The menopausal age among smokers was 0.75 years lower than that among non-smokers (p<0.001). The results of the Cox proportional hazards model showed pre-correction and post-correction risk ratios for entering menopause related to smoking of 1.26 (95% confidence interval [CI], 1.09 to 1.46) and 1.27 (95% CI, 1.10 to 1.47), respectively, and pre-correction and post-correction risk ratios for experiencing early menopause related to smoking of 1.36 (95% CI, 1.03 to 1.80) and 1.40 (95% CI, 1.05 to 1.85), respectively. Conclusions: Smokers reached menopause earlier than non-smokers, and their risk for experiencing early menopause was higher.

      • SCOPUSKCI등재

        Effects of Smoking on Menopausal Age: Results From the Korea National Health and Nutrition Examination Survey, 2007 to 2012

        Yang, Hee Jung,Suh, Pae Sun,Kim, Soo Jeong,Lee, Soon Young The Korean Society for Preventive Medicine 2015 Journal of Preventive Medicine and Public Health Vol.48 No.4

        Objectives: Decreased fertility and impaired health owing to early menopause are significant health issues. Smoking is a modifiable health-related behavior that influences menopausal age. We investigated the effects of smoking-associated characteristics on menopausal age in Korean women. Methods: This study used data from the Korea National Health and Nutrition Examination Survey from 2007 to 2012. Menopausal age in relation to smoking was analyzed as a Kaplan-Meier survival curve for 11 510 women (aged 30 to 65 years). The risk of entering menopause and experiencing early menopause (before age 48) related to smoking were assessed using a Cox proportional hazards model. Results: The menopausal age among smokers was 0.75 years lower than that among non-smokers (p<0.001). The results of the Cox proportional hazards model showed pre-correction and post-correction risk ratios for entering menopause related to smoking of 1.26 (95% confidence interval [CI], 1.09 to 1.46) and 1.27 (95% CI, 1.10 to 1.47), respectively, and pre-correction and post-correction risk ratios for experiencing early menopause related to smoking of 1.36 (95% CI, 1.03 to 1.80) and 1.40 (95% CI, 1.05 to 1.85), respectively. Conclusions: Smokers reached menopause earlier than non-smokers, and their risk for experiencing early menopause was higher.

      • KCI등재

        Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study

        Ryu Jae-Chan,Yoon Jong-Tae,Kim Byung Jun,Kim Mi Hyeon,Moon Eun Ji,Suh Pae Sun,Roh Yun Hwa,Moon Hye Hyeon,Kwon Boseong,Lee Deok Hee,Song Yunsun 대한영상의학회 2023 Korean Journal of Radiology Vol.24 No.7

        Objective: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. Materials and Methods: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients’ 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. Results: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm2, P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. Conclusion: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head offcentering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼