RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        The effects of gas mixtures on hydrogen permeation through Pd-Ag/V-Ni alloy composite membrane

        Hulme, J.,Komaki, M.,Nishimura, C.,Gwak, J. Elsevier 2011 Current Applied Physics Vol.11 No.4

        The effects of gas mixtures on hydrogen permeation through Pd-Ag coated V-Ni composite membranes were investigated by gas permeation technique in the temperature range of 473-673 K at atmospheric pressure. Dense Pd-25Ag layer was sputtered on the V-15Ni alloy film prepared by arc-melting. Hydrogen permeation experiments for as-prepared Pd-Ag/V-Ni composite membrane were carried out with pure hydrogen and different gas mixtures of H<SUB>2</SUB>/CO<SUB>2</SUB> and H<SUB>2</SUB>/H<SUB>2</SUB>S. Long-term permeation tests were performed with the mixture feed of 30%-CO<SUB>2</SUB> in H<SUB>2</SUB> and 11 ppm-H<SUB>2</SUB>S in H<SUB>2</SUB>. As the percentage of gas impurity increased, the hydrogen permeability decreased. However, the composite membrane did not suffer irreparable damage when exposed to CO<SUB>2</SUB> and the flux value for pure hydrogen was readily recovered by post-treatment in the permeation system. For the H<SUB>2</SUB>S impurity, the interaction with the membrane surface was significantly different compared to CO<SUB>2</SUB>. Membrane permeability rapidly deteriorated when exposed to a small percentage of H<SUB>2</SUB>S. Nevertheless, the membrane does not seem to be damaged as the permeability was fully recovered by longer post-treatment with pure hydrogen.

      • SCOPUSKCI등재

        Detecting Activated Thrombin Activatable Fibrinolysis Inhibitor (TAFIa) and Inactivated TAFIa (TAFIai) in Normal and Hemophilia A Plasmas

        Hulme, John P.,An, Seong Soo A. Korean Chemical Society 2009 Bulletin of the Korean Chemical Society Vol.30 No.1

        Thrombin activatable fibrinolysis inhibitor (TAFI) also known as plasma procarboxypeptidase B or U is a 60 kD glycoprotein, which is the major modulator of fibrinolysis in plasma. TAFI is a proenzyme, which is activated by proteolytic cleavage to an active carboxypeptidase B-like enzyme (TAFIa, 35.8 kD) by thrombin/thrombomodulin and plasmin. Modulation of fibrinolysis occurs when TAFIa enzymatically removes C-terminal lysine residues of partially degraded fibrin, thereby inhibiting the stimulation of tissue plasminogen activator (t-PA) modulated plasminogen activation. TAFIa undergoes a rapid conformational change at $37{^{\circ}C}$ to an inactive isoform called TAFIai. Potato tuber carboxypetidase inhibitor (PTCI) was shown to specifically bind to TAFIa as well as TAFIai. In this study, a novel immunoassay TAFIa/ai ELISA was used for quantitation of the two TAFI activation isoforms TAFIa and TAFIai. The ELISA utilizes PTCI as the capture agent and a double antibody sandwich technique for the detection. Low levels of TAFIa/ai antigen levels were detected in normal plasma and elevated levels were found in hemophilia A plasmas. TAFIa/ai antigen represents a novel marker to monitor fibrinolysis and TAFIa/ai ELISA may be a valuable assay for studying the role of TAFI in normal hemostasis and in pathological conditions.

      • KCI등재

        The effects of gas mixtures on hydrogen permeation through Pd–Ag/V–Ni alloy composite membrane

        John Hulme,Masao Komaki,Chikashi Nishimura,곽지혜 한국물리학회 2011 Current Applied Physics Vol.11 No.4

        The effects of gas mixtures on hydrogen permeation through Pd―Ag coated V―Ni composite membranes were investigated by gas permeation technique in the temperature range of 473―673 K at atmospheric pressure. Dense Pd―25Ag layer was sputtered on the V―15Ni alloy film prepared by arc-melting. Hydrogen permeation experiments for as-prepared Pd―Ag/V―Ni composite membrane were carried out with pure hydrogen and different gas mixtures of H_2/CO_2 and H_2/H_2S. Long-term permeation tests were performed with the mixture feed of 30%-CO_2 in H_2 and 11 ppm-H_2S in H_2. As the percentage of gas impurity increased, the hydrogen permeability decreased. However, the composite membrane did not suffer irreparable damage when exposed to CO_2 and the flux value for pure hydrogen was readily recovered by post-treatment in the permeation system. For the H_2S impurity, the interaction with the membrane surface was significantly different compared to CO_2. Membrane permeability rapidly deteriorated when exposed to a small percentage of H_2S. Nevertheless, the membrane does not seem to be damaged as the permeability was fully recovered by longer post-treatment with pure hydrogen.

      • KCI등재

        Fabrication of a flexible multi-referenced surface plasmon sensor using room temperature nanoimprint lithography

        John P. Hulme,Seong Soo A. An,Nicholas Goddard,Yuji Miyahara,Akio Oki 한국물리학회 2009 Current Applied Physics Vol.9 No.2

        A novel surface plasmon sensing platform has been fabricated in a flexible format. The procedure used to fabricate a grating coupler for SPR excitation combined standard replica molding techniques with room temperature nanoimprint lithography producing a smooth repeating structure 600 nm in width and 10 nm high. In initial tests the platform demonstrated an average signal-to-noise ratio in excess of 100:1 and sensitivity to changes in the bulk refractive index of water with temperature. A novel surface plasmon sensing platform has been fabricated in a flexible format. The procedure used to fabricate a grating coupler for SPR excitation combined standard replica molding techniques with room temperature nanoimprint lithography producing a smooth repeating structure 600 nm in width and 10 nm high. In initial tests the platform demonstrated an average signal-to-noise ratio in excess of 100:1 and sensitivity to changes in the bulk refractive index of water with temperature.

      • KCI등재

        Detecting Activated Thrombin Activatable Fibrinolysis Inhibitor (TAFIa) and Inactivated TAFIa (TAFIai) in Normal and Hemophilia A Plasmas

        John P. Hulme,Seong Soo A. An 대한화학회 2009 Bulletin of the Korean Chemical Society Vol.30 No.1

        Thrombin activatable fibrinolysis inhibitor (TAFI) also known as plasma procarboxypeptidase B or U is a 60 kD glycoprotein, which is the major modulator of fibrinolysis in plasma. TAFI is a proenzyme, which is activated by proteolytic cleavage to an active carboxypeptidase B-like enzyme (TAFIa, 35.8 kD) by thrombin/thrombomodulin and plasmin. Modulation of fibrinolysis occurs when TAFIa enzymatically removes C-terminal lysine residues of partially degraded fibrin, thereby inhibiting the stimulation of tissue plasminogen activator (t-PA) modulated plasminogen activation. TAFIa undergoes a rapid conformational change at 37℃ to an inactive isoform called TAFIai. Potato tuber carboxypetidase inhibitor (PTCI) was shown to specifically bind to TAFIa as well as TAFIai. In this study, a novel immunoassay TAFIa/ai ELISA was used for quantitation of the two TAFI activation isoforms TAFIa and TAFIai. The ELISA utilizes PTCI as the capture agent and a double antibody sandwich technique for the detection. Low levels of TAFIa/ai antigen levels were detected in normal plasma and elevated levels were found in hemophilia A plasmas. TAFIa/ai antigen represents a novel marker to monitor fibrinolysis and TAFIa/ai ELISA may be a valuable assay for studying the role of TAFI in normal hemostasis and in pathological conditions.

      • KCI등재

        Recent Advances in the Detection of Methicillin Resistant Staphylococcus aureus (MRSA)

        John P. Hulme 한국바이오칩학회 2017 BioChip Journal Vol.11 No.2

        According to the World Health Organization (WHO) 20% of all documented S. aureus infections are attributable to MRSA, although for some developing countries this value can exceed 80%. Thus the rapid and accurate detection of MRSA in low resource settings (LDR) is becoming essential. Yet conventional microbial detection methods take from 1-5 days to identify MRSA. Recently, new types of automated laboratory methods as well as advances in nucleic acid testing, microfluidic technology, immunosensors, biosensors and point of care testing have reduced the time to detection to <1 hr. This review examines the current limitations and advances in methodologies employed in the rapid detection of MRSA.

      • KCI등재

        Extensive Resection for Treatment of Locally Advanced Primary Mucinous Adenocarcinoma Arising From Fistula-in-Ano

        Jordan Au,Francis M. Hulme-Moir,Andrew Herd,Mathew A. Kozman 대한대장항문학회 2021 Annals of Coloproctolgy Vol.37 No.S

        We report a case of a 66-year-old male who presented with a locally advanced primary mucinous adenocarcinoma arising from a fistula-in-ano. The presentation was typical for perianal sepsis and fistula-in-ano with anal pain and chronic discharge. Initial treatments with fistula debridement and seton were performed. Subsequent review of histology revealed underlying adenocarcinoma, while magnetic resonance imaging (MRI) showed local invasion into the prostate. The patient received neoadjuvant chemoradiotherapy followed by pelvic exenteration to maximize the chance of achieving cure. Features of this case are discussed together with its implications, including treatment guidelines and typical MRI findings.

      • Analysis of zinc oxide nanoparticles binding proteins in rat blood and brain homogenate

        Shim, Kyu Hwan,Hulme, John,Maeng, Eun Ho,Kim, Meyoung-Kon,An, Seong Soo A Dove Medical Press 2014 INTERNATIONAL JOURNAL OF NANOMEDICINE Vol.9 No.2

        <P>Nanoparticles (NPs) are currently used in chemical, cosmetic, pharmaceutical, and electronic products. Nevertheless, limited safety information is available for many NPs, especially in terms of their interactions with various binding proteins, leading to potential toxic effects. Zinc oxide (ZnO) NPs are included in the formulation of new products, such as adhesives, batteries, ceramics, cosmetics, cement, glass, ointments, paints, pigments, and supplementary foods, resulting in increased human exposures to ZnO. Hence, we investigated the potential ZnO nanotoxic pathways by analyzing the adsorbed proteins, called protein corona, from blood and brain from four ZnO NPs, ZnO<SUP>SM20(−)</SUP>, ZnO<SUP>SM20(+)</SUP>, ZnO<SUP>AE100(−)</SUP>, and ZnO<SUP>AE100(+)</SUP>, in order to understand their potential mechanisms in vivo. Through this study, liquid chromatography–mass spectroscopy/mass spectroscopy technology was employed to identify all bound proteins. Totals of 52 and 58 plasma proteins were identified as being bound to ZnO<SUP>SM20(−)</SUP> and ZnO<SUP>SM20(+)</SUP>, respectively. For ZnO<SUP>AE100(−)</SUP> and ZnO<SUP>AE100(+)</SUP>, 58 and 44 proteins were bound, respectively. Similar numbers of proteins were adsorbed onto ZnO irrespective of size or surface charge of the nanoparticle. These proteins were further analyzed with ClueGO, a Cytoscape plugin, which provided gene ontology and the biological interaction processes of identified proteins. Interactions between diverse proteins and ZnO nanoparticles could result in an alteration of their functions, conformation, and clearance, eventually affecting many biological processes.</P>

      • SCISCIESCOPUS
      • KCI등재

        Recent Trends in the Detection of Pathogenic Escherichia coli O157 : H7

        Si-Ying Wu,John P. Hulme,안성수 한국바이오칩학회 2015 BioChip Journal Vol.9 No.3

        The rapid and accurate detection of pathogenicEscherichia coli (E. coli) poses a significant healthproblem in both developed and developing countriesaround the world. Conventional microbial detectionmethods can take more than 48 hours to identify a pathogenic organism. Recently new types of nucleic acid chip based methods, microfluidic devices, signal amplification methods, immunoassays and biosensors have been developed capable of detecting very low concentrations of pathogenic E. coli in a few hours. This review examines the current limitations and recent advances in methodologies employed in the rapid detection of pathogenic E. coli O157 : H7.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼