http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이덕구,이행남,박길문 朝鮮大學校 機械技術硏究所 2001 機械技術硏究 Vol.4 No.1
The flow characteristics in dividing regions of rectangular duct system are precise, therefore their classification is very important not only in industry but also in hydrodynamics. By now, many studies of flow characteristics in dividing regions have been performed, but flow characteristics by visualizations in dividing regions have not been studied. The present Particle image velocimetry exhibits instant velocity distributions, kinetic energy distributions and vorticity, etc of the total flow fields due to the development of the accurate visualization with optical laser and optical equipment. Also, Particle image velocimetry is accurate with the flows characteristics of the dividing region as continuous analysis is done using input equipment. This study analyzes average velocity vector field, average kinetic energy and x-axis stress distribution of dividing regions with flow characteristics for visualization of Particle image velocimetry measurements in a dividing rectangular duct.
이병구,이상록,정덕양,권영호,김유현 高麗大學校 倂設 保健大學 保健科學硏究所 2002 保健科學論集 Vol.28 No.2
Under the various clinical circumstances, there is a condition to change source to skin distance(SSD). It is possible to correct photon beam by well-known inverse square law. On the other hand, the electron beam is not exact location of source, that's why it is difficult to apply as it is. In case of electron beam, we should correct the difference of SSD by measure effective SSD . There are many ways to measure effective SSD. In this study, Faiz Khan's method was used. The measurement energy is 6,9,12,16,20 MeV and field size is set standard applicator 6×6, 10×10, 15×15, 20×20, 25x25㎠. From the bottom of the standard applicator to skin distance is set to 5㎝. So we measured dose at the gap to 0∼20㎝. According to a production company of linear accelerator, or even though same production company, the qualities of electron beam can be different. So, effective SSD can be different every several accelerator. Therefore, it is desirable to use the effective SSD measured at every electron beam energy and field size actually.
이행남,박길문,모양우,이덕구,설재림,김건일 朝鮮大學校 機械技術硏究所 2004 機械技術硏究 Vol.7 No.2
The ejector is used to get low pressure, and it has been applied to a lot of industry field like the heat engine, the fluid instrument power plant, the food industry, environment industry etc. because there are not any problem even it is mixed with kinds of liquid, gas, and solid. The flow characteristics in diffuser are investigated by PIV and CFD. The agreement between numerical analysis and experiment shows the validity of this study and the results of this study would be useful to the engineers who design for the flow systems for heating, ventilation, air conditioning and wastewater purification plants.
김도태,이행남,박길문,이덕구,설재림 朝鮮大學校 機械技術硏究所 2004 機械技術硏究 Vol.7 No.1
The diffuser is used to get low pressure, and it has been applied to a lot of industry field like the heat engine, the fluid instrument power plant, the food industry, environment industry etc... because there are not any problem even it is mixed with kinds of liquid, gas, and solid. The flow characteristics in diffuser are investigated by prv and CFD. The experiment using PIV measurement for mixing pipe's flow characteristics acquired velocity distribution, .Condition : when mixing pipe's diameter ratio is 1:2.3, and the flux is Q₁ = 1.136 l/s, Q₂ = 1.706 l/s, Q₃ = 2.276 l/s . Based on the PIV and the CFD results, the flow characteristics in ejector are discussed, and it shows the validity of this study.
이행남,박길문,이덕구,정한별,김건일,설재림 朝鮮大學校 機械技術硏究所 2005 機械技術硏究 Vol.8 No.1
The sirocco fan is used to get low noise, and it has been applied to a lot of industry field like the heat engine, the fluid instrument power plant, the food industry, environment industry etc... because there are not problems even it is mixed with a any kind of liquid, gas, and solid. The flow characteristics in sirocco fan are investigated by PIV. The experiment using PIV measurement for Test section's flow characteristics acquired velocity distribution, Condition : when sirocco fan in automobile air controller maximum 1450RPM, and a revolution is a variation (l)950RPM, (2)l100RPM, (3) 1250RPM. The agreement a experiment shows the validity of this study and the results of this study would be useful to the engineers who design for the flow systems
요하지통 환자에서 두 개의 캐눌라를 이용한 박동성 고주파 신경근 응고술의 임상 연구
김천숙,배재영,배덕구,강규식,안기량,권진형,김지은,유시현 순천향의학연구소 2003 Journal of Soonchunhyang Medical Science Vol.9 No.1
Dorsal root ganglion(DRG) block by the local anesthetics and steroids which has done classically in low back pain(LBP) patients with radiculopathy has high incidence of recurrence rate and side effects of steroids. Recently a new technique of pulsed radiofrequency thermocoagulation(P-RFTC) was introduced and substituted for it because of the benefits such as relatively low recurrence rate, low risk of nerve injury and comfort during the procedure. We experienced 15 patients who had LBP with radiculopathy and no or little response to epidural steroid injection. When we performed DR ganglionotomy by P- RFTC under the C-arm guide in these patients, we tried to approach the exact DR ganglion using tow cannulas - the one for obtaining patient's subjective symptoms and injection of contrast dye, the other for making a RF lesioning after identifying the impedance of sensory and motor stimulation. In conclusion, DR ganglionotomy by P- RFTC using two cannulas in LBP patients is an easy and safe procedure with satisfactory results.
McCoy 세포에서 Chlamydia trachomatis의 병원성 인자에 관한 연구
강정숙,최지영,차영주,김영주,김덕례,여명구,박열 조선대학교 생명과학연구소 1998 생명과학 연구 Vol.6 No.-
본 연구는 병원성 세균인 Chlamydia trachomatis(C. trachomatis)가 숙주세포에침습시 C. trachomatis의 병원성 인자와 C. trachomatis와 상호작용하는 숙주 세포막의 인자를 규명함으로써 숙주세포에 대한 감염율을 향상시켜 보다 향상된 진단 방법을 개발하기 위하여 수행하였다. C. trachomatis로 감염된 세포에서 기본소체의 막 단백질을 분리한 결과 각 혈청형의 39 kDa과 42 kDa에서 major outer membranes(MOMPs)이 관찰되었으며, 혈청형 E와 G의 MOMPs는 42.5 kDa으로 동일하였지만 혈청형 F, H, I, 그리고 K의 MOMPs는 각각 다르게 관찰되었다. C. trachomatis가 숙주세포로 침습시 관련된 병원성 인자에 대하여 조사하고자 단층세포로 배양된 배양용기에 C. trachomatis를 24, 48 그리고 73시간대별로 접종시켜 관찰한 결과 72시간의 MOMPs의 양이 가장 많이 증가하였으며 이 결과로 MOMPS이 C. trachomatis 병원성에 중요한 작용을 함을 확인할 수 있었다. C. trachomatis가 침습시 숙주세포의 막 단백질 변화양상을 관찰하기 위해 정상세포와 C. trachomatis로 1, 2, 3 그리고 4시간대별로 접종 시간을 달리한 숙주세포의 막 단백질을 분리한 결과 42 kDa의 단백질 양이 Chlamydia에 감염된 세포 내에서 증가됨을 관찰할 수 있었다. 이로 42 kDa의 막 단백질이 침습시 숙주세포 표면에 대한 수용체로서 작용함을 알 수 있었다. The present study was performed to analyze the pathogenic factors involved in the invasion process of Chlamydia trachomatis(C. trachomatis) into McCoy cells. In this study, elementary bodies(EBs) of C. trachomatis serotypes(E, F, G, H, I, K and LGV) could be isolated by the method of Percoll density gradient centrifugation and the pathogens of serotypes were also compared from whole-cell lysates by using sodium dodecyl sulfate-polyacrylamide gel elelectrophoresis. All chlamydial serotypes showed a single predominant protein ranging from 39 to 42 kDa. The major outer membrane proteins(MOMPs) of the E and G serotypes had an identical molecular weight of 42.5 kDa. In contrast, the MOMPs of the F, H, I and K serotypes were showed different molecular weights of MOMPs. By immunoblotting with anti-MOMP antibody it was revealed that the quantify of MOMPs was time-dependently increased when McCoy cells were infected with Chlamydia for 24, 48 and 72 hr. These results indicated that MOMPs are closely related to chlamydial infection into the host cell.
이덕구(Duck-Gu Lee),박지만(Ji-Man Park),설재림(Jael-Lim Sul),이행남(Heang-Nam Lee),박길문(Gil-Moon Park) 한국마린엔지니어링학회 2004 한국마린엔지니어링학회 학술대회 논문집 Vol.2004 No.-
The Ejector is used to get low pressure, and it has been applied to a lot of industry field like the heat engine, the fluid instrument power plant. the food industry. environment industry etc... because there are not any problem even it is mixed with a any kind of liquid. gas. and solid. The flow characteristics in ejector are investigated by PIV and CFO. The experiment using PIV measurement for mixing pipe's flow characteristics acquired velocity distribution. .Condition: when mi:xing pipe's diameter ratio is 1:1.9. and the flux is Q1 = 1.136 I/s. Q2 = 1.706 I/s. Q3 = 2.276 I/s. Based on the PIV and the CFD results, the flow characteristics in ejector are discussed. and it shows the validity of this study.