        Linear Accelerator를 이용한 Stereotactic Radiosurgery

        정상섭,윤도흠,오성훈,김선호,서창옥,추성실,노준규,김동익,서정호 대한신경외과학회 1988 Journal of Korean neurosurgical society Vol.17 No.6

        A Modified irradiation technique utilizing a linear accelerator for radiation surgery within the brain was performed in 4 patients. Three of them had brain tumors and one small arteriovenous malformation in midbrain. A Hitchcock stereotactic apparatus and a 10 MeV linear accelerator have been adapted and special computer programs for dosimetry were obtained and studied experimentally with a phantom model. Stereotactic radiosurgery is a valuable tool in the treatment of inoperable, deep seated intracranial lesions, the major advantage being high efficacy and smoothness of the procedure, as well as short hospitalization times.

      • KCI등재

        High Energy Photon Dosimetry by ESR Spectroscopy in Radiotherapy

        Chu, Sung-Sil Korean Society of Medical Physics 1990 의학물리 Vol.1 No.1

        방사선치료에 가장 널리 사용하고 있는 Co-60 감마선과 6, 10 MV X-선등 다양한 에너지와 2 Gy 에서 10 Gy 의 조사선량 범위에 대한 정확한 선량측정은 방사선치료효과를 더욱 높힐수 있고 휴유증에 대한 선량평가에 도움을 줄 수 있다. 지금까지 방사선치료 범위에 속하는 방사선 계측은 주로 전리함을 사용하였으며 Build up cap 이나 팬텀을 이용하여 노출선량을 계측하고 계측된 값에 에너지에 따른 흡수선량 변환계수 , 측정기의 구성물질에 대한 저지능등 많은 변수를 고려해야하는 복잡성이 있으며 인체내의 선량분포측정이 어려웠다. 본실험에 사용한 Alanine 측정기는 아미노산의 일종인 유기물질로서 인체조직과 등가이고 부피가 작으므로 (0.5$\times$1cm) 조직내에 많이 삽입하여 방사선을 동시에 측정할 수 있었다. 방사선에 노출된 Alanine 은 구성분자의 일부분이 전리되어 장기간 Free radical 상태로 존재하며 마이크로파를 투과시키면 전자의 고유진동수와 일치된 전파를 흡수하는 전자스핀공명(Electron spin resonance) 이 일어나고 흡수된 전파의 강도를 측정함으로서 흡수선량을 추측할 수 있다. 방사선흡수선량 측정은 Co-60 원격치료장치의 선원에서 80cm 거리에 3개의 Alanine 측정기를 Build up holder 에 넣어 고정시키고 방사선치료 선량범위인 0.1Gy 에서 100 Gy 까지 조사하였으며 이때 ESR Spectra 의 진폭은 흡수선량에 비례하였고 선량 균일성의 표준편차는 2 Gy 에서 1% 이었으며 4 Gy 이상에서는 0.5% 이었다. 조직내 선량분포를 측정하기 위하여 인체구성과 같은 Rando phantom 내에 Alanine 측정기를 삽입하고 조사면과 에너지에 따른 방사선 흡수선량분포및 섬부율을 측정한 결과 표준 심부율과 일치하였다. 특히 Alanine 측정기는 온도 습도에 대한 변화가 적고 시간 경과에 대한 변화도 거의 없었으며 (년간 약 1% 감소 ) 에너지에 따른 변화도 없었기 때문에 치료방사선 영역의 선량 측정과 조직내 선량분포에 적당한 것으로 생각된다. The finding of long lived free radicals produced by ionizing radiation in organic crystals and the quantification of this effect by electron spin resonance(ESR) spactroscopy has proven excellent dosimetric applicability. The tissue equivalent alanine dosimeter also appear appropriate for radiation therapy level dosimetry. The dose measurement was performed in a Rando phantom using high energy photons as produced by high energy medical linear accelerator and cobalt-60 teletherapy unit. The absorbed dose range of the ESR/alanine dosimetry system could be extended down to 0.1 Gy. The response of the alanine dosimeters was determined for photons at different therapeutic dose levels from less than 0.1 Gy to 100 Gy and the depth dose measurements were carried out for photon energies of 1.25MeV, 6 and 10 MV with alanine dosimeters in Rando phantom. Comparisons between ESR/alanine in a Rando phantom and ion chamber in a water phantom were made performing depth dose measurements to examine the agreement of both methods under field conditions.

      • KCI등재
      • SCOPUSKCI등재

        Development and Thermal distribution of An RF capacitive Heating Device

        추성실(Sung Sil Chu),서창옥(Chang Ok suh),김귀언(Gwi Eon Kim),노준규(John Kyu Loh),김병수(Byung Soo Kim) 대한방사선종양학회 1987 Radiation Oncology Journal Vol.5 No.1

        환부에 열을 가하여 종양을 치료할 수 있는 온열요법의 생물학적 효과는 상당히 고무적이며 새로운 암 치료 수단으로 등장되었다. 그러나 체내 깊숙히 위치하고 있는 종양에 일정한 열을 계속 부여하면서 온도와 열의 분포를 정확히 측정하기가 어려웠다. 연세 암센터는 연세대학교 공과대학과 녹십자 의료 공업주식회사와 산학협동으로 라디오파 유전가열형 온열장치(가칭 Greenytherm-GY8)를 개발 제작하고 임상응용을 위해 기초 연구를 실시하였다. 개발된 온열장치는 8~10MHz 라디오파 발생기와 유전가열 전극, 온도계측용 열정대, 냉각장치 및 제어용 개인 컴퓨터로 구성되었다. 온열장치의 성능을 시험하기 위하여 인체크기의 한천팬텀과 동물 및 인체의 악성종양에 대한 치료온도와 온열분포를 측정하였다. 라디오파 발생전력을 200~l,500W까지 조절할 수 있으며 유전가열을 위한 라디오파의 주파수는 8~10MHz 범위를 얻을 수 있었다. 피부에 근접된 종양의 가열온도는 200~500W의 RF 전력으로 10분이 내 치료가능온도(42.5℃) 이상으로 가열할 수 있었으며 정상조직 쪽의 전극은 5~10℃로 냉각시키므로서 피부손상을 방지할 수 있었다. 5~10cm 깊이에 존재하는 종양의 가열온도는 치료 가능한 40~43℃까지 가열이 가능하였으며 냉각보러스와 정합회로에 의해 피부의 자극을 줄일 수 있었다. 이상과 같은 실험결과로 유전가열형 온열장치는 임상응용에 적합하다고 판단되며 임상경험을 통하여 더 예민한 정합장치와 전기적 자극을 완전히 줄일 수 있는 방법 및 편리한 전극 등의 개발이 가능한 기본자료가 될 수 있다. Hypertermia for the treatment of cancer has been introduced for a long time and the biological effect for the use of hyperthermia to treat malignant tumors has been well established and encouraging clinical results have been obserbed. Unfortunately, however, the engineering or technical aspects of hyperthermia for the deep seated tumors has not been satisfactory. We developed the radiofrequency capactive hyperthermia device (Greenytherm-GY8) in cooperation with Yonsei Cancer Center and Green Cross Medical Corporation. It was composed with 8~10MHz RF generator, capacitive electrode, matching system, cooling system, temperature measuring system and control PC computer. The thermal profile was investigated in agar phantom, animals and in human tumors, heated with capactivie RF device. Deep and homogeneous heating could be achieved in a large phantom of 25cm diameter and 19cm thick when heated with a pair of 23cm diameter electrodes, coupled to both bases of the phantom, when the size of the two electrodes was not the same, the region near the smaller electrode was preferentially heated. It was, therefore, possible to control the depth of heating by choosing proper size of electrodes. Therapeutic temperature (42℃~43℃) could be obtained in the living animal experiments. Indications are that deep heating of humn tumors might be achieved with the capacitive method, provided that subcutaenous fat layer is cooled by temperature controlled bolus and large size of electrodes.

      • SCOPUSKCI등재

        Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer

        추성실(Sung Sil Chu),노준규(John JK Loh),김귀언(Gwi Eon Kim) 대한방사선종양학회 1992 Radiation Oncology Journal Vol.10 No.1

        4-5MeV의 전자선은 피부표면의 흡수선량을 증가시키고 표면하 10mm 내외에서 급속히 감소함으로 Mycosis fungoides, Kaposi's sarcoma등 전신피부암에 대한 가장 적당한 치료방사선으로 알려져왔다. 그러나 평면이 아니고 굴곡이 심한 인체표면에 균일한 선량을 계획하기는 많은 어려움이 있었다. 연세암센터에서는 1980년부터 시행하여왔던 6MeV 전자선의 마름모형, 네방향 조사방법을 개량하고 많은 문헌을 참고하여 상하 양방향의 조사면과 환자위치를 각각 여섯가지 자세로 나누어 조사(Six-Dual-Field)하는 방법을 사용하였으며 이에따른 전신피부표면의 선량과 선량분포를 측정하였다. 선형가속기에서 발생되는 6MeV 전자선을 0.5cm 두께의 아크릴판으로 감약시키고 콜리메터가 완전히 열린 조사면을 상하 19°씩 옮기므로서 타켓트에서 3m 거리에 약 2m×1m의 균일한선량의 조사면(평탄도 +3%)과 10mm 내외의 실효깊이(80% 선량지점) 및 산란선에 의한 피부표면선량을 증가시킬 수 있었다. 환자는 일부피부가 가려지지않도록 팔과 다리를 적당한 자세로 고정시키고 전자선을 여섯방향에서 각각 2회씩 상하로 조사시키므로서 피부표면에 균일한 선량분표(표준편차 5%)가 가능하였으며 80%의 심부률이 8~10mm에서 측정되었다. 모든 측정은 인체등가팬텀과 폴리스틸렌팬텀을 사용하였으며 필름, 평형전리측정기 및 표준전리측정기를 이용하였다. 특히 환자피부표면의 흡수선량분포를 확인하기 위하여 열형광측정기와 반도체측정기를 이용하였으며 6~20개의 소형 측정기를 환자 피부표면에 부착시킨후 전자선 치료과정 동안 피폭 시켜 측정하였고 그결과 차폐된 부위를 제외하고 평균 10%이내의 균일한 선량분포를 얻을 수 있었다. Increasing frequency of skin cancer, mycosis fungoides, kaposi's sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a 0.5cm×90cm×180cm acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six different positions due to be homogeneous dose distribution for whole skin around the body. One treatment session delivered 400 cGy to the entire skin surface and patients were treated twice a week for eight consecutive weeks, which is equivalent to TDF value 57. Instrumentation and techniques developed in determining the depth dose. dose distribution and bremsstrahlung dose are discussed.

      • SCOPUSKCI등재

        방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정

        추성실(Sung Sil Chu),김귀언(Gwi Eon Kim) 대한방사선종양학회 1996 Radiation Oncology Journal Vol.14 No.1

        목적: 다엽콜리메이터를 이용하여 부정형의 치료부위를 편리하고 정확히 차페하며, 삼차원 입체조형치료를 원활히 수행하기 위하여 다엽콜리메이터의 차폐특성을 계측하고 치료계획을 위한 최적방법을 확정한다. 대상 및 방법 : 차폐폭이 1cm이고 길이가 15cm인 52개의 금속차폐엽들이 양방향 각각 26개로 구성되어 컴퓨터계획에 의거 여러모양의 차폐면을 구사할 수 있는 다엽콜리메이터(Multileaf collimator)를 대상으로 방사선 치료에 요구되는 고에너지 방사선의 출력선량을, 차폐및 투과효과, 반음영, 조직내 선량 분포등을 전리함측정기와 열형광측정기 및 필름 선량측정방법을 이용하여 계측하였다. 다엽콜리메이터의 계단식 반음영 측정은 고체팬텀과 비디오밀도측정기를 이용하여 실효반음영(Effective penumbra)과 일반적반음영General penumbra)으로 구분 평가하였다. 결과 : 다엽콜리메이터의 출력선량율은 표준차폐조리개에 비교하여 출력 선량율 이 1-2%증가 되었으며 치료오차 이내로 평가되었다. 다엽콜리메이터의 방사선투과 선량율은 6-10MV X선에서 평균2%로 표준 차폐조리개보다 컸지만 혼합차폐벽돌보다 적었다. 원형으로 형성된 차폐엽 끝 면의 조사선량은 약20%증가 되었으며 엽과 엽사이의 선량은 6mm폭의 5%증가로 심부치료에 영향이 없었다. 다엽콜리메이터의 실효반음영(20-80%)은 약6mm로서 혼합차폐벽돌과 거의 같았으나 중심선에서 벗어날수록 2-3%증가되었다. 다엽콜리메이터에 의한 계단식 모양의 반음영은 6-10MV x-선에서 차폐면 경사각이 45도일 때 약 11mm로 가장 컸으며 방사선속에 평행히 절단된 차폐벽돌보다 약 5mm더 증가되었다. 결론 : 다엽콜리메이터는 1cm폭의 차폐엽들로 구성되어 계단식 차폐면에 대한 반음영이 다소 증가되고 있지만 조직내부의 다문조사 경우 반음영이 완화되므로 부정형 조사면 차폐에 적당하며 방사선 입체조형치료를 수행할 수 있는 가장 적당한 차폐기구로 생각된다 Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radiotherapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required. For modeling the collimator with treament planning software. detailed dosimetric characterization of the multilef collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. Materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution. Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6&10 MV x-ray energies. approximately 2.0% of photons incident on the multileaf collimator were transmitted and an additional 0.5% leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the 50% decrement line and this difference is attributed to the curved shaped end on the leaves. One side of a single leaf corresponded to the 50% decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove rsed to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sioping field, the isodose lines follow the leaf pattern and produce scallopoing isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small(5mm). Conclusion : Using the characteristic data of MLC. the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

      • SCOPUSKCI등재

        Optimization of Dose Distribution for High Dose Rate Intraluminal Therapy

        추성실(Sung Sil Chu),김귀언(Gwi Eon Kim),노준규(Juhn Kyu Loh) 대한방사선종양학회 1994 Radiation Oncology Journal Vol.12 No.2

        원격조종 아프터로딩에 의한 고선량율 관내삽입조사는 체내 발생된 종양에 방사선원을 근접시켜 치료하는 방사선요법으로서 신속한 선량계산과 선량의 정확성 및 다양한 모양의 최적선량분포가 요구된다. 저자들은 크기가 작고 선량율이 높은 고선량율의 방사성동위원소에 대한 정확한 조사선량과 최적선량분포를 얻기 위하여 수학적인 콤퓨터 계산프로그램과 실측으르서 비교하였다. 고선량율 선원에 의한 방사선 조사선량과 조직내 흡수선량분포의 각각 Sievert적분식과 Meisberger의 다항식을 이용하여 작성하였다. 종양크기와 모양에 가장 알맞는 선량분포의 최적화를 실현하기 위하여 저자들은 치료기준점의 선량을 일정한 값으로 고정시키고 선원의 조사시간을 조정하는 선형반복 계산방정식을 이용하였다. 모형선원이 장착된 아프터로딩관을 삽입하고 조준엑스선으로 촬영하여 종양부위를 결정한 후 콤퓨터의 도움으로 아프터로딩관의 축과 평행선 등량곡선 또는 과일모양의 선량분포 및 기관지 모양의 등선량 분포가 성취되도록 선량최적화를 시행하였고 선량계에 의한 실측치와 오차가 3%이하로 잘 일치하였다. The use of high dose rate remote afterloading system for the treatment of intraluminal lesions necessitates the need for a more accurate of dose distributions around the high intensity brachytherapy sources, doses are often prescribed to a distance of few centimeters from the linear source, and in this range the dose distribution is very difficult to assess. Accurated and optimized dose calculation with stable numerical algorithms by PC level computer was required to treatment intraluminal lesions by high dose rate brachytherapy system. The exposure rate from sources was calculated with Sievert integral and dose rate in tissue was calculated with Meisberger equation. An algorithm for generating a treatment plan with optimized dose distribution was developed for high dose rate intrauminal radiotherapy. The treatment volume becomes the locus of the constrained target surface points that is the specified radial distance from the source dwelling positions. The treatment target volume may be alternately outlined on an x-ray film of the implant dummy sources. The routine used a linear programming formulism to compute which dwell time at each position to irradiate the constrained dose rate at the target surface points while minimizing the total volume integrated dose to the patient. The exposure rate and the dose distribution to be confirmed the result of calculation with algorithm were measured with film dosimetry, TLD and small size ion chambers.

      • SCOPUSKCI등재

        Disign and Thermal Distribution of Intra-hyperthermia Microwave Antennas for U tero-cervical Applicators

        추성실(Sung Sil Chu) 문성록(Sun Rock Moon) 대한방사선종양학회 1990 Radiation Oncology Journal Vol.8 No.1

        자궁암치료에서 재발되거나 치료가 어려운 종양에 대하여 방사선과 온열요법을 병행함으로서 치료성과를 다소 향상시킬 수 있었다. 더욱이 방사선 근접조사와 강내온열치료는 주위 건강조직의 피해를 줄이면서 종양에 집중 손상을 줄 수 있었으며 강내방사선조사 기구를 공동으로 이용하므로서 시술이 간단하고 치료부위를 정확히 조준할 수 있었다. 그러나 강내조사용 안테나는 그 모양과 구성에 따라 온열 분포가 변하며 재래식 쌍극철심형 안테나는 끝부분 또는 연결부위의 가온이 급증하여 균등한 온열분포를 기대할 수 없었다. 저자들은 안테나의 길이를 마이크로파의 약수 즉 3,6,12cm로 하여 공명이 잘 이루어지도록 하였으며 끝이 굵고 접촉 부위가 가느다란 고깔형(conical) 안테나를 제작하여 사용한 결과 안테나 축에 따라 거의 일정하거나 약간 타원형의 온도분포를 이우었으며 가온 깊이도 2~3 cm로서 비교적 깊은 곳까지 가열할 수 있어 강내 치료효과를 향상시킬 수 있다고 생각된다. Intracavitary brachytherapy combined hypertermin for utero-cervical cancer seems to be a promising method for salvage treatments in persistent tumors and inoperable or Previously irradiated cervical recurrences. In order to heat the vaginal apex and uterus, powerfull conical antennas which are suitable for afterloading cervical applicator have been designed for use in conJuction with intracavitary radiation therapy. The antennas were constructed with conical conductive material to feed line and the effective length were designed proportional to microwave length, Power deposition profiles of 2450 MHz of conical antennas were studied in both phantom models and muscle tissue and compared to those of commonly used dipole antenna. Improvement of the heating pattern was found in both phantom and muscle tissue. The heating pattern produced by the conical ant na resembles an ellipsoid and then the temperature distribution in depth was extended to 2 ~ 3 em from the effective antenna axis.

      • SCOPUSKCI등재

        The Enhancement of Skin Sparing by Tray Materials for High Energy Photon Beam

        추성실(Sung Sil Chu),이창걸(Chang Geol Lee),김귀언(Gwi Eon Kim) 대한방사선종양학회 1993 Radiation Oncology Journal Vol.11 No.2

        종양치료를 위하여 고에너지 X-선 또는 감마선을 인체에 조사할 경우 피부 표면 선량이 최대지점 선량의 30~60%에 불과 함으로 피부보호 효과(Skin sparing effect)를 얻을 수 있는 장점을 갖고있다. 그러나 종양특성과 발병위치에 따라 조사면을 크게 하거나 선속내에 차폐물질 또는 보상여과판을 설치하여 치료할 경우 피부보호 효과가 감소되거나 없어지는 경우가 있고 이것은 종양치료에 중요한 요인이 되고 있다. 연세 암전문병원에 설치된 코발트 60원격치료기와 선형가속기에서 발생되는 4 MV및 10 MV x-선에 대한 피부선량을 측정하였으며 차폐물고정판(Tray) 구성 물질의 종류와 조사면의 크기 및 피부와 고정판간의 거 리에 따른 피부선량의 변화를 평가하였다. 방사선 조사면이 15x15㎠ 이상 넓고 피부와 collimator 간의 거리가 30 cm 이상일 때 피부 표면선량은 코발트 -60, 4, 10 MV에서 각각최대선량의 40, 30, 20%로 감소하였으며 조사면의 크기와 차폐 고정판의 물질에 따라 증감하였다. 차폐물을 고정시키는 고정판을 Lucite로 제작하고 고정판과 피부간의 거리를 약 15 cm 이상 간격을 주면 표면선량을 50%로 줄일 수 있었고 주석, 구리, 납등을 부착시키면 전방산란 선량비율이 감소되어 피부선량은 35%로 피부보호 효과를 얻을 수 있었다. 방사선의 전방산란비율은 에너지와 흡수물질의 원자번호에 관계되며 납과 주석 이 각각 코발트-60 감마선과 4~10 MV x-선의 전방산란비를 가장 크게 감소시켰다. The skin sparing effect associated with high energy x-ray or gamma ray beams may be reduce or lost under certain conditions of treatment. Current trends in using large fields. Shield carrying trays, compensating filters, and isocentric methods of treatment have posed problems of increased skin dose which sometimes become a limiting factor in giving adquate tumor doses. We used the shallow ion chamber to measure the phantom surface dose and the physical treatment variables for Co-60 gamma ray, 4MV and 10 MV x-ray beam. The dependence of percent surface dose on field sizes, atomic number of the shielding tray materials and its distance from the surface for 4, 10MV x-rays and Co-60 gamma ray is qualitatively similar. The use of 2 mm thick tin filter is recommended for situations where a low atomic number tray is introduced into the beam at distances less than 15 cm from the surface and with the large field sized for 4 MV x-ray beam. In case of Co-60 gamma ray, the lead glass tray is suitable for enhancement of skin sparing. Also, the filter distance should be as large as possible to achieve substantial skin sparing.

      • SCOPUSKCI등재

        High Energy Electron Dosimetry by Alanine/ESR Spectroscopy

        추성실(Sung Sil Chu) 대한방사선종양학회 1989 Radiation Oncology Journal Vol.7 No.1

        물질에 방사선을 조사시키면 구성원자 또는 분자의 일부분이 전리되며 특수한 유기화합물은 장기간 free radical상태로 존재하고 그 밀도는 조사된 방사선량에 비례한다. Free radical상태의 물질에 마이크로파와 같은 전자파를 투과시키면 free radicl된 전자의 고유진동과 일치된 전자파를 흡수하는 전자스핀공명(Electron Spin Resonance)이 일어나며 흡수된 전파의 강도를 측정함으로서 조사된 방사선량을 추측할 수 있다. ESR를 이용한 free radical dosimeter로서 가장 잘 알려진 물질이 아미노산 alanine이므로 이것과 파라핀 10%를 혼합하여 0.4x1cm의 alanine dosimeter를 제작하였다. 측정 방법은 방사선 흡수선량을 직접 측정할 수 있도록 조직등가인 물 팬텀과 방수된 Alanine dosimeter holder를 제작하고 의료용 선형가속기에서 발생되는 6~21MeV전자선을 조사하면서 최대 흡수 선량과 깊이에 따른 선량분포를 측정하였다. 전자선 조사선량은 1 Gy에 60Gy까지의 방사선 치료선량 범위를 선택하였으며 측정결과 전자선량 증가에 따라 ESR신호의 진폭이 선형비례적으로 증가하였다. 그러나 전자선량이 4Gy이하에서는 alanine dosimeter의 선량 균일성이 ±2~4%(표준편차)의 오차가 있었으며 4Gy이상에서는 ±1% 이하의 오차를 나타냄으로서 환자에 대한 전자선 조사량 범위인 1Gy에서 60Gy까지의 흡수선량을 정확히 측정할 수 있었다. 측정한 결과 전자선 에너지 12MeV이하에서는 전리상으로 측정 계산된 선량과 일치하였지만 15MeV이상에서는 표면에서 깊이 2cm까지의 흡수선량이 약2~5%가 높았다. 이와 같은 현상은 의료용 선형가속기의 전자선 방출구에 장착된 산란판과 조사면을 조정하는 cone에 의하여 발생되는 저 에너지 산란전자선이 alanine dosimeter에 측정된 것으로서 에너지가 증가될수록 오염 정도가 증가되었다. 본 실험을 통하여 지금까지 고에너지 전자선량계측에서 전리상에 의한 전기량 측정과 산란선이 없는 단일 에너지로만 간주하여 계산하였던 전자선 흡수선량 측정방법을 직접 흡수선량 측정이 가능한 Alanine/ESR dosimetry로서 교정하는 것이 바람직하다고 생각한다. Dosimerty based on electron spin resonance (ESR) analysis of radiation induced free radicals in amino acids is relevant to biological dosimetry applications. Alanine detectors are without walls and are tissue equivalent. Therefore, alanine ESR dosimetry looks promising for use in the therapy level. The dose range of the alanine/ESR dosimetry system can be extended down to 1 Gy, in water phantom the absorbed dose of electrons generated by a medical linear accelerator of different initial energies (6~21MeV) and therapeutic dose levels (1~60 Gy) was measured. Furthermore, depth dose measurements carried out with alanine dosimeters were compared with ionization chamber measurements. As the results, the measured absorbed doses for shallow depth of initial electron energies above 15MeV were higher by2~5% than those calculated by nominal energy CE factors. This seems to be caused by low energy scattered beams generated from the scattering foil and electron cones of beam projecting device in medical linear accelerator.