Sealer의 사용이 임프란트 나사의 안정성에 미치는 영향
이흥태,김낙형,정재헌,Lee Heung-Tae,Kim Nak-Hyung,Chung Chae-Heon 대한치과보철학회 2001 대한치과보철학회지 Vol.39 No.4
The objective of this study was to investigate the surface contact and screw joint stability between screw and implant interface by use of sealer. The implants evaluated in this study were Steri-Oss futures(Hexlock $3.8D{\times}10mm$: Steri-Oss, Yorba Linda, CA), and Steri-Oss staight abutment. Titanium alloy screws were used to secure abutments to implants. The other titanium alloy screws applicating sealer(Impla-Seal, Implant Support Systems, Inc. Irvine, CA) were used to secure abutments to implants. In one another sample, 6kg of force was applied during simulated intraoral movements after abutment screws were secured to the implants with sealer. All samples were cross sectioned with sandpaper and polished with $0.1{\mu}m\;Al_2O_3$. Then samples were recorded with an scanning electron microscope. The results were as follows : 1. In the case of titanium alloy screw, irregular contacts and relatively large gap were present at thread mating surface. Also abutment screw/implant interface demonstrate incomplete seating and only one surface contact of threads between implant and screw. 2. In the case of titanium alloy screw applecating sealer, sealer was present between implant and screw. Therefore implant and screw had relatively close and tight contact without the presence of large gap. 3. On the other hand, in the case of titanium alloy screw applicating sealer and dynamic loading of suprastructures, sealer was partially present between implant and screw. Conclusively, sealer fills voids, creating a barrier to moisture and bacteria. In addition, loading of suprastructures may change the situation and limit the indications for gap sealing.
내측연결 임플란트 시스템에서 고정체와 지대주 연결부의 적합에 관한 연구
이흥태,정재헌,Lee Heung-Tae,Chung Chae-Heon 대한치과보철학회 2004 대한치과보철학회지 Vol.42 No.2
Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Paragon system were used. Each abutment was connected to the implant with 32Ncm torque value using a digital torque controller or tapping. All samples were cross-sectioned with grinder-polisher unit (Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc). Then optical microscopic and scanning electron microscopic(SEM) evaluations of the implant-abutment interfaces were conducted to assess quality of fit between the mating components. Results : 1) Generally, the geometry of the internal connection system provided for a precision fit of the implant/abutment into interface. 2) The most precision fit of the implant/abutment interface was provided in the case of Bicon System which has not screw. 3) The fit of the implant/abutment interface was usually good in the case of ITI, 3I and Avana system and the amount of fit of the implant/abutment interface was similar to each other. 4) The fit of the implant/abutment interface was usually good in the case of Friadent, Astra and Paragon system. The case of Astra system with the inclined contacting surface had the most Intimate contact among them. 5) Amount of intimate contact in the abutment screw thread to the mating fixture was larger in assembly with two-piece type which is separated screw from abutment such as Friadent, Astra and Paragon system than in that with one-piece type which is not seperated screw from abutment such as ITI, 3I and Avana system. 6) Amount of contact in the screw and the screw seat of abutment was larger in assembly of Friadent system than in asembly of Astra system of Paragon system. Conclusion: Although a little variation in machining accuracy and consistency was noted in the samples, important features of all internal connection systems were the deep, internal implant-abutment connections which provides intimate contact with the implant walls to resist micro-movement, resulting in a strong stable interface. From the results of this study, further research of the stress distribution according to the design of internal connection system will be required.
이흥태,구철인,박찬익 朝鮮大學校 口腔生物學硏究所 2002 口腔生物學硏究 Vol.26 No.1
Polymers are the dominant material for fabrication of denture base. However, resin base can't fufill the patients' satisfactions completely and solve the pronunciation problem and prevent the denture fracture. In spite of many advantages, metal denture bases do not widespread in clinical practics. The main reasons are the difficulties in fabrication and additional time and cost, inability to rebase such prostheses. The use of the metal base can be one of options in complete denture treatments. This study helps, through reveiwing previous reports and literature about the metal base, metal base to be useful in the clinical application by recommend the materials, indications and advantage/disadvantage of the metal base and introduce variable designs. The clinical application of the metal base have many advantages. but the dentists have to select cases carefully and apply designs according to patient's various conditions. In conclusion, the use of the metal base can't alternate treatment of inadequate conventional complete denture. Adequate complete denture is very important for the treatment of the metal base complete denture.