RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        유연체 로터-커플링-블레이드 시스템의 로터 축과 블레이드의 연성 진동에 관한 연구

        오병영(Oh, Byung-Young),이선숙(Lee, Sun-Sook),윤형원(Yoon, Hyungwon),차석주(Cha, Seog-Ju),나성수(Na, Sungsoo) 한국소음진동공학회 2005 한국소음진동공학회 논문집 Vol.15 No.9

        In this paper, a dynamic model for the rotor shaft-coupling-blade system was developed. The blades are attached to a disk and driven by an electric motor shaft which is flexible in torsion. We assumed that the shaft torsional flexibility was lumped in the flexible coupling which is usually adopted in rotor systems. The Lagrangian approach with the small deformation theory for both blade-bending and shaft-torsional deformations was employed for developing the equation of the motion. The Assumed Modes Method was used for estimating the blade transverse deflection. The numerical results highlight the effects of both structural damping of the system and the torsional stiffness of the flexible coupling to the dynamic response of the blade. The results showed strong coupling between the blade bending and shaft torsional vibrations in the form of inertial nonlinearity, stiffness hardening and softening.

      • KCI등재

        자연 방사선량 중 ²²²Rn 기여 성분 정량 해석

        병영,채하석,전재식,오희필,김도성 대한방사선 방어학회 1989 방사선방어학회지 Vol.14 No.2

        옥외 라돈이 호흡기관에 주는 선량을 측정·평가할 목적으로 CR-39 비적검출기를 내장한 라돈컵을 사용하여 대기중 라돈농도를 측정하였다. 직접형 검출기 및 개방 컵과 필터 컵의 구조를 갖는 CR-39비적검출기에 대한 라돈검출인자는 공기중의 농도가 잘 알려진 표준라돈 조사시설에서 이들 검출기와 라돈컵을 일정기간 조사하여 결정하였다. CR-39를 70°c, 30% NaOH용액으로 220분간 화학부식하였을 때 직접형 거출기와 개방 컵, 필터 컵에 대한 라돈검출인자는 각각 0.273, 0.0813, 0.0371tr mm-2/37 Bqm-3·d)였다. 또한 1988년 5월에서 1989년 3월까지 대전(충남대학교)에서 측정한 대기중의 라돈농도는 개방 컵에 의한 결과는 27.4 - 135.8Bq/m3(0.74 - 3.67 pCi/l)로서 연평균 73.3 Bq/m3(1.98 pCi/l)이었으며, 필터 컵에 의한 결과는 16.7 - 143.9 Bq/m3(0.45 - 3.89 pCi/l)로 연평균 68.5 Bq/m3(1.85 pCi/)이었다. 측정한 옥외 대기중이 라돈농도와 부위별 폐선량모형으로부터 산출한 ICRP표준인의 호흡기관에 대한 실효 선량당량률은 약 520 nSv/h로 평가되었다. A study for the assessment of dose given by outdoor radon to respiratory system has been carried out by making use of radon-cups containing CR-39 plastic track detectors. Detection efficiencies were determined by irradiation of the radon-cups in a standard radon chamber of known concentration. Thus determined detection factors of CR-39 plastic track detector in bare, open cup and filtered cup geometry are found to be 0.273, 0.0813 and 0.0371 trmm-2/(37 Bqm-3 d), respectively, which are chemically etched in 30% NaOH solution of 70℃ for 220 minutes. The outdoor radon concentrations measured at Taejeon (Chungnam National University) from May 1988 to March 1989 are in the range of 27.4 - 135.8 Bq/m3 (0.74 - 3.67pCi/l) by open cup and 16.7 - 143.9 Bq/m3 (0.45 - 3.89pCi/l) by filtered cup, which yield overall annual average value of outdoor radon concentration of 70.8 Bq/m3 (1.91 pCi/l). Corresponding effective dose equivalent rate to respiratory system of ICRP standard man is assessed to be 520nSv/h.

      • 자연방사선량중 ^222 Rn 기여성분 정량해석

        전재식,오희필,채하식,병영,김도성 충남대학교 기초과학연구소 1989 연구논문집 Vol.9 No.-

        옥외 라돈이 호흡기관에 주는 선량을 측정·평가할 목적으로 CR-39 비적검출기를 내장한 라돈 컵을 사용하여 대기중 라돈농도를 측정하였다. 직접형 검출기 및 개방 컵과 필터 컵의 구조를 갖는 CR-39 비적검출기에 대한 라돈검출인자는 공기중의 농도가 잘 알려진 표준라돈 조사시설에서 이들 검출기와 라돈컵을 일정기간 조사하여 결정하였다. CR-39를 70℃, 30% NaOH용액으로 220분간 화학부식하였을 때 직접형 검출기와 개방 컵, 필터 컵에 대한 라돈검출인자는 각각 0.273, 0.0813, 0.0371 tr㎜^-2/(37Bqm^-3·d)였다. 또한 1988년 5월에서 1989년 3월까지 대전(충남대학교)에서 측정한 대기중의 라돈농도는 개방 컵에 의한 결과는 2.74-18.87Bq/㎥(0.07-0.5pCi/ℓ)로서 연평균 8.25Bq/㎥(0.22pCi/ℓ)이었으며, 필터 컵에 의한 결과는 1.67-19.76Bq/㎥(0.05-0.54pCi/ℓ)로 연평균 8.18q/㎥(0.22pCi/ℓ)이었다. 그리고 대기중의 라돈농도에서 ^(220)Rn의 기여성분은 무시할 수 있을 정도인 것으로 판단되었다. 측정한 옥외 대기중의 라돈농도와 부위별 폐선량모형으로부터 ICRP 표준인의 호흡기관에 대한 유효선량당량률은 약 60nSv/h(0.5mSv/y)로 평가되었다. A study for the assesssment of dose given by outdoor radon to respiratory system has been carried out by making use of radon-cups containing CR-39 plastic track detectors. Detection efficiencies were determined by irradiation of the radon-cups in a standard radon chamber of known concentration. Thus determined detection factors of CR-39 plastic track detedtor in bare, open cup and filtered cup geometry are found to be 0.273, 0.0813 and 0.0371tr㎜^-2/(37Bqm^-3·d) respectively, which are chemically etched in 70℃, 30% NaOH for 220 minutes. The outdoor radon concentrations measured at Taejeon(Chungnam National University) from May 1988 to March 1989 are in the range of 2.74-18.8Bq/㎥(0.07-0.51pCi/l) by open cup and 1.67-19.76Bq/㎥(0.05-0.54pCi/l.) by filtered cup. The annual averaged value of the measured outdoor radon concentration is 8.2Bq/㎥(0.22pCi/l). Corresponding effective dose equivalent rate to respiratory system of ICRP standard man is assessed to be 60nSv/h or 0.5mSv/y.

      • Gerbera(Gerbera hybrida Hort)의 형태적 특징과 유전적 유연관계 분석

        김현애,임현희,양원진,이재헌,병영,이용문,권오창 동아대학교 농업생명과학연구소 2001 農業生命資援硏究 Vol.10 No.1

        This study was conducted to analyze the morphological characteristics and genetic relationships among 24 species of Gerbera. Most of flower colors were pink. The numerical order of flower color was pink, orange, red, double-colored, and milk-white. Majority of flower types were single or semidouble flowers. A few species were double flowers. Flower diameters were from 7cm to 12cm, showed significant differences compared to other characteristics. Flower stalks were ranged from 55cm to 65cm. Only one species was the shortest as 55cm. The others were similar size as about 65cm. Main annual production yields were between 190 and 400 blossoms. Fifty seven reproducible polymorphic bands from eighty primers were used for analyses of genetic similarity. The genetic similarity of 24 collected Gerberas was largely classified into five groups. The average similarity coefficient was 0.72 ranged from 0.50 to 0.90. The highest similarity coefficient was shown between 'Sardana' with red/white flower color and double flower type, and 'Tamara' with orange flower color and double flower type as 0.90.

      • Cs-137 γ-선 조사장치의 방사선장 해석연구

        전재식,채하석,이철영,오장진,병영,명동범 충남대학교 기초과학연구소 1995 忠南科學硏究誌 Vol.22 No.1

        In reference to the ISO-4037 and ANSI N13.11, appropriateness of the shielding and collimating system, and suitability of the irradiation and its environmental conditions of a 20 Ci Cs-137 gamma-ray irradiator installed in Korea Institute of Nuclear Safety(KINS) were investigated. Upon the installation of the irradiator, condition of collimator alignment and virtual beam cross section were examined by use of a portable He-Ne laser. In order to evaluate the fitness of the secondary(scattered) to primary ratio of the collimated gamma-ray beam from the irradiator in light of ISO and ANSI requirement, the measurements of the secondary to primary ratio were performed by use of a cavity type ion chamber which had been calibrated in a calibration laboratory that maintains reliable traceability. For the theoretical assessment of the gamma-ray field the collimated beam were divided into fifteen sectors and for each sector the secondary to primary ratio and the gamma-ray spectrum was simulated by means of Monte Carlo method. The outcomes were compared with the experimental results, and cause of scattering and the existence of alleged modifying factors in the irradiator were examined.

      • 벡터 위상의 구성에 관한 소고

        오정균,병영 순천향대학교 기초과학연구소 1998 순천향자연과학연구 논문집 Vol.4 No.1

        Let X be a Vector space over K, Let β be an additive filterbase of balanced absorbing subsets of X. Then there is a unique vector topology T for X which β is a local base of neighborhood of 0. Say addition + : X × X → X ( ( x, y ) → x + y ) is continuous and scalar multiplication · : K × X → X ( ( t, x ) → t x ) is continuous.

      • 의료방사선관리의 국제화 연구 : 핵의학분야의 의료방사선관리

        김인규,오헌진,김혁주,오현주,박기정,이광용,병영,정승환,강영규,이현구,김귀야,한상용,김연교,양현규,이명철 식품의약품안전청 2001 식품의약품안전청 연보 Vol.5 No.-

        의료방사선은 인간의 질병진료와 예밤에 활용되어 각종 질병으로부터의 적절한 진단 및 의학발전에 중대한 역할을 담당하고 띤다. 또한 인공방사선원중 가장 큰 비중을 차지하고 있으며, 방사선원을 이웅한 이득과 손실을 생각쌀 때 피폭선량의 최소화 및 곡률적영향의 최소화를 위해 이득을 최대화하는 노력을 하고 있다. 진단뿐만 아니라 치료에도 사응하고 있는 인공방사선원의 적절한 관리를 위한 조사 및 연구는 국내에서는 아픽까진 실시되지 않았으며, 국외에서는 이미 활발한 조사 덴 연구가 이루어 지 고 있다. 일반적으로 의료기관의 핵의학분야에서 환자의 진단 및 치료에 사용되는 방사성의약품으로는 Tc-99in, Ga-67, 1-131, 71-201 등이 있으며 이를 이용한 방사능측정웅장비 및 치료뭉장비에는 Gamma Camera, 감마선재측기, 베타선계측기, Dose CaTibrator, PET(양전자방출전산화단층촬영장치)등이 있다. 이어 식푿의약품안전청f"서는 핵의학분야의 방사선보건학적 연구를 위해 핵의학분야의 진료와 관련된 인력, 시설, 장비, 방사성의약품의 사응, 핵의학적 진료형태 및 핵의학적 진료장치에 대한 성능관리등에 대해 조사·연구하였다. A nationwide survey was conducted in the Korea in 2001 to determine the facilities available and the level of activity at centres where radionuclide and therapy was practised in 2000. A response rate of 75% indicated that 120 centres were providing radionuclide therapy and diagnosis. About the good treatment of radionuclide using in medical, researched so many country, but not yet in. Generally nuclear medical part use Tc-99m, Ga-67, I-131, Tl-201 in diagnosis and therapy, radiation detector and equipment for therapy use Gamma Camera, beta-counter, Dose Calibrator PET(Positron Emission Tomography). 81% rate of centre has Gamma Camera and 97% rate of use Tc-99m, I-131 radionuclide. In-vitro did more than in-vivo test absolutely. So in KFDA researched in unclear medical part in Man-Power, facilities, equipment use of nuclear medicine, part of diagnosis and diagnosis equipment.

      • 진단용 X-선장치의 성능관리를 위한 검사방법 개선에 관한 연구(Ⅱ)

        김인규,김혁주,오현주,이광용,김지순,심선보,병영,남정우 식품의약품안전청 2000 식품의약품안전청 연보 Vol.4 No.-

        검사기관에서 수행하고 있는 진단용엑스선장치의 정기검사에 대한 신뢰성 확보를 위하여 검사결과를 확인검사 이전에 평가할 수 있는 방법으로서 열형광선량계를 이용하여 진단용엑스선장치의 관저압 측정방법을 개발하였다. 열형광신량계 판독치의 재현성 향상을 위하여 적정한 엑스선 조사조건을 선정하였고, 소자보정계수 변동계수r~# 3% 이하인 열형광선량계만을 선별하였으며, 관전압 변화에 대한 영역평균판독치의 비의 직선성을 향상시키기 위하육 Cu필터를 사용하였다. 그 결과 판독치의 재현성이 29.8% 향상하였으며, 영역팡균판독치의 비 Ef/El, (ElxE4)/ E22, El/(E2-E4)는 관전압 변화에 대하여 직선성을 유지하고 있었다. E3/El은 엑스선관의 총여과 변화에 래하여 일정간격으로 이동하t s셔이 있어서 Sf/Tl을 이용하여 관전압을 측정하는 방법을 개발하였다. 이 방법은 60kv~110kv 범위 내에서의 평근오차범위는 -5.89%~+3.04없이었다. The escmation method of tube potential using thermoluminescent dosimeter was developed to screen the test 1·esult of aagnostic x-ray cnit performed by inspection compan:F.X-ray exposure condition having stable TL output and thermoluminescent doslmeters within 3%of coefficient of variance for dosimeter correction factor were selected to improve reproducibifityof TL output and copper filters were used for having better TL output ratio against tubepotential change. The reproducibiBity of TL output was improved 29.8% and TL output ratioES/Tl, (El x E4)/E2" and Et/(I:2-E4) were linear to tube potential change. TL output ration Ef/fl was used for the estimation method of tube potential because Ef/Elhad constant shift against total filtration variance of diagnostic x-;·ay erluipment. Mean error ofthis method for tube potential between 60kv and 110kv ranged from -5.89% to +3.04%.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼