오종식(Jong-Sik Oh),성병일(Beong-Il Sung),현용익(Yong-Ik Hyun) 한국유체기계학회 2003 유체기계 연구개발 발표회 논문집 Vol.- No.-
A high-efficiency turbo steam compressor has been successfully developed for the MVR desalination system, first one in Korea. The state-of-the-art design methods using real gas properties were applied to get all the aerodynamic design results. Bull and pinion gear trains, tilting-pad bearings and investment cast impellers were developed also to be integrated into the integral gear-driven turbo steam compressor. System tests show highly efficient performance.