http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
박기찬,김훈,신성선,신현길,김종태,정상화,박종락,Park, Gi Chan,Kim, Hun,Shin, Seong Seon,Shin, Hyun Keel,Kim, Jongtye,Jeong, Sanghwa,Park, Jong Rak 한국광학회 2012 한국광학회지 Vol.23 No.2
본 논문에서는 광생물 반응기의 조명 시스템으로 활용될 LED(Light-Emitting Diode)용 도광판의 광학설계 및 제작 결과에 대해 보고한다. 도광판 설계를 위해 광원, 반사필름, 도광판 패턴에 대한 모델링을 수행하였다. 특히, 도광판 패턴의 경우 램버시안 산란체(Lambertian Scatterer)로 모델링을 수행하였는데, 테스트용으로 제작된 도광판의 조도분포와 부합하는 모델 파라미터(반사율, 산란체의 폭)를 매칭 시뮬레이션을 통하여 추출하였다. 추출된 모델 파라미터를 사용하여 광학설계를 수행하였으며, CNC(Computer Numerical Control) 가공을 통해 도광판을 제작하였고, 평균조도와 조도균일도 등의 광학 특성을 측정하였다. We present results of optical design and fabrication of a light guiding plate (LGP) to be used as an illumination system for photobioreactors. Modeling of a light-emitting diode (LED) light source, a reflection film, and LGP patterns was performed. Especially, the LGP patterns were modeled as Lambertian scatterers. The modeling parameters (reflectance, scatterer width) were determined through matching simulations with the experimentally measured illuminance distribution for a test LGP. An LGP for an LED light source was designed with the extracted model parameters, and fabricated using a computerized numerical control machine. Optical characteristics including average illuminance and uniformity of illuminance distribution were measured for the fabricated LGP.
박기찬 ( Park Ki-chan ),최경숙 ( Choi Kyung-sook ) 한국농공학회 2019 한국농공학회논문집 Vol.61 No.3
This study developed selection criteria of small-scales reservoirs, having under 300,000㎥ storage capacity, for the Emergency Action Plan(EAP) establishment in order to reduce the disaster risks of the reservoir’s failures. Those reservoirs are out of ranges of Korean EAP establishment standard, but have potential risk of disasters as they have often failed by the recent extreme rainfall events and earthquakes, causing economical and life losses. The problem of reservoir aging is also one of the reasons of them. In this study, the developed selection criteria of small reservoirs for EAP establishment are storage capacity, embankment height, reservoir age, heavy rain factor and earthquake factor. These criteria were selected based on the review of the existing EAP establishment guidelines, analysis of the past dam failure cases, and the previous related studies. The quantification of these criteria were conducted for the practical applications in the fields, and applied to 67 previous failures in order to investigate the relation of each criteria with these failures. The earthquake factor found to be the highest relations followed by heavy rain factors, combination of earthquake and heavy rain factors, and reservoir age. The classification was made as observation and review groups for EAP establishments based on overlapping numbers of each criteria. This classifications applied to 354 reservoirs designated as having the potential disaster risk by MOIS, and showed 38.4% of observation and 11.9% of review groups. Anticipatory monitoring and regular inspection should be made by professional facility managers for the observation group, and necessity of EAP establishment should be assessed for the review group based on the downstream status and financial budget.