RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        고온기류중에 재분사된 연소기 후류의 수치해석

        김태한,권형정,Kim, Tae-Han,Gwon, Hyeong-Jeong 대한기계학회 1997 大韓機械學會論文集B Vol.21 No.7

        Combustion of gaseous fuel combustor in a high temperature vitiated air stream was studied with computer simulation. It is for application to afterburner of gas turbine engine which the exact mechanism is not yet clarified. As the jet velocity from fuel nozzle is very high and the geometry of combustor is three dimensional complex structure, many time and money are required to have good results. To consider this demerit, it is simplified to 2-dimensional and modified with the nozzle hole area to same area of annual status. As the thickness of annual is too thin, it is to divide with the many grids for reasonable results. Accordingly, new method which injected fuel mass, momentum and energy are added to source terms of each governing conservation equation as a source terms is introduced like as two phase analysis. Reaction rate is determined by taking into account the Arrhenius reaction based on a single step reaction mechanism. It is focused to temperature and product concentration distribution at each equivalence ratio of inlet hot product.

      • KCI우수등재

        다중이용시설 내 식생바이오필터 시스템의 PM<sub>10</sub>, PM<sub>2.5</sub> 저감효과 및 측정방법에 대한 연구

        김태한,최부헌,Kim, Tae-Han,Choi, Boo-Hun 한국조경학회 2020 韓國造景學會誌 Vol.48 No.5

        2019년 3월 미세먼지 비상저감조치가 일주일 동안 발령되면서, 미세먼지로 인한 국민의 불안감은 점차 가중되고 있다. 본 연구는 공기정화식물이 적용된 바이오필터의 다중이용시설 내 적용성 평가를 위해 입자상 오염원의 실내 연속방출환경을 조성하여 오염원 저감효과에 대한 측정방법을 제안하고, 시스템의 실내공기질 개선 여부를 확인할 수 있는 기초연구를 진행하였다. 강의실을 대상으로 춘절기에 모니터링 1시간 전 모기향을 오염원으로 배경농도를 조성한 후, 스케줄에 따라 2시간 관수, 1시간 송풍하여 미세먼지의 저감능을 확인하였으며, 바이오필터 2m 전방에 PM<sub>10</sub>, PM<sub>2.5</sub> 및 온습도 센서를 설치하고, 3개 송풍구 중 중앙에 풍속 프로브를 설치하여 시계열 모니터링을 수행하였다. 바이오필터에 구비된 총 3개소의 송풍구 평균 면풍속은 0.38±0.16 m/s로 댐퍼 면적이 제외된 송풍구별 면적 0.29m×0.65m을 적용한 총 공조풍량이 776.89±320.16㎥/h로 산출되었다. 시스템 가동으로 평균온도 21.5~22.3℃, 평균상대습도 63.79~73.6%를 유지하여, 선행연구의 다양한 조건별 온습도 범위에 부합하는 것으로 판단된다. 시스템 공조부 구동을 통해 급격하게 상대습도를 상승시키는 효과를 효율적으로 운용할 경우, 계절에 따른 실내 미세먼지 저감과 적정한 상대습도 확보도 가능할 것으로 판단된다. 미세먼지 농도는 바이오필터 시스템 가동 전의 모든 주기에서 상승 현상이 동일하게 집계되었으며, 시스템 가동 후 1주기 송풍구간(B-1, β=-3.83, β=-2.45)에서 미세먼지(PM<sub>10</sub>)는 최대 28.8% 수준인 560.3㎍/㎥, 초미세 먼지(PM<sub>2.5</sub>)는 최대 28.0% 수준인 350.0㎍/㎥까지 저감되었다. 이후 미세먼지(PM<sub>10</sub>, PM<sub>2.5</sub>)의 농도는 2주기 송풍구간 감소(B-2, β=-5.50, β=-3.30)로 각각 최대 32.6% 수준인 647.0㎍/㎥, 32.4% 수준인 401.3㎍/㎥까지 저감되었고, 3주기 송풍구간감소(B-3, β=5.48, β=-3.51)로 최대 30.8% 수준인 732.7㎍/㎥, 31.0% 수준인 459.3㎍/㎥까지 저감된 것으로 확인되었다. 본 연구는 식생 바이오필터의 다중이용시설 내 설치와 유관한 관련 표준 및 규정을 참조하여, 객관적인 성능평가환경의 구축 방안을 제시할 수 있었다. 이를 통해 일반 강의실 환경 내에 보다 객관화된 모니터링 인프라를 조성하여, 상대적으로 신뢰성 있는 데이터 확보가 가능했던 것으로 판단된다. With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM<sub>10</sub>, PM<sub>2.5</sub>, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM<sub>10</sub>) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM<sub>2.5</sub>) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM<sub>10</sub>, PM<sub>2.5</sub>) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

      • KCI등재

        풋콩 탈협기 개발을 위한 기초 연구 (II) - 탈협 및 선별 특성 -

        김태한,임학규,이정택,Kim T H.,Lim H. K.,Lee J. T. 한국농업기계학회 2004 바이오시스템공학 Vol.29 No.5

        Worldwide consumption of vegetable soybean has been increasing recently, but in the process of vegetable soybean production, threshing and separation work accounts fur about $80\%$ of overall labor. Therefore, developing of the vegetable soybean thresher is necessary to reduce the cost of labor. The main objective of this study is to acquire the basic in-formations for design of the vegetable soybean thresher which is suitable for domestic circumstances. We made the experimental system to investigate the threshing and separating performance at the several speeds of threshing cylinder and separating blower according to the kinds of threshing tooth. The result are as follows; Threshing performance of vegetable soybean thresher was shown as the best in case the threshing tooth made of rubber which has the 80 of Shore hardness was used at the circumference speed of cylinder of 5.8$\~$8.1m/s. Also separating cleaning performance of vegetable soybean thresher was shown as the best at more than 1,300 rpm of blower speed and $60\~80\%$ of opening ratio of suction port.

      • KCI등재
      • KCI등재
      • KCI등재

        조경기술기반 LID 시스템 적용을 통한 선릉·정릉 권역의 첨두유출량 분석

        김태한,최종희,Kim, Tae-Han,Choi, Jong-Hee 한국전통조경학회 2017 한국전통조경학회지 Vol.35 No.4

        본 연구는 조경기술기반 LID 시스템 적용에 따른 선릉 정릉 권역의 우수유출변화를 수문학적 관점에서 분석하였으며, 연구결과를 다음과 같이 정리할 수 있다. 첫째, 광화문 침수가 발생한 2011년 7월 27일 기준 최대순간강우량은 27일 10시에 기록된 183mm/hr로 시간당 최대강우량 57.5mm/hr에 비해 3배 이상의 강우강도가 10분간 집중된 것으로 확인되었다. 둘째, 토심기준 시나리오에서 담심 1,500mm의 경우 첨두유출량 제어가 가능하여 해당 조경기술기반 LID 시스템 적용 시 선릉 정릉 권역의 수해취약성을 개선할 수 있을 것으로 판단된다. 셋째, 담심 기준 시나리오에서 모든 토심 모형에서 첨두유출량 제어가 이루어지지 않았으나, 최초 우수유출을 토심 기준 시나리오에 비해 4시간 10분의 추가적인 지연효과를 기록하였다. 초기 우수유출저감에는 토심, 첨두유출량에는 담심이 상대적으로 중요한 지표로 해석되었다. 이를 통해 문화재 보호권역 내 경관친화적인 생태적 요소를 시스템화하여 적용할 경우 예상되는 수해방재효과를 이론적으로 확인할 수 있었다. This study analyzed hydrological changes of stormwater runoff of Seolleung Jeongneung zone according to the application of LID system based on landscape Architectural technology. The results are as follows. First, when flooding occurred in Gwanghwamun in July 27, 2011, the maximum instantaneous rainfall amount was 183 mm/hr recorded at 10:00 on 27th for 10 minutes, and it was confirmed that rainfall intensity more than three times as high as the maximum rainfall of 57.5 mm/hr. Second, it is possible to control peak flow rate in the case of 1,500mm of soil thickness, so that it is possible to improve the vulnerability of flood damage in Seolleung and Jeongneung zone when applying the LID system. Third, in the berm height scenario, peak flow rate control was not controled in all depth level models, but the first stormwater runoff was delayed by 4 hours and 10 minutes compared to the soil thickness scenario. It was interpreted as a relatively important indicator the soil thickness for the initial stromwater runoff reduction and the berm height for the peak runoff. Through this, the systematic adaptation of landscape-friendly ecological factors within the cultural property protection zone could theoretically confirm the effects of flood disaster prevention.

      • Smart Korea와 Smart Life를 위한 전파자원 이용정책 동향

        김태한,장재혁,성기훈,Kim, T.H.,Jahng, J.H.,Sung, K.H. 한국전자통신연구원 2011 전자통신동향분석 Vol.26 No.2

        최근 우리나라 사회의 각 분야에 걸쳐 Smart Korea를 구축하고자 하는 노력이 활발히 이루어지고 있다. 이는 각 개인뿐만 아니라 기기들도 지능적인 사고를 통해 서로 유기적으로 연결될 수 있는 체제를 의미하는데, 국가 전체적인 관점에서 Smart Korea가 구현되기 위해서는 각 개인의 관점에서의 똑똑한 삶인 Smart Life가 구현되어야 한다. 이러한 Smart Korea와 Smart Life의 구현을 위해서는 무선 통신을 위한 필수적 자원인 전파자원의 효율적인 활용이 기술적인 측면에서 뿐만 아니라 정책적인 측면에서도 중요하다. 본 고에서는 먼저 Smart Korea와 Smart Life의 개념을 살펴보고, 각각의 구현을 위한 전파자원의 이용정책 동향에 대해 기술하고자 한다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼