RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 켑스트럼 기반의 후두암 감별을 위한 채널보상

        김영국,김수미,김형순,왕수건,조철우,양병곤,Kim Young Kuk,Kim Su Mi,Kim Hyung Soon,Wang Soo-Geun,Jo Cheol-Woo,Yang Byung-Gon 대한음성학회 2004 말소리 Vol.50 No.-

        Automatic detection of laryngeal diseases by voice is attractive because of its non-intrusive nature. Cepstrum based approach to detect laryngeal cancer shows reliable performance even when the periodicity of voice signals is severely lost, but it has a drawback that it is not robust to channel mismatch due to different microphone characteristics. In this paper, to deal with mismatched training and test microphone conditions, we investigate channel compensation techniques such as Cepstral Mean Subtraction (CMS) and Pole Filtered CMS (PFCMS). According to our experiments, PFCMS yields better performance than CMS. By using PFCMS, we obtained 12% and 40% error reduction over baseline and CMS, respectively.

      • KCI등재

        순환주제에 의한 작곡전공 교수활동 수업사례물 분석: 김용환의 “Moving Figures”를 중심으로

        김영국 ( Young Guk Kim ) 한국예술교육학회 2015 예술교육연구 Vol.13 No.1

        본 논문의 목적은 대학교에서 작곡전공으로 교수활동을 하고 있는 본 연구자의 수업사례물이며, 본 연구자의 학생 김용환의 학습결과물인 ‘Moving Figures’를 순환주제(cyclic theme) 중심으로 분석하는 데 있다. 이를 위해 본 연구자는 이 작품의 각 부분에서 나타나는 독립적이며 개별적인 특징을 분석하였고, 전체의 곡을 하나로 묶어주는 수단으로써 작용한 순환주제에 관해 중점적으로 분석하였다. 이로써 대학 작곡전공학생의 수업, 특히 교수과정의 내용학 측면에서 도움을 주고자 한다. 본 논문의 주제어인 ‘순환주제’는 15세기의 정선율 미사, 16세기의 패러디 미사와 같은 작품에서 출발한 음악적 아이디어인데, 고전·낭만시대의 작곡가들이 소나타 형식과 같은 다악장의 악곡에서 하나 이상의 주제가 제 1악장뿐만 아니라 다른 악장에도 나타나게 하여 음악적 아이디어를 형식적인 틀 안에 가두기 위한 방법으로서도 이용되었다. 김용환의 ‘Moving Figures’는 이러한 고전적인 형식에서 아이디어를 빌려와 현대적으로 변용시켰다. 즉 고전적인 의미의 순환주제와는 다르게 <도입부-A-B-C-A``-coda>의 총 6개 부분으로 구성된 단악장 형식 내에서 순환주제의 변용, 발전을 모색했기에 고전적 의미로써의 순환주제 개념과는 상이하며 조금 더 진보된 양상을 띤다. The subject of this thesis is a case of the present class researchers and teaching activities studied composition at the university, and analyze the historical background and cyclic form in ``Moving Figures`` of Yong-hwan Kim, (1988~ ) my student. The purpose of this thesis is to study the structure with cyclic form, harmony and study elements such as timbre on Yong-Hwan Kim‘s ’Moving Figures`` appear in each part of an independent study is to focus on the subject appears as a means of circulation that bind specifically to one picece of the total and individual characteristics. Thus, the university student majoring in composition classes, and helping in the details, particularly on aspects of teaching process. Originally cyclic form is the musical ideas from works such as the cantus firmus mass, in the 16th century parody mass of the 15th century. Composers of the classical era composer and romantic era, were used also as a way of putting a musical ideas first movement to appear in more than one subject, as well as other movements in the same piece of music in the form of a multi-movement sonata form and framework. But ``Moving Figures`` is unlike the original meaning of cyclic form, <introduction-A-B-C-A``-coda> consists of a total of six section of, and since the transformation, the development of the cyclic form is made only in the movement type, and cyclic form as a classical concept with a different sense, may be seen to have a little more advanced aspects. The musical structure used in contemporary music appears dissolved and established patterns, but ``Moving Figures`` is borrowing ideas from the classical form and transformation into comtemporary is thought to be the work that needs to be thoroughly studied. and also can be considered in analysis for contemporary musical composition trends with music educational aspects.

      • KCI등재

        호흡연동방사선치료시 폐암과 간암환자의 병소 움직임 크기에 따른 선량분포 차이 분석

        김영국,임상욱,최지훈,마선영,정태식,노태익,Kim, Youngkuk,Lim, Sangwook,Choi, Ji Hoon,Ma, Sun Young,Jeung, Tae Sig,Ro, Tae Ik 한국의학물리학회 2014 의학물리 Vol.25 No.4

        호흡연동방사선치료(respiratory-gated radiation therapy)법을 적용한 세기조절방사선치료(intensity-modulated radiation therapy, IMRT) 시 환자의 호흡에 의한 장기 움직임 크기에 따른 계산된 선량분포와 측정된 선량분포의 차이를 분석하고자 한다. 치료를 완료한 폐암과 간암 환자 4명을 선택하였다. 한 환자당 5개의 조사면 총 20개의 조사면을 갠트리 각도를 모두 $0^{\circ}$로 변경하여 치료계획시스템(Eclipse Ver. 8.1, Varian Medical Systems, Inc., USA)으로 다시 계산하였다. 치료계획과 동일한 조건으로 각 IMRT 조사면을 2차원 이온전리함배열(MatriXX, IBA Dosimetry, Germany)을 자체 제작한 호흡모 플랫폼(respiratory simulating platform)위에 놓고 0, 1.0, 2.0, 및 3.0 cm 씩 호흡 움직임을 모사하여 일반적으로 치료에 사용되는 연동창 범위인 30~70% 위상을 선택하여 호흡연동방사선치료법으로 조사하여 선량분포를 측하였다. 계산된 선량분포와 측정된 선량분포의 2차원적 비교를 위해 소프트웨어(Omni-pro I'mRT, IBA Dosimetry, Germany)를 이용하여 3 mm/3%의 기준으로 감마 지표(gamma index)로 비교하였다. 움직임이 없을 때 감마 지표의 합격률이 평균 98.63% 였으며, 움직임을 1.0, 2.0, 3.0 cm으로 모사할 경우 합격률이 각각 평균 98.59%, 97.82%, 95.84%로 낮아졌다. 따라서 실제 환자에 대해 호흡연동방사선치료법을 적용한 세기조절방사선치료 시 병소의 움직임이 2 cm가 넘을 경우 ITV (internal target volume) 여유분을 크게 설정하거나 연동창을 좁게 선택하여야한다. To see the discrepancies between the calculated and the delivered dose distribution of IMRT fields for respiratory-induced moving target according to the motion ranges. Four IMRT plans in which there are five fields, for lung and liver patients were selected. The gantry angles were set to $0^{\circ}$ for every field and recalculated using TPS (Eclipse Ver 8.1, Varian Medical Systems, Inc., USA). The ion-chamber array detector (MatriXX, IBA Dosimetry, Germany) was placed on the respiratory simulating platform and made it to move with ranges of 1, 2, and 3 cm, respectively. The IMRT fields were delivered to the detector with 30~70% gating windows. The comparison was performed by gamma index with tolerance of 3 mm and 3%. The average pass rate was 98.63% when there's no motion. When 1.0, 2.0, 3.0 cm motion ranges were simulated, the average pass rate were 98.59%, 97.82%, and 95.84%, respectively. Therefore, ITV margin should be increased or gating windows should be decreased for targets with large motion ranges.

      • KCI등재

        강력한 임의진동 하에서 PBGA 패키지의 실험적 신뢰성 검증

        김영국,황도순,Kim, Yeong K.,Hwang, Dosoon 한국마이크로전자및패키징학회 2013 마이크로전자 및 패키징학회지 Vol.20 No.3

        Plastic ball grid array (PBGA)에 대한 강력한 임의 진동에서의 신뢰성을 실험적으로 검증하였다. 실험시편을 만들기 위해 데이지 체인이 형성된 PCB에 칩을 실장시킨 후 그중 절반은 underfill 공정을 거쳤다. 임의 진동 프로파일은 인공위성 전자장비의 신뢰성 검증에서 사용되는 두 종류의 진동 수준, 즉 판정시험 (acceptance level) 및 합격시험(qualification level)을 사용하였으며 각각의 power spectrum density는 22.7 Grms와 32.1 Grms였다. 실험후 underfill과 관계없이 모든 샘플에서 솔더의 균열이 발생되지 않았으며, 차후 항공 및 우주용 전자장비를 대치할 수 있는 패키징 구조의 가능성을 보여 줬다. Experimental analyses on the solder joint reliability of plastic ball grid array under harsh random vibration were presented. The chips were assembled on the daisy chained circuit boards for the test samples preparation, half of which were processed for underfill to investigate the underfill effects on the solder failures. Acceptance and qualification levels were applied for the solder failure tests, and the overall controlled RMS of the power spectrum densities of the steps were 22.7 Grms and 32.1 Grms, respectively. It was found that the samples survived without any solder failure during the tests, demonstrating the robustness of the packaging structure for potential avionics and space applications.

      • KCI등재

        센서 패키지용 고분자 접착제의 열화 거동 분석

        김영국,이윤선,Kim, Yeong K.,Lee, Yoon-Sun 한국마이크로전자및패키징학회 2017 마이크로전자 및 패키징학회지 Vol.24 No.1

        열중량 분석(Thermogravimetry)을 이용하여 열화시간 경과에 따른 접착 소재의 열에 대한 열화 특성을 분석하였다. 실험에는 여섯 가지의 온도 승온률에서 측정된 데이터를 이용하여 열화에 따른 동적 반응을 분석하였다. 이 데이터를 바탕으로 아레니우스 방정식을 이용하여 활성 에너지와 비례 상수 등 모델에 필요한 계수를 계산하였다. 또한 열화거동을 예측하는 방정식으로는 무게 감소에 따른 간단한 n차 방정식을 이용하였다. 구해진 예측 모델은 실험 데이터와 비교하여 검증하였다. 계산 결과 각 승온률에 따라 활성화 에너지의 크기가 다름에 따라 평균값을 사용하여 계산한 결과는 낮은 승온률인 경우에는 잘 예측하였지만 높은 승온률인 경우에는 측정값과 차이를 보였다. 이와 같은 문제를 해결하기 위해 지수함수 급수를 이용한 새로운 모델링 방법이 처음 시도되었으며 예측된 결과는 승온률에 관계없이 실험 데이터와 잘 일치하였다. An analysis of thermal degradation of epoxy based adhesive performed by thermogravimetry tests are presented in this study. Six different heating rates were employed for the weight change measurements. Based on the data, an Arrhenius type modeling equation was developed by calculating activation energies and proportional constants, and $n^{th}$ polynomial function was adopted to predict the weight change rates. The prediction results by the modeling was compared with the data using the average activation energy. It was found that the activation energy at the each heating rate was not same due to the different degradation kinetics, especially at the high heating rate. To overcome this pitfall, a new approach using exponential function series was introduced and employed. The calculation results showed very good agreements with the test data regardless of the heating rates.

      • KCI등재

        자동차용 에어백 센서의 패키징 방법에 따른 신호 전달 해석

        김영국,강현진,김준기,Kim, Yeong K.,Kang, Hyun Jin,Kim, Joon Ki 한국마이크로전자및패키징학회 2015 마이크로전자 및 패키징학회지 Vol.22 No.4

        In this study, a new airbag sensor packaging technique of directly attachment by adhesive to the automobile frame is introduced. To assess the feasibility for the packaging, a test instrument was manufactured to examine the impact sensibility by drop tests. The conventional sensor module attached mechanically by bolts with plastic housing and the new sensor packaging were installed to aluminum channel, and the results were compared with each other. Numerical analysis was also performed to investigate the signal characteristics created by the sensors. The preliminary results showed that the pattern of the MEMS sensor signal was strongly dependent on the structural behavior of the frame where the sensors were installed, which indicated the complexity of the packaging design for proper airbag deployments. 이 연구에서는 자동차용 에어백 작동에 쓰이는 가속 센서에 대해, 그 실장 방법에 따른 신호 전달 차이를 해석하였다. 실장 방법은 기존에 쓰이는 하우징을 사용한 모듈 형태와, 센서를 직접 자동차의 구조물에 접합재를 사용하여 부착하는 두 가지 방법을 고려하였다. 신호 전달을 분석하기 위하여, 충격 실험 장비가 구축되었고, ㄷ자형 알루미늄 채널을 이용하여 그 표면에 기존의 모듈 채결 방법과 센서를 직접 부착하는 방법을 사용하여 시편을 제작하여, 충돌 실험 후 측정된 파형을 비교하여 그 차이를 분석하였다. 또한 유한요소법을 이용하여 충격 실험을 모사하였고, 계산 결과를 실험 데이터와 비교하였다. 그 결과, 기존의 모듈형태의 부착 방법보다, 이 연구에서 제시된 접착제에 의해 직접 부착된 센서가 측정한 신호가 상대적으로 잡음없이 깨끗하고 강한 것을 알 수 있었으며, 또한 에어백 센서와 같은 MEMS 센서는 부착 방법에 따라 주변의 간섭 효과에 의해 그 성능이 크게 변하는 것을 알 수 있었다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼