RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSSCIEKCI등재

        모야모야병에서 염기성 섬모 세포 성장 인자의 역할

        김동석,최중언,김세혁,양국희,김현숙,Kim, Dong-Seok,Choi, Joong-Uhn,Kim, Se-Hyuk,Yang, Kook-Hee,Kim, Hyeun-Sook 대한신경외과학회 2001 Journal of Korean neurosurgical society Vol.30 No.1

        Objectives and Importance : The present study investigated the levels of basic fibroblast growth factor(bFGF) in the CSF of patients with moyamoya disease and its clinical significance. Methods : The levels of bFGF in CSF, taken from 26 hemispheres of 14 moyamoya patients and 20 patients without vascular anomaly(control group), were measured by an enzyme-linked immunosorbent assay. We analyzed the correlation between the level of bFGF and the clinical factors such as age, onset pattern, development of neovascularization, and cerebral circulation. Results : The CSF of moyamoya patients contained a high concentration of bFGF to a significant extent. The bFGF level was apparently elevated in the patients in whom neovascularization from indirect revascularization, such as modified encephalo-duro-arterio-synangiosis(EDAS) was well developed. A linear correlation between the values of bFGF and clinical progression was noted. Conclusions : The elevation of bFGF in moyamoya disease seems to be specific. Clinically, the bFGF level may be considered a useful indicator to predict the efficacy of indirect revascularization.

      • 3D OSEM 재구성 법에서 반복연산(Iteration) 횟수와 부분집합(Subset) 개수 변경에 따른 영상의 질 평가

        김동석,김성환,심동오,유희재,Kim, Dong-Seok,Kim, Seong-Hwan,Shim, Dong-Oh,Yoo, Hee-Jae 대한핵의학기술학회 2011 핵의학 기술 Vol.15 No.1

        Purpose: Presently in the nuclear medicine field, the high-speed image reconstruction algorithm like the OSEM algorithm is widely used as the alternative of the filtered back projection method due to the rapid development and application of the digital computer. There is no to relate and if it applies the optimal parameter be clearly determined. In this research, the quality change of the Jaszczak phantom experiment and brain SPECT patient data according to the iteration times and subset number change try to be been put through and analyzed in 3D OSEM reconstruction method of applying 3D beam modeling. Materials and Methods: Patient data from August, 2010 studied and analyzed against 5 patients implementing the brain SPECT until september, 2010 in the nuclear medicine department of ASAN medical center. The phantom image used the mixed Jaszczak phantom equally and obtained the water and 99mTc (500 MBq) in the dual head gamma camera Symbia T2 of Siemens. When reconstructing each image altogether with patient data and phantom data, we changed iteration number as 1, 4, 8, 12, 24 and 30 times and subset number as 2, 4, 8, 16 and 32 times. We reconstructed in reconstructed each image, the variation coefficient for guessing about noise of images and image contrast, FWHM were produced and compared. Results: In patients and phantom experiment data, a contrast and spatial resolution of an image showed the tendency to increase linearly altogether according to the increment of the iteration times and subset number but the variation coefficient did not show the tendency to be improved according to the increase of two parameters. In the comparison according to the scan time, the image contrast and FWHM showed altogether the result of being linearly improved according to the iteration times and subset number increase in projection per 10, 20 and 30 second image but the variation coefficient did not show the tendency to be improved. Conclusion: The linear relationship of the image contrast improved in 3D OSEM reconstruction method image of applying 3D beam modeling through this experiment like the existing 1D and 2D OSEM reconfiguration method according to the iteration times and subset number increase could be confirmed. However, this is simple phantom experiment and the result of obtaining by the some patients limited range and the various variables can be existed. So for generalizing this based on this results of this experiment, there is the excessiveness and the evaluation about 3D OSEM reconfiguration method should be additionally made through experiments after this. 현재 핵의학 분야에서는 디지털 컴퓨터의 급속한 발전 및 응용으로 인해 FBP 법의 대용으로 OSEM 알고리즘과 같은 고속 영상 재구성 알고리즘이 널리 이용되고 있다. 그 동안 여러 연구에서 파라미터 변경에 따른 OSEM 재구성 영상 질 변화에 대한 평가가 이루어져 왔으나, 어떠한 파라미터를 적용할 지에 관해서는 명확하게 정해진 것은 없다. 본 연구에서는 3D beam modeling을 적용한 3D OSEM 재구성 법에서 iteration 횟수와 subset 개수 변경에 따른 영상의 질 변화를 팬텀 실험과 환자 데이터을 통해 확인하고자 한다. 환자 데이터는 2010년 8월부터 9월까지 본원 핵의학과에서 Brain SPECT를 시행한 환자 5명을 대상으로 연구 분석하였다. 영상은 물과 $^{99m}Tc$ (500 MBq)을 균등하게 혼합한 Jaszczak 팬텀을 이용하여 Siemens사의 이중 헤드 감마 카메라 Symbia T2에서 획득하였다. 환자 데이터는 영상 재구성 시 환자 데이터와 팬텀 데이터 모두 iteration 횟수는 1, 4, 8, 12, 24, 48회, subset 개수는 2, 4, 8, 16, 32개로 변화를 주며 각각의 영상을 재구성하였다. 재구성된 각각의 영상에서 대조도와 영상의 잡음 정도를 가늠하기 위한 변이계수, FWHM을 산출하여 비교하였다. 팬텀 데이터와 환자 데이터에서 영상의 대조도와 공간해상력은 iteration 횟수와 subset 개수의 증가에 따라 모두 선형적으로 증가하는 경향을 나타냈으나 변이계수는 두 파라미터의 증가에 따라 향상되는 경향을 보이지 않았다. Projection 시간에 따른 비교에서도 Projection 당 10초, 20초, 30초 영상에서 모두 영상 대조도와 FWHM은 iteration 횟수와 subset 개수 증가에 따라 선형적으로 향상되는 결과를 나타냈으나 변이계수는 향상되는 경향을 보이지 않았다. 본 실험을 통해 3D beam modeling을 적용한 3D OSEM 재구성 법 영상에서도 기존의 1D와 2D OSEM 재구성 법과 같이 iteration 횟수와 부분집합 개수 증가에 따라 향상하는 영상 대조도의 선형적 관계를 확인할 수 있었다. 하지만 이는 단순한 팬텀 실험과 일부 환자 데이터 만으로 얻은 결과이고, 실제 임상에서는 보다 구조적으로 복잡한 대상과 다양한 변수들이 존재 가능하기 때문에 본 실험의 데이터만을 바탕으로 이를 일반화하기에는 무리가 있으며 차후 실험들을 통해 3D OSEM 재구성 법에 대한 평가가 추가로 이루어져야 할 것이다.

      • 전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과

        김동석,박장원,최재민,심동오,김호성,이영희,Kim, Dong Seok,Park, Jang Won,Choi, Jae Min,Shim, Dong Oh,Kim, Ho Seong,Lee, Yeong Hee 대한핵의학기술학회 2017 핵의학 기술 Vol.21 No.1

        전신 뼈 스캔은 핵의학에서 가장 많은 비중을 차지하는 검사 중 하나이다. 기본적으로 전면상과 후면상을 동시에 획득하는데, 때때로 전면상과 후면상만으로는 병소를 분간하기 어려울 때가 있다. 이러한 경우 SPECT/CT나 추가 정적 영상을 통한 병소의 정확한 위치 확인이 중요하며, 추가 촬영 여부에 대한 최초 판단은 주로 방사선사에 의해 이루어진다. 이에 본원에서는 방사선사의 업무 능력 함양을 위한 다양한 개선활동이 이루어져 왔고, 본 연구에서는 방사선사의 교육 및 표준화된 업무 프로세스 적용이 전신 뼈 스캔 오류 감소에 어떠한 영향을 미치는지 확인하고자 한다. 새로운 프로세스 적용을 위해 몇 가지 시스템이 순차적으로 도입되었다. 첫 번째는 의국 교육 및 테스트의 시행, 두 번째는 추가 촬영이 예상되는 환자를 분류하여 촬영 전에 방사선사가 미리 확인할 수 있는 사전 여과 시스템 도입, 마지막으로 판독의가 방사선사에게 직접 촬영 영상에 대해 피드백 할 수 있는 NMQA라는 커뮤니케이션 시스템을 적용하였다. 결과 확인을 위해 2014년 1월부터 2016년 12월까지 서울아산병원 핵의학과를 내원한 전신 뼈 스캔 환자를 대상으로 조사하였다. 조사 기간 동안 전체 전신 뼈 스캔 대비 NMQA가 전송된 검사 건수를 백분율로 산출하였다. 연간 발생량은 2014년 141건, 2015년 88건, 2016년 86건으로 집계되었고 NMQA 발생률은 2014년 0.88%, 2015년 0.53%, 2016년 0.45%로 감소하였다. 새로운 프로세스가 적용된 2014년 이후 NMQA 발생률이 감소하는 경향을 보였다. 다만 통계적으로 유용성을 확인하기까지는 데이터가 부족하여 향후에도 지속적인 데이터 축적이 필요할 것으로 생각한다. 본 연구를 통해 전신 뼈 스캔 영상 질 향상을 위해 표준화된 업무와 교육의 필요성을 확인하였고 향후에도 지속적인 연구와 관심으로 업데이트가 필요하다고 사료된다. Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.

      • KCI등재

        0.25 ㎛ GaAs pHEMT 공정을 이용한 X-대역 코아-칩의 설계

        김동석,이창대,이동현,염경환,Kim, Dong-Seok,Lee, Chang-Dae,Lee, Dong-Hyun,Yeom, Kyung-Whan 한국전자파학회 2018 한국전자파학회논문지 Vol.29 No.5

        We herein present the design and fabrication of a Rx core chip operating in the X-band (10.5~13 GHz) using Win's commercial $0.25-{\mu}m$ GaAs pHEMT process technology. The X-band core chip comprises a low-noise amplifier, a four-bit phase shifter, and a serial-to-parallel data converter. The size is $1.75mm{\times}1.75mm$, which is the state-of-the-art size. The gain and noise figure are more than 10 dB but less than 2 dB, and both the input and output return losses are less than 10 dB. The RMS phase error is less than $5^{\circ}$, and the P1dB is 2 dBm at 12.5 GHz, the performance of which is equivalent to other GaAs core chips. The fabricated core chip was packaged in a QFN package type with a size of $3mm{\times}3mm$ for the convenience of assembly. We confirmed that the performance of the packaged core chip was almost the same as that of the chip itself. 본 논문에서는 Win 사의 상용 $0.25{\mu}m$ GaAs pHEMT 공정 기술을 이용하여 X-대역(10.5~13 GHz)에서 동작하는 수신부 코아-칩의 설계 및 제작을 보였다. X-대역 코아-칩은 저잡음증폭기, 4-비트 위상천이기, 직렬-병렬 컨버터(SPC: Serial to parallel data converter)로 구성되며, 크기는 $1.75{\times}1.75mm^2$로 지금까지 보고된 코아-칩 중 가장 소형의 크기를 갖는다. 사용 주파수 대역에서 이득 및 잡음지수는 각각 10 dB 이상, 2 dB 미만, 입출력 반사손실은 10 dB 미만이다. RMS 위상 오차는 12.5 GHz에서 $5^{\circ}$ 미만, P1dB는 2 dBm으로 타 코아-칩과 대등한 성능을 갖는다. 제작된 코아칩은 조립의 편의를 제공하기 위해 $3{\times}3mm^2$ 크기를 갖는 QFN 패키지로 패키지되었으며, 패키지된 코아-칩의 성능은 칩-자체의 성능과 거의 같음을 확인하였다.

      • KCI등재

        분산객체그룹프레임워크 기반 모바일 협업 환경 및 적용에 관한 연구

        김동석,정창원,주수종,Kim, Dong-Seok,Jeong, Chang-Won,Joo, Su-Chong 한국정보처리학회 2006 정보처리학회논문지D Vol.13 No.6

        본 논문에서는 모바일 디바이스들 간에 협업을 제공할 수 있는 프레임워크를 제시하고, 그를 기반으로 헬스케어 응용 서비스를 구현하였다. 제안한 프레임워크는 3가지의 구성요소인 센서와 모바일 디바이스 그룹, 홈 서버의 상호작용을 위한 인터페이스를 정의하고, 고정형과 이동형 디바이스들(PDAs)을 이용한 협업 환경을 제시한다 이동형 디바이스들 간의 정보의 교환은 Push와 Pull 방식을 사용하였으며, 다수의 센서로부터 수집된 정보는 모바일 디바이스들과 홈 서버에 의해 공유 또는 교환한다. 우리의 협업 프레임워크는 이전 연구에서 개발된 분산객체그룹프레임워크(DOGF)에서 구현된 객체그룹관리, 정보저장, 접근제어에 따른 허가와 승인기능들을 응용 인터페이스를 통해 제공받게 된다. 헬스케어 서비스의 중요한 부분인 보안을 지원하기 위해 보안정보를 구분하였고, 정보의 이용 권한을 DOGF의 보안 객체를 통하여 인증할 수 있는 절차를 제시하였다. 또한, 사용자의 프로필 정보를 제공함으로써 사용자에 따른 서비스 객체에 대한 권한 검사를 하였다. 각 모바일 디바이스와 홈 서버에 구현된 컴포넌트는 TMO 스킴을 적용하였으며, 이들 분산된 컴포넌트들 간의 통신을 지원하기 위해 분산 실시간 미들웨어인 TMOSM을 사용하였다. 끝으로 협업 프레임워크 상에서 제시한 헬스케어 응용 시나리오의 수행성을 GUI를 통해 보였다. In this paper, we suggested a mobile collaboration framework for supporting mobile services among mobile devices, and designed and implemented on this environment. The suggested framework has three elements; groups of sensors and mobile devices(Fixed and Moving-typed PDAs) and a home server. We designed interfaces for interactions with each other in collaboration environment with three elements described above. The information collected by sensors can be share and exchanged by mobile devices or a home server in accordance with Push and Pull methods. This framework is based on the distributed object group framework(DOGF) we implemented before. Therefore the DOGF provides functions of object group management, storing information and security services to our mobile collaboration framework via application interfaces defined. The information collected by sensors is arranged according to user's security 'demands. And user profile information is used for checking authority of each service object. Each component for executing functions of mobile devices and a home server is implemented by TMO scheme. And we used the TMOSM for interactions between distributed components. Finally, we showed via GUI the executablity of a given healthcare application scenario on our mobile collaboration framework.

      • 무선인터넷 환경에서 자기주도학습 모바일 콘텐츠 설계

        김동석,신판섭,Kim, Dong-Seok,Shin, Pan-Seop 한국컴퓨터산업학회 2007 컴퓨터産業敎育學會論文誌 Vol.8 No.1

        본 연구에서는 무선인터넷의 교육적 활용을 위해 국내 무선인터넷 기술현황과 이용실태에 알아보고 관련연구 및 사례분석을 통해, 이를 바탕으로 현 시점에서 적용 가능한 '행렬 OX 퀴즈'를 설계 및 구현 하였다. 본 시스템의 주요 특징은 다음과 같다. 첫째, 기존의 유선인터넷의 시간적, 공간적 제약을 탈피하여 무선인터넷 시대에 맞는 교육콘텐츠를 제시함으로써 교육적 효과를 거두고자 하였다. 둘째, 현재의 무선인터넷 사용 환경과 기술을 충분히 고려하여 휴대폰을 무선 인터넷 단말기로 선택하였고, 현재 가입자 수가 가장 많은 SK텔레콤의 WAP방식 Markup언어를 지원하여 사용자의 편의성을 증진시켰다. 셋째, 무선인터넷 활용수업을 통해 학생의 자기주도 학습 능력을 신장시킬 수 있다. 특히, 무선인터넷 활용 수업을 통해 자신의 학습에 대한 책임감을 높이고 직면한 학습 문제를 해결하는 데 필요한 기술과 능력을 키울 수 있다. 본 연구에서 구현된 교육콘텐츠는 무선인터넷이 보편화되면 충분한 교육적 효과가 기대된다. In this study, current status of technology and realities of usage on wireless Internet for educational applications were examined, and based on related studies and case analysis, 'Matrix OX Quiz' that can be applied at present time was designed and built. Main characteristics of this system are as below: Firstly, an attempt was made to achieve educational effect by offering educational contents that are suitable for wireless Internet era, breaking away form limitations on time and space with previous wired Internet. Secondly, mobile phone was selected as the wireless Internet terminal considering the current wireless Internet usage environment and technology, and improved convenience by supporting WAP form Markup language used by SK telecommunications with the most enrollment at present. Thirdly, self-directed learning capability of students can be improved through lessons utilizing wireless Internet. Especially, responsibilities for teaming can be increased through lessons utilizing wireless Internet, and abilities needed for solving immediate problems can be developed. Therefore, the educational contents built in this study should have sufficient educational effects if wireless Internet becomes widely spread and most students can easily use it in near future.

      • KCI등재

        서로 다른 산포를 허용하는 이변량 영과잉 음이항 회귀모형

        김동석,정슬기,이동희,Kim, Dong-Seok,Jeong, Seul-Gi,Lee, Dong-Hee 한국통계학회 2011 Communications for statistical applications and me Vol.18 No.5

        본 연구에서는 두 반응 변수에 서로 다른 산포를 허용하는 새로운 이변량 영과잉 음이항 회귀모형을 제안하고, Deb과 Trivedi (1997)에 나타난 헬스케어 자료를 이용하여 두 반응변수가 갖는 서로 다른 산포도를 무시한 Wang (2003)이 제안한 이변량 영과잉 음이항 회귀모형과의 효율성을 로그우도와 AIC의 관점에서 비교 하였다. 모형적합결과, 본 연구에서 제안한 모형이 모형선택기준 관점에서 기존모형에 비하여 월등히 우수한 결과를 보여주었다. We propose a new bivariate zero-inflated negative binomial regression model to allow heterogeneous dispersions. To show the performance of our proposed model, Health Care data in Deb and Trivedi (1997) are used to compare it with the other bivariate zero-inflated negative binomial model proposed by Wang (2003) that has a common dispersion between the two response variables. This empirical study shows better results from the views of log-likelihood and AIC.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼