RISS 활용도 분석
일본/중국/유럽자료
최신/인기 학술자료
해외논문구매대행(E-DDS)
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
『다케토리 모노가타리』의 이중적 서술 구조와 연결 매개체
민병훈(Min, Byung-Hoon) 대한일어일문학회 2018 일어일문학 Vol.79 No.-
“Taketori Monogatari” introduces various stories such as ‘an eccentric person"s birth story', ‘wife-obtaining fight story', ‘derivation story', and ‘fairy robe-related story'. Just as shown in the names, they could be divided into stories with realistic materials and stories with unrealistic materials. However, in the parts like ‘development and growth of Kaguyahime' and ‘proposal and ascension of the emperor' with the unrealistic materials, the narrators and characters do not show any self-awareness of the unreality as the story develops under the realistic sense. On the other hand, in the part like ‘five young nobles proposal' which intentionally mixes the unrealistic materials in the real world, the clear perception of the unreality is built on. In order to combine the double-narrative structure stories for a Monogatari work, the author uses several connecting links such as ‘marriage', ‘treasure in imagination' shown in the legend, and ‘rumor'. And here, an ‘old man' plays a role of mediator in tying stories into one. “Taketori Monogatari” has become an ancestor of Japanese novels by deriving diverse-types of novels. However, the novels that realistically handle unrealistic materials gradually decline, and only Monogatari based on the stories with realistic materials is inherited. “Taketori Monogatari” could be evaluated as a work playing the role of driving force in the transitional period from the unrealistic myths or stories to the Japanese-style reality novels, Monogatari literature.
민병훈 ( Byung Hoon Min ), 김재준 ( Jae J. Kim ) 대한내과학회 2009 대한내과학회지 Vol.77 No.2
Noncardiac chest pain (NCCP) is defined as recurring angina-like retrosternal chest pain of noncardiac origin. Although gastro-esophageal reflux disease (GERD) is recognized as the most frequent cause of this disorder, the pathophysiology remains to be elucidated fully. In Western countries, upper endoscopy has limited value in the differential diagnosis of NCCP because most of the mucosal findings detected are consistent with GERD. By contrast, in Korea the prevalence of gastric or duodenal ulcers in NCCP patients ranges from 17.9 to 20.7%. Considering this high prevalence and the different treatment strategies for GERD and peptic ulcer disease, upper endoscopy should be included in the initial work-up for NCCP in Korean patients. (Korean J Med 77:184-186, 2009)
서울메트로 접지시스템의 경년변화에 따른 개선 접지 기준
민병훈(Byung-Hoon Min), 김균식(Gyunl-Sig Kim), 정용기(Young-Ki Chung) 한국철도학회 2006 한국철도학회논문집 Vol.9 No.4
Since Seoulmetro built the first line of electric railway at seoul 1974, the passengers of railway have been increased rapidly, and electric railway requires more electric power for the greater capacity of transport. It is important that we prevent the accidents related with the subway, because all systems of subway are constructed in artificial underground structure. Since the previous versions of the earth system were built to meet the old standards of the electric facility for the lightning, some accidents related with the DC earth fault are causing secondary damages to the electric equipments. So, the old grounding system must be improved, and new standards of grounding system are required. We compare the grounding systems of the domestic railway corporations and the accidents that are related with the grounding systems. And we give ideas to improve the grounding systems and present standards which are suitable to electric railway.
閔病薰(Byung-Hoon Min), 張禹鎭(Woo-Jin Jang), 高寅錫(In-Suk Ko) 대한전기학회 2006 전기학회논문지 B Vol.55 No.8
Even the case DC circuit Breaker have good quality for interruption of high current like heavy load current, short-circuit current, the verification for small current breaking capability of circuit breaker should be performed. It comes from the reason DC small current breaking failure can be lead to break out second heavy fault condition and in the long run substation shutdown. In this paper, we can find the characteristics of DC small current and international test standard discription about small current breaking and one of the proper solution to get over it.