http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
조경현,신동구,백석환,김재룡 생화학분자생물학회 2009 Experimental and molecular medicine Vol.41 No.2
Several parameters and risk factors were compared between Korean male myocardial infarction (MI) patients (n = 10) and angina pectoris (AP) patients (n = 17) to search unique biomarkers for myocardial infarction (MI) in lipoprotein level. Individual serum and lipoprotein fractions (VLDL, LDL, HDL2, HDL3) were isolated and analyzed by lipid and protein determination and enzyme assay. The MI group was found to have a 25 and 30% higher serum cholesterol and triacylglycerol (TG) level than the AP group, respectively, however, their body mass index (BMI), LDL-cholesterol (C), HDL-C, and glucose levels fell within the normal range. MI patients were found to have an approximately two-fold higher level of serum IL-6 and an 18% lower serum apoA-I level than that of the AP group. LDL and HDL2 fraction of the MI group were more enriched with TG than those of AP group. The increased TG was correlated well with the increased level of apoC-III in the same fraction. Cholesteryl ester transfer protein (CETP) activity and protein level were greatly increased in MI patients in the LDL and HDL3 fractions. MI patients showed more severely oxidized LDL fraction than patients in the AP group, as well as the weakest antioxidant ability of serum. Conclusively, MI patients were found to have unique serum and lipoprotein characteristics including increased IL-6 and TG in serum, with CETP and apoC-III in the LDL and HDL fractions, as well as severely impaired antioxidant ability of HDL.
유치의 치아우식증 확인을 위한 정량형광분석(QLF) 검사법의 우식탐지능력 평가
조경현,강정민,정회인,이태양,송제선 대한소아치과학회 2022 大韓小兒齒科學會誌 Vol.49 No.1
본 연구의 목적은 유치의 치아우식증 검사를 위한 정량형광분석(quantitative light-induced fluorescence, QLF) 기술의 유효성을 평가하고, 우식병소의 부피와 QLF 분석결과 사이의 상관관계를 확인하는 것이다. 치아우식증 검사를 위해 53개의 교합면 및 72개의 인접면을 포함한 총 125개의 유구치 치면을 휴대용 QLF 장비를 이용해 조사하여 유구치의 치아우식증을 확인하였다. 또한 치아우식증을 분류하고 우식병소의 부피를 계산하기 위해 micro-CT 방사선 검사를 시행하였다. 상대적으로 낮은 수치를 보였던 인접면 우식에대한 ΔR average 결과를 제외하면, QLF 분석결과는 유치의 치아우식증 진단에 대해 충분한 수준의 정확성과 신뢰도를 보였다(민감도0.75 - 0.94, 특이도 0.82 - 0.95, AUROC 0.88 - 0.98). Spearman 상관분석 결과에서는 ΔF average 및 QS-Index와 우식병소 부피 사이에 통계적으로 유의한 높은 상관성을 확인할 수 있었다(r = 0.805 - 0.832, p < 0.001). QLF 기술을 이용한 치아우식증 검사는 어린이의치아우식증 진단에 있어 방사선 노출에 대한 걱정 없이 안전하게 사용 가능하고, 신뢰할 만한 방법이 될 수 있을 것이다.
헬륨 마이크로파 플라즈마 토치의 개발과 특성에 관한 연구
조경현,박용남,Jo, Kyung Hyun,Pak, Yong Nam 대한화학회 2000 대한화학회지 Vol.44 No.6
MPT, which has been developed recently, is very tolerant to aqueous samples. Several types of MPT have been investigated and is found that the double concentric tube could sustain a stable plasma at a low plasma gas flow rate. However, the tip of torch is easily ruined. Triple concentric torch has shown the best stability and the plasma shape, much like that of ICP, especially when the central channel is quartz. The plasma is exposed and mixed with air as is suggested from the background spectrum, which leads to quenching of He MPT. Sensitivity of helium MPT equipped with a membrane desolvator has shown 10 times lower than that of Argon MPT for most of elements except for the ones with relatively high excitation energy. He MPT requires small plasma flow rate (about 1.6 L/min), stable and simple to use. Excitational temperature and electron number density measured are 4950 K and 3.28 ${\times}$ $10^{14}cm^{-3}$, respectively. MPT는 최근에 개발된 마이크로파 플라즈마로서 수용매에 강하다. 여러 가지의 변형된 형태의 MPT를 개발하여 구조에 따른 플라즈마의 방전되는 형태를 조사한 결과 이중관 토치는 플라즈마 기체를 적게 소모하며 쉽게 플라즈마가 형성되었으나 토치의 끝이 높은 온도에 견디지 못하고 쉽게 상했다. ICP토치와 같은 형태의 삼중관 토치에 석영관을 중심관으로 사용할 때 가장 안정되고 대칭적인 플라즈마를 형성할 수 있었다. 바탕선을 조사해 본 결과 He MPT는 대기 중으로 돌출되어 대기와 많이 혼합되고 질소에 의해 quenching되는 것으로 보여진다. Membrane desolvator를 탈용매화 장치로 사용하여 헬륨 MPT의 감도를 조사해 본 결과 아르곤 MPT와 비교할 때 대부분의 원소에 대해 검출한계가 10배 이상 높았다. 그러나 여기 에너지가 높은 원소는 비교적 효율적으로 검출할 수 있었다. 헬륨 마이크로파 플라즈마는 적은 양의 플라즈마 기체만 필요하여(약 1.6 L/min) 경제적이며 매우 안정된 형태를 보여주었다. 플라즈마의 분광특성을 조사한 결과 들뜸온도 4950K, 전자밀도 $3.28{\times}10^{14}cm^{-3}$로 측정되었다.
가중치가 부과된 Bit-flipping 기법을 이용한 LDPC 코딩
조경현,나극환 대한전자공학회 2006 電子工學會論文誌 IE (Industry electronics) Vol.43 No.4
In this paper, we proposed about data error check and correction on channel transmission in the communication system. LDPC codes are used for minimizing channel errors by modeling AWGN Channel as a VDSL system. Because LDPC Codes use low density parity bit, mathematical complexity is low and relating processing time becomes shorten. Also, the performance of LDPC code is better than that of turbo code in long code word on iterative decoding algorithm. This algorithm is better than conventional algorithms to correct errors, the proposed algorithm assigns weights for errors concerning parity bits. The proposed weighted Bit-flipping algorithm is better than the conventional Bit-flipping algorithm and we are recognized improve gain rate of 1 dB. 본 논문에서는 통신 시스템에서 채널 전송에 의한 데이터의 오류 체크와 정정문제에 대해서 제안하였다. 제안된 LDPC 코드는 VDSL 시스템에서의 AWGN 채널 모델링에 의해 최소화된 채널 에러를 위해 사용된다. LDPC 코드는 낮은 밀도 패리티 비트를 사용하기 때문에, 수학적인 복잡도가 낮고 처리 시간이 짧다. 또한 LDPC 코드의 성능은 반복 복호 알고리즘에서 긴 코드 워드에 대해 터보 코드보다 더 나은 성능을 가지고 있다 제안된 시스템의 송신기에서 발생 행렬에 의해서 부호어가 발생되고, 수신기에서 사용된 에러 정정 알고리즘은 가중치를 갖는 Bit-flipping 방식이다. 이 방식은 기존의 Bit-flipping 방식과 달리 더 정확한 에러를 검출하고, 정정하기 위해 발생된 패리티 비트에 대해서 가중치를 주어 에러 정정을 하는 방식이다. 제안된 가중치를 갖는 Bit-flipping 알고리즘은 기존의 Bit-flipping 알고리즘에 비해서 1 dB 이상의 이득 개선을 확인할 수 있었다.