http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Gonzalez-Vizcarra, Victor Manuel,Plascencia, Alejandro,Ramos-Avina, Daniel,Zinn, Richard Avery Asian Australasian Association of Animal Productio 2017 Animal Bioscience Vol.30 No.11
Objective: The influence of substituting steam-flaked corn (SFC) for dry rolled corn (DRC) on feedlot cattle growth performance and dietary net energy when cattle are allowed either ad libitum or 2-h restricted access to the finishing diet was evaluated. Methods: Treatment effects were tested using 96 crossbred steers ($251{\pm}2kg$) during the initial 56 d of the finishing phase. Cattle were blocked by weight and randomly assigned within blocks to 16 pens (4 pens/treatment). Bunk space was sufficient (41 cm/head) to allow all steers access to the feed bunk at the same time. Treatments consisted of two finishing diets containing (dry matter basis) 77.1% corn grain processed by dry rolling (density = 0.50 kg/L) or steam flaking (density = 0.36 kg/L). Cattle were fed twice daily at 06:00 and 14:00 h, allowing for approximately 5% residual. In the case of restricted feeding, steers were allowed access to feeders for 1 h following each feeding, after which residual feed was withdrawn. Results: There were no treatment interactions on dry matter intake (DMI), average daily gain (ADG), gain efficiency (G:F), or dietary net energy (NE). Restricting feed access time reduced (p<0.01) feed intake, and hence, ADG. Substitution of SFC for DRC increased (p<0.01) ADG, feed efficiency (G:F), and estimated dietary NE, without affecting DMI. Based on tabular net energy of maintenance ($NE_m$) value (2.18 Mcal/kg) for DRC, the estimated $NE_m$ value for SFC using the replacement technique, averaged 2.44 Mcal/kg; an improvement of 10.7%. The ratio of observed-to-expected dietary NE was not affected by feed access time. Conclusion: Substitution of SFC for DRC in finishing diets for feedlot cattle enhanced ADG, gain efficiency, and the NE value of the diet. Although restriction of feed access time depressed DMI and ADG, it did not affect the comparative benefit of steam flaking toward enhancement of ADG, G:F, and dietary NE.
Gonzalez-Cantu, Cynthia Minerva,Moreno-Pena, Pablo Juan,Salazar-Lara, Mayela Guadalupe,Garcia, Pablo Patricio Flores,Montes-Tapia, Fernando Felix,Cervantes-Kardasch, Victor Hugo,Castro-Govea, Yanko Korean Society of Plastic and Reconstructive Surge 2021 Archives of Plastic Surgery Vol.48 No.5
Epignathus is a rare congenital orofacial teratoma that arises from the sphenoid region of the palate or the pharynx. It occurs in approximately 1:35,000 to 1:200,000 live births representing 2% to 9% of all teratomas. We present the case of a newborn of 39.4 weeks of gestation with a tumor that occupied the entire oral cavity. The patient was delivered by cesarean section. Oral resection was managed by pediatric surgery. Plastic surgery used virtual 3-dimensional models to establish the extension, and depth of the tumor. Bloc resection and reconstruction of the epignathus were performed. The mass was diagnosed as a mature teratoma associated with cleft lip and palate, nasoethmoidal meningocele that conditions hypertelorism, and a pseudomacrostoma. Tridimensional technology was applied to plan the surgical intervention. It contributed to a better understanding of the relationships between the tumor and the adjacent structures. This optimized the surgical approach and outcome.
Code-Centric RFID System Based on Software Agent Intelligence
Min Chen,Gonzalez, Sergio,Qian Zhang,Leung, Victor C M IEEE 2010 IEEE INTELLIGENT SYSTEMS Vol.25 No.2
<P>Radiofrequency identification (RFID) technology could play a vital role in future smart-environment applications. This code-centric RFID system uses software-agent based intelligence to achieve faster service responses.</P>
A parametric study of optimum tall piers for railway bridge viaducts
Martinez-Martin, Francisco J.,Gonzalez-Vidosa, Fernando,Hospitaler, Antonio,Yepes, Victor Techno-Press 2013 Structural Engineering and Mechanics, An Int'l Jou Vol.45 No.6
This paper presents a parametric study of reinforced concrete bridge tall piers with hollow, rectangular sections. Such piers are typically used in railway construction of prestressed concrete viaducts. Twenty one different piers have been studied with seven column heights of 40, 50, 60, 70, 80, 90 and 100 m and three types of 10-span continuous viaducts, whose main span lengths are 40, 50 and 60 m. The piers studied are intermediate columns placed in the middle of the viaducts. The total number of optimization design variables varies from 139 for piers with column height of 40 m to 307 for piers with column height of 100 m. Further, the results presented are of much value for the preliminary design of the piers of prestressed concrete viaducts of high speed railway lines.
Vera-Cabrera, Lucio,Gonzalez, Eva,Rendon, Adrian,Ocampo-Candiani, Jorge,Welsh, Oliverio,Velazquez-Moreno, Victor M.,Hak Choi, Sung,Molina-Torres, Carmen American Society for Microbiology 2006 Antimicrobial agents and chemotherapy Vol.50 No.9
<B>ABSTRACT</B><P>The in vitro activities of DA-7157, a novel oxazolidinone, against clinical isolates of <I>Nocardia brasiliensis</I> and <I>Mycobacterium tuberculosis</I> were determined. Equal MIC50s and MIC90s (0.25 and 0.5 μg/ml, respectively) were found for susceptible and multidrug-resistant isolates of <I>M. tuberculosis</I>. The <I>N. brasiliensis</I> isolates showed an MIC90 of 1 μg/ml and an MIC50 of 1 μg/ml. The DA-7157 prodrug, DA-7218, exhibited similar MICs for <I>M. tuberculosis</I> but fivefold-higher MICs for <I>N. brasiliensis</I>.</P>
( Dixie May ),( Jose F Calderon ),( Victor M Gonzalez ),( Martin Montano ),( Alejandro Plascencia ),( Jaime Salinas-chavira ),( Noemi Torrentera ),( Richard A Zinn ) 한국동물자원과학회(구 한국축산학회) 2014 한국축산학회지 Vol.56 No.14
Two trials were conducted to evaluate the influence of supplemental urea withdrawal on characteristics of digestion (Trial 1) and growth performance (Trial 2) of feedlot cattle during the last 40 days on feed. Treatments consisted of a steam-flaked corn-based finishing diet supplemented with urea to provide urea fermentation potential (UFP) of 0, 0.6, and 1.2%. In Trial 1, six Holstein steers (160 ± 10 kg) with cannulas in the rumen and proximal duodenum were used in a replicated 3 × 3 Latin square experiment. Decreasing supplemental urea decreased (linear effect, P ≤ 0.05) ruminal OM digestion. This effect was mediated by decreases (linear effect, P ≤ 0.05) in ruminal digestibility of NDF and N. Passage of non-ammonia and microbial N (MN) to the small intestine decreased (linear effect, P = 0.04) with decreasing dietary urea level. Total tract digestion of OM (linear effect, P = 0.06), NDF (linear effect, P = 0.07), N (linear effect, P = 0.04) and dietary DE (linear effect, P = 0.05) decreased with decreasing urea level. Treatment effects on total tract starch digestion, although numerically small, likewise tended (linear effect, P = 0.11) to decrease with decreasing urea level. Decreased fiber digestion accounted for 51% of the variation in OM digestion. Ruminal pH was not affected by treatments averaging 5.82. Decreasing urea level decreased (linear effect, P ≤ 0.05) ruminal N-NH and blood urea nitrogen. In Trial 2, 90 crossbred steers (468 kg ± 8), were used in a 40 d feeding trial (5 steers/pen, 6 pens/ treatment) to evaluate treatment effects on final-phase growth performance. Decreasing urea level did not affect DMI, but decreased (linear effect, P ≤ 0.03) ADG, gain efficiency, and dietary NE. It is concluded that in addition to effects on metabolizable amino acid flow to the small intestine, depriving cattle of otherwise ruminally degradable N (RDP) during the late finishing phase may negatively impact site and extent of digestion of OM, depressing ADG, gain efficiency, and dietary NE.
Gutierrez-Vargas, Gildardo,Ruiz, Alberto,Lopez-Morelos, Victor H.,Kim, Jin-Yeon,Gonzalez-Sanchez, Jorge,Medina-Flores, Ariosto Korean Nuclear Society 2021 Nuclear Engineering and Technology Vol.53 No.9
One of the consequences of the 475 ℃ embrittlement of duplex stainless steels is the reduction of the resistance to localized corrosion. Therefore, the detection of this type of embrittlement before the material exhibits significant loss in toughness, and corrosion resistance is important to ensure the structural integrity of critical components under corrosion threats. In this research, conductivity measurements are performed using the alternating current potential drop (ACPD) technique with using a portable four-point probe as a nondestructive evaluation (NDE) method for detecting the embrittlement in a 2507 (UNS S32750) super duplex stainless steel (SDSS) aged at 475 ℃ from as-received condition to 300 h. The electric conductivity results were compared against two electrochemical tests namely double loop electrochemical potentiokinetic reactivation (DL-EPR) and critical pitting temperature (CPT). Mechanical tests and the microstructure characterized using scanning electron microscopy (SEM) imaging are conducted to track the progress of embrittlement. It is shown that the electric conductivity correlates with the changes in impact energy, microhardness, and CPT corrosion tests result demonstrating the feasibility of the four-point probe as a possible field-deployable method for evaluating the 475 ℃ embrittlement of 2507 SDSS.
Alejandro Tapia-Hernandez,Mario Ponce-Silva,Victor Hugo Olivares-Peregrino,Jesus Elias Valdez-Resendiz,Leobardo Hernandez-Gonzalez 전력전자학회 2017 JOURNAL OF POWER ELECTRONICS Vol.17 No.4
The main contribution of this paper is the use of sensorless active diodes to generate the gate signals for a three-phase boost-rectifier with a self-powered control scheme. The sensorless operation is achieved making use of the gate control signals generated by the active diode schemes on each of the switching devices using a pulse width half-controlled boost rectifier modulation technique (PWM-HCBR). The proposed scheme synchronizes the gate control signals with a three phase voltage supply. Autonomous operation is obtained making use of the output DC bus to feed the control circuitry, the active diodes and the driver circuitry. The three-phase boost-rectifier is supplied by a three-phase permanent magnet electric generator powered by a solar concentrator dish with variable voltage and variable frequency conditions. Experimental results report an efficiency of up to 94.6% for 25 W and an input of 3.6 V peak per phase with 450.