http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
2-Dimensional Model Development for Water Quality Prediction
Do Hyeon Paik 한국환경보건학회 2005 한국환경보건학회지 Vol.31 No.6
:A numerical method for the mathematical water modeling in 2-dimensional flow has been developed. The model based on a split operator technique, in which, the advection term is calculated using the upwind scheme. The diffusion term is one- dimensionalized and calculated using Crank-Nicholsons implicit finite difference scheme to reduce the numerical errors from large time steps and variable spacings. It also provides a relatively simple and economic method for more accurate simulation of pollutant dispersion. Water depths and flow velocities in the Boreyong reservoir during the normal water periods were predicted by numerical experiments with a 2-dimensional flow model so as to provide current field data for the study of advection and diffusion of pollutants. Developed 2-dimensional water quality model is applied to Boreyong reservoir to simulate a spatial and periodical changes of water quality.
Kim, Do-Hee,Lee, Hyun-Jung,Choi, Gooi-Hun,Kim, Ok-Hyeon,Lee, Kwang-Gill,Yeo, Joo-Hong,Lee, Jun-Young,Lee, Sang-Hyung,Youn, Young-Chul,Lee, Jang-Han,Paik, Hyun-Dong,Lee, Won-Bok,Kim, Sung-Su,Jung, Hee- Korean Society for Food Science of Animal Resource 2009 한국축산식품학회지 Vol.29 No.2
Previous studies indicate that BF-7 enhances learning and memory in normal and elderly individuals. Here, we evaluated whether milk containing BF-7 (BF-7 milk) could improve the brain function, with thirty normal university students $(21{\pm}1.2 years)$. Two versions of the Paced Auditory Serial Addition Test were used under double-blinded conditions to measure the efficacy of BF-7 milk on learning and memory, especially working memory and attention, and on mathematical ability. As a result, BF-7 milk improved the accuracy of the task more than 3-fold. Furthermore, BF-7 milk protected cultured neuronal cells from 3-hydroxykynurenine, a normal endogenous brain stress agent. These results indicate that BF-7 milk enhances memory, attention and mathematical ability in normal persons.
Rapid gas chromatographic profiling and screening of biologically active amines
Kim, Kyoung Rae,Paik, Man Jeong,Kim, Jung Han,Dong, Suk Won,Jeong, Do Hyeon 성균관대학교 약학연구소 1997 成均藥硏論文集 Vol.9 No.1
An efficient method is described for the simultaneous determination of 57 amines including volatile aliphatic amines, nonvolatile polyamines and catecholamines present in aqueous samples. The mothod is based on two-phase isobutyloxycarbonylation (isoBOC) with a pH shift. In 1.0 M phosphate buffer at pH 7.5, phenolic hydroxyl groups were allowed to react with isobutyl chloroformate in the dichloromethane phase, and subsequently pH of the aqueous phase was increased to 12.0 for the reaction of basic amino functions. The resulting N(O)-isoBOC amines were recovered by solid-phase extraction using Chromosorb P in normal phase partition mode, with subsequent tert.-butyldimethylsilylation of the remaining hydroxyl groups for gas chromatographic analysis. Using this combined procedure, linear responses were obtained in the concentration range of 0.2-12 ppm, with correlation coefficients varying from 0.945 to 0.999 for most of the amines studied except for 5-methoxytryptamine (0.864). Temperature-programmed retention index(I) sets as measured on DB-5 and DB-17 dual-capillary columns of different polarity were characteristic of each amine and thus, useful in the screening for amines by computer I matching. When applied to saliva samples, the present method allowed rapid screening for each spiked amine and unspiked polyamines such as 1,3-diaminopropane, putrescine, cadaverine and spermidine.
A Study on Runoff Characteristics of Combined Sewer Overflow(CSO) in Urban Area Using GIS & SWMM
Jae Hoon Kim,Do Hyeon Paik 한국환경보건학회 2005 한국환경보건학회지 Vol.31 No.6
The runoff characteristics of combined sewer overflow(CSO) in the urban area of Jeonju were investigated and analyzed by using the SWMM (Storm Water Management Model) and GIS. From August to November 2004, investigations on two rainfall events were performed and flowrate, pH, BOD, COD, SS, T-N and T-P were measured. these data were used for model calibration.Using GIS technique, watershed characteristics of study area were calculated. that is, divide into sub_basin, total width, slope, make soil map etc. On the basis of the measured data and the simulation results by SWMM, it could be known that the 80-90% of pollution load are discharged in early-stage storm runoff. SMC(site mean Concentration) for combined sewer system area were BOD 28.1, COD 31.5, SS 186 ppm etc. this is shown that during the rain fall, high concentration of waste was loaded to receiving water. Unit loads of combined sewer system area were BOD 306, COD 410, SS 789, T-N 79, T-P 6.8 kg/ha/yr.
윤충식,백도현,Yoon, Chung-Sik,Paik, Do-Hyeon 한국환경보건학회 2006 한국환경보건학회지 Vol.32 No.1
This study was performed to investigate airborne lead concentration and surface lead contents in preschool facilities. Arithmetic mean of indoor lead concentration in urban area was $44.7\;ng/m^3$ (Geometric mean $32.1\;ng/m^3$) whereas outdoor concentration was $39.5\;ng/m^3$ (GM $22.8\;ng/m^3$). In rural area, airborne lead concentrations were $14.2\;ng/m^3\;(GM\;7.9 ng/m^3),\;12.6\;ng/m^3\;(GM\;5.6 ng/m^3)$, respectively. There is statistical significance of the lead concentrations among the locations of preschool facilities. About $37\%$ of qualitative lead check samples was positive and mainly was found in lead based paint. Though lead concentrations on the floor and window sill were well below the US EPA and HUD standard (floor $40\;{\mu}g/ft^2\;(4.3\;{\mu}g/100\;cm^2)$, window sill $250\;{\mu}g/ft^2\;(26.9\;{\mu}g/100\;cm^2)$, respectively), there were much samples which exceed the standard, i.e., $29\%$ of surface wall, $20\%$ of the desk and chair, $100\%$ of painted wood box of tested samples. In view of our study and hazard of lead to children, we recommended that the contents of lead in preschool facilities should be lowered as possible.
미생물 성장을 억제하기 위하여 수용성 절삭유에 과다하게 첨가한 붕소와 아민 사례 연구
박동욱 ( Dong Uk Park ),백도현 ( Do Hyeon Paik ) 한국산업위생학회 2005 한국산업보건학회지 Vol.15 No.3
This study was conducted to examine whether a specific synthetic metalworking fluid (MWF), "A", in use for 10 months without replacement, displayed microbial resistance and to identify the additives associated with the control of microbial growth. Three synthetic MWF products ("A", "B", and "C") were studied every week for two months. Microbial deterioration of the fluids was assessed through evaluation by endotoxin, bacteria and fungi levels in the MWFs. In addition, formaldehyde, boron, ethanolamine, and copper levels were also studied to determine whether they influence microbial growth in water-based MWFs. Throughout the entire study in the sump where MWF "A" was used, bacteria counts were lower than 103 CFU/mL, and endotoxins never exceeded 103 EU/mL. These levels were significantly lower than levels observed in sumps badly deteriorated with microbes. Boron levels in MWF "A" ranged from 91.7 to 129.6 ppm, which was significantly higher than boron levels found in other MWF products. The total level of ethanolamine (EA) in MWF "A" ranged from 35,595 to 57,857 ppm (average 40,903 ppm), which was over ten times higher than that found in other MWFs. Monoethanolamine (MEA), diethanolamine (DEA) and triethanolamine (TEA) concentrations in MWF "A" were also significantly higher than seen in other MWFs. However, although EA and boron might improve anti-microbial performance, their abuse can pose a serious risk to workers who handle MWFs. From an industrial hygiene perspective, our study results stress that the positive synergistic effect of boron and EA in reducing microbial activity in MWF must be balanced with the potentially negative health effects of such additives. Our study also addresses the disadvantage of failing to comprehensively report MWF additives on Material Safety Data Sheets (MSDS). Future research in MWF formulation is needed to find the best level of EA and boron for achieving optimal synergistic anti-microbial effects while minimizing employee health hazards.