http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
손량희(Ryanghee Sohn),최희석(Heuseok Choi),조승관(Seungkwan Cho),김한성(Hansung Kim),김영호(Youngho Kim) 대한기계학회 2008 대한기계학회 춘추학술대회 Vol.2008 No.5
We were performed the three dimensional motion analysis for the 'Arthritis Knee Brace(AKB)' which has widening effects on the knee joint condylar separation. The knee joint condylar separations were measured at 1.807㎜(lateral), 0.474㎜(center) and 2. 172㎜(medial) by the fluoroscopy. Finite elememt method result in condylar stress decrease at 3.951㎫ in femur and 4.556㎫ in tibia. However, three dimensional gait analysis showed that all three lower joints(hip, knee ankle) were more flexed during AKB walking, and ground reaction force was larger in AKB walking just before the push-off. In the future, the joint moment and power as well as the electromyogram have to be analyzed to find the biomechanical disadvantage of AKB.
중증지체장애인을 위한 스마트 홈 구축 및 사용성 평가 : 중증장애인 삶의 질 향상을 위한 주거 환경 기반 구축
손량희(Ryanghee Sohn),임명준(Myungjoon Lim),임신영(Shinyoung Lim),김정현(Junghyun Kim),김종배(Jongbae Kim) 한국HCI학회 2012 한국HCI학회 학술대회 Vol.2012 No.1
본 연구의 목적은 중증지체장애인을 위한 스마트 홈 개발 및 사용성 평가에 있다. 스마트 홈을 개발하기 위한 예비 연구로서 임상 전문가, 장애인 단체, 중증지체장애인을 대상으로 전문 자문 그룹으로 구성하였고, 스마트 홈 시스템의 필요와 사용에 대해 조사하였다. 조사 결과, 시스템의 중요한 디자인 개념에 대한 많은 응답을 얻을 수 있었다. 본 연구에서 개발된 시스템을 통하여 중증지체 장애인의 삶의 질 및 자립생활 능력 향상에 도움을 줄 것으로 기대한다. The purpose of this study is to develop and perform user testing of smart home for the people with severe disability. As a preliminary study for the development of the smart home system, the expert groups consisted of clinical experts, people from disability associations and people with severe disability were surveyed by the needs and usages to improve residential environment. From the respond of the survey, we have found number of issues that lead us to key design concepts about smart home. In this paper, we have developed smart home system based on survey results. We expect that the use of the developed systems will help to provide a way for the people with severe disability to improve the level of independence and the quality of life.
Youjung Seo(서유정),Wongyu Lee(이원규),Ryanghee Sohn(손량희),Cheolsoo Park(박철수) 대한전자공학회 2020 대한전자공학회 학술대회 Vol.2020 No.11
By adding wrist blood pressure (BP) monitor to estimate BP, a novel way of BP calibration method is proposed in this paper. This paper uses ECG, PPG signals as input and the prediction model is inspired by a combination of CNN (Convolutional Neural Network) and LSTM (Long short term memory).
마비환자의 보행훈련을 위한 로봇형 보행훈련 시스템 개발
황성재(Sungjae Hwang),김정윤(Jungyoon Kim),손종상(Jongsang Son),손량희(Ryanghee Sohn),김영호(Youngho Kim) 대한기계학회 2008 대한기계학회 춘추학술대회 Vol.2008 No.5
In this study, we developed a robotic gait training system which induces the active gait training based on predefined continuous proper lower extremity joint movements for the paralysis. AC servo motors and linear actuators were used to control hip and knee joints of patients and the weight support system was used to support the patient's weight during the gait training. We also implemented a GUI program to set the gait training pattern with several training parameters and to confirm states of patients and the system through the visual feedback. The effectiveness of the gait training system will be determined by the long-term clinical experiments in the future. We expect that the developed robotic gait training system could be applied very practically to recover gait abilities for persons with gait disorder.
장애인의 삶의 질 향상 제품에 대한 사용성 평가 시 HCI 기법의 적용 : 장애인 삶의 질 향상 제품의 사용성 평가 과정에서 HCI 기법을 이용한 정량적 근거 산출 방안
임신영(Shinyoung Lim),김종배(Jongbae Kim),김정현(Junghyun Kim),손량희(Ryanghee Sohn),임명준(Myungjoon Lim) 한국HCI학회 2012 한국HCI학회 학술대회 Vol.2012 No.1
사용성 평가는 다양한 분야에서 사용자의 제품 사용 측면에 대한 평가 기법으로 적용되어 왔다. 최근 장애인을 위한 재활보조기기 및 삶의 질 향상을 위한 제품에 대한 사용성 평가는 정립되어 가는 과정에 있다. 본 논문은 이와 같은 사용성 평가 과정에서 사용자의 제품 사용에 대한 동작 모니터링, 소요시간 및 에러 발생 측정을 통한 객관적인 근거를 제시할 목적으로 HCI 기법의 적용 가능성을 논하고자 한다. Usability assessment has been installed into a wide range of applications that assess product usage from the user's perspective. At present, the usability assessment of the assistive devices and quality of life products for the people with disability is under development. In this paper, applying HCI method to quantify each measuring step of activity monitoring, time consumption, and detecting errors in usability assessment for providing objective evidence is introduced to discuss feasibility of applying the HCI method.