미소유체역학 기술을 응용한 세포 이동 관찰 챔버의 개발 및 응용
이승열(S. Y. Lee),김명준(M. J. Kim),채상민(S. M. Chae),진송완(S. Jin) 대한기계학회 2010 대한기계학회 춘추학술대회 Vol.2010 No.11
In this paper, we applied various microfluidic chambers to study cell migration and measured the migration velocity in microchannels. Migration speed of B16 cell in a large channel was similar with that of wound healing experiment. However, the speed decreased gradually as the cell move inside the channel. It is expected that this phenomenon is due to the shortage of oxygen or nutrition, which are essential for cell growth. In the case of cell in the small channel whose size is smaller than cell, its speed was slower than larger channel. Also, the speed decreased as the width of the channel decreased.