Shut-off 밸브를 부착한 LPLi 인젝터 팁에서의 빙결 현상 연구
이종필(Jongpil Yi),이종화(Jonghwa Lee),박진일(Jinil Park) 한국자동차공학회 2005 한국자동차공학회 춘 추계 학술대회 논문집 Vol.2005 No.11_1
Since Liquid Petroleum Gas(LPG) absorbs heat to evaporate when it is injected in atmosphere pressure. the temperature of injector tips is decreased even below freezing in LPLi system. Inside intake manifold. vapor among fresh charge passing the cold injector can stick and glow on the surface of the injector as a form of ice. The phenomenon called Icing is paid attention, when it interferes with engine management by its ice particles flowed into cylinder. As a result of injection visualization, emission analysis, and study about engine running circumstance, these icing phenomenons are classified two types roughly; the one from cold adapter surface and the other one from Teflon tube tip placed in the center of injector adapters. Icing on adapter surface is significantly moderated by encouraging heat transfer between cold injector tips and hot induct manifold in a LPLi injector employed shut-off valve.