http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
신용승(Yong Seung Shin),서은숙(Eun Sook Suh),신상만(Sang Man Shin) 대한소아신경학회 1996 대한소아신경학회지 Vol.3 No.2
Adrenoleukodystrophy is an inborn error of metabolism characterized by adrenal insufficiency and progressive demyelination of brain white matter and peripheral nerve. Authors experiensed a case of adrenoleukodystrophy in a 10-year-old boy, who had seizure, headache, progressive auditory impairment, white matter lesion in brain MRI, and increased saturated very long chain fatty acid in plasma. We reported it with a brief review of literatures.
경피용 BCG 백신의 PPD 1TU, 2TU 및 5TU 결핵 피부반응 검사에 대한 영향
김보선,황민호,김창휘,박재옥,신상만,Kim, Bo Sun,Hwang, Min Ho,Kim, Chang Hwi,Park, Jae Ok,Shin, Sang Man 대한소아감염학회 2001 Pediatric Infection and Vaccine Vol.8 No.2
목 적 : 최근 국내에서 1998년부터 5TU 대신 2TU를 사용함으로써 결과 판정에 어려움이 있다. 5TU와 2TU에 대한 투베르쿨린 반응 정도는 차이가 있게 마련이나 아직까지 적절한 국내 기준이 마련되어 있지 않은 실정이기에 생후 4주 이내에 경피 다자법으로 BCG를 접종 받은 영아에서의 PPD 1TU, 2TU 및 5TU에 대한 반응을 관찰하고자 하였다. 방 법 : 2000년 1월부터 2000년 8월까지 8개월간 순천향대학병원 육아지도회에서 결핵의 가족력, 피부 질환, 영양 장애 및 면역 기능 저하 소견이 없는 건강한 신생아 중 생후 4주 이내에 경피 다자법(Tokyo strain, Japan BCG Laboratory Co.)으로 BCG를 접종한 92명(남아 : 56명, 여아 : 36명)에게 생후 4개월에 PPD 1TU, 2TU 및 5TU로 결핵 피부반응 검사를 시행한 후 그 반응을 관찰하였다. 통계처리는 통계 프로그램인 SPSS 10.0을 이용하여 ANOVA, Chi-square test을 적용하여 P<0.05인 경우 통계적으로 유의하다고 판단하였다. 결 과 : 1) 전체 92명 중 31명에서 1TU, 31명에서 2TU 그리고 30명에서는 5TU를 사용하여 결핵 피부반응 검사를 시행하였다. 1TU로 검사시 경결의 크기가 0 mm인 경우가 가장 많았고 그 다음으로 7 mm, 6 mm 순으로 많았다. 2TU로 검사시 경우 8 mm가 가장 많았으며 그 다음은 3 mm, 6 mm, 10 mm가 많았다. 5TU로 검사시 13 mm와 6 mm가 가장 많았다. 2) 경결의 평균 크기는 PPD 1TU, 2TU 및 5TU로 검사하였을 때 각각 $5.7{\pm}4.2mm$, $7.1{\pm}3.7mm$, $9.2{\pm}4.2mm$로 1TU와 2TU는 통계학적으로 차이가 없었으나 5TU의 경우 PPD 1, 2TU에 비해 평균 경결 크기가 의미 있게 컸다(P<0.05). 3) 경결의 크기가 10 mm 이상인 경우는 1TU에서는 31명 중 6명(19.4%), 2TU에서는 31명 중 9명(29%), 5TU에서는 30명 중 16명(53.3%)이었으며 1TU와 2TU는 통계학적으로 차이가 없었으나 5TU의 경우 PPD 1, 2TU에 비해 의미 있게 많았다(P<0.05). 경결의 크기가 5 mm 이상인 경우는 통계학적 유의성은 없었지만 5TU로 검사시 가장 많았다. BCG 반흔 수는 1TU의 경우 $13.81{\pm}4.48$개, 2TU는 $13.06{\pm}4.18$개, 5TU는 $13.07{\pm}3.07$개로 차이가 없었다. 결 론 : 현재 국내에서 사용되고 있는 2TU을 사용한 결핵 피부반응 검사에 대한 새로운 평가 기준이 필요하고 결핵의 진단기준에 대한 더 많은 연구가 필요하다고 사료된다. Purpose : Recently in Korea since 1998, 2TU has been used instead of 5TU, which caused a confusion in interpreting tuberculin skin tests. We compared the tuberculin skin reaction to PPD(purified protein derivatives) 1TU, 2TU and 5TU. Methods : We studied tuberculin skin reaction to PPD 1TU, 2TU and 5TU on 92 infants who were vaccinated with percutaneous multiple puncture BCG vaccine(Tokyo 172 strain, Japan BCG Laboratory Co.) in neonatal period. Diameters of indurations were measured in millimeters 48~72 hours after the intradermal injection of PPD 1TU, 2TU and 5TU. Results : Among 92 infants(male : 56, female : 36), 1TU was used on 31 infants, 2TU on 31 infants and 5TU on 30 infants for tuberculin skin test. The mean diameter of induration for PPD 1TU, 2TU and 5TU were $5.7{\pm}4.2mm$, $7.1{\pm}3.7mm$, and $9.2{\pm}4.2mm$, respectively. There was no statistical difference in mean diameter of induration between 1TU and 2TU. However, when tested with 5TU, the diameter of induration was significantly larger than those of PPD 1TU and 2TU(P<0.05). Six subjects(19.4%) tested with 1TU, 9 subjects(29%) tested with 2TU and 16 subjects(53.3%) tested with 5TU had diameter of 10 mm or more. There was no statistical difference between 1TU and 2TU but for 5TU, number of subjects with diameter of 10 mm or more was significantly higher than PPD 1TU and 2TU(P<0.05). Number of subjects with induration diameter of 5 mm or more for 1TU, 2TU and 5TU was 19(61.3%), 22(71.0%) and 26(86.7%), respectively. However, there was no statistical difference. Conclusion : A new standard criteria for interpreting the tuberculin skin test with PPD 2TU should be established for clinical diagnosis of tuberculosis.
Piezoresistive Microcantilever를 이용한 유방암 세포의 주파수 특성 평가
심상조(Sangjo Shim),조경우(Kyoungwoo Jo),김만근(Man Geun Kim),강용석(Young Seok Kang),신상모(Sang-Mo Shin),이종현(Jong-Hyun Lee) 대한기계학회 2008 대한기계학회 춘추학술대회 Vol.2008 No.5
Although use of chemical and biological markers has been widely used by numerous oncologists, there may be problems such complex and time consuming procedure. Recently, the relationships among the cell structure and the mechanical properties have been studied because the cancer cells can be characterized by varying mechanical properties associated with the disease state. In this paper, a novel characterization method for a breast cancer cell (MCF7) and normal cell (MCF10A) is suggested using frequency response through cell deformation. A single cell is placed on the laminated PZT actuator, and the microcantilever, which does not have a sharp tip, but a flat contact surface, is placed on the upper surface of the cell to deform the whole cell. The PZT actuator excites the single cell and its deformation is then evaluated from the displacement of the cantilever by measuring the voltage output through a piezoresistive sensor. These results indicate the higher frequencies and pre loads offer the larger differences between the cancer and normal cells, which is enough to diagnose them in magnitude and phase.