http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
박종흥,노홍구,이재헌,Park, Jong-Heung,No, Hong-Gu,Lee, Jae-Heon 대한기계학회 1998 大韓機械學會論文集B Vol.22 No.3
Numerical and experimental studies on a heat pipe with two heat sources have been performed to investigate the operating characteristics. Numerical analysis was performed based on the cylindrical two-dimensional incompressible laminar flow for the vapor space and the conjugate heat transfer for the entire heat pipe. Experimental study with a 0.45 m length copper-water heat pipe was also performed to validate the numerical modeling for the heat input range from 29 W to 47 W on each heater. As results, the temperature profiles at the outer wall for the single active heat source as well as the temperature profiles for the switching operation between two heat sources are suggested. Due to the axial conduction, it is found that the temperature drop between the evaporator and the condenser appears small when the heat source closer to the condenser is turned on. For the switching operation in the present study, the transient time is about 700s and the temperatures at the locations of both heat source are same in 130s after switching.
CALCULATION OF FLOW FIFLD IN A CHANNEL SUBJECTED TO PRESSURE-BASED BOUNDARY CONDITION
박종흥,이재헌,Park, Jong-Hyeong,Lee, Jae-Hyeon 한국전자통신연구원 1988 전자통신 Vol.10 No.4
A numerical analysis was performed for the flow field in the vertical channels consist of dummy cards and active cards to define the hydrodynamic role of dummy card which is often installed in electronic equipment between active cards to control the cooling air distribution. For a given velocity profile at the inlet and a pressure-based boundary condition at the outlet of the computation domain, the percentage of the flow rate distribution through active channel and dummy channel formed by an active card and dummy card, respectively, were investigated. As a result of present analysis, the pecentage of flow rate through active channel increases quadraticaly with the increase of the ratio of the height of barrier to the width of the dummy channel.
물류 산업의 텔레매틱스 기술 적용 방안 및 서비스 동향
박종흥,이상락,김은혜,Park, Jong-Heung,Lee, Sang-Rak,Kim, Eun-Hye 한국전자통신연구원 2008 전자통신동향분석 Vol.23 No.4
고객으로부터 물품의 주문, 물품 생산, 출하, 상차, 배송 그리고 고객 인도로 이루어지는 SCM 상의 사이클에 있어서 운송 부분은 물류비의 50% 이상을 차지하고 있다. 일반적인 화물 운송의 경우 차량 단위로 적재하여 운송하게 되며, 이러한 차량의 운송비 절감은 수배송 경로 최적화, 차량 운행 및 상태 관리를 통한 운송 계획의 효율화, 차량의 혼적 운송, 공차율 감소 그리고 배차 관리를 통해 이루어질 수 있다. 이에 본 고에서는 물류 운송단계에서 운송 계획의 효율화와 운송비를 절감하기 위하여 적용 가능한 텔레매틱스 기술에 대해 살펴보고 물류 산업 적용 방안 및 관련 서비스 동향에 대해서 살펴보고자 한다.
박종흥,이재헌,Park, Jong-Heung,Lee, Jae-Heon 대한기계학회 1996 大韓機械學會論文集B Vol.20 No.7
High-power electronic chips have been advanced to such an extent that the heat dissipation capability of a system design has become one of the primary limiting factors. Therefore, thermal design must be considered in the early stage of the electronic system development. In present paper, the results of an experimental study on the forced convection cooling are presented to evaluate cooling performance of an electronic cabinet which in generally used for telecommunication system. Temperatures and thermal resistances are applied to compare the heat transfer characteristics for various locations of a fan unit as well as various configuration of non-uniform powering modules. As a result, the optimal configuration of a fan unit and powering configuration is suggested for the effective thermal design of telecommunication system.
박종흥,송규섭,정명영,Park, Jong-Heung,Song, Gyu-Sup,Jeong, Myeong-Yeong 한국전자통신연구원 1987 전자통신 Vol.9 No.3
반도체 집적 기술의 개발과 실장 기술의 발전으로 전자장치는 점점 열밀도가 높아지고 있다. 여기서는 PBA가 수직으로 배치된 전자장치를 대상으로, 먼저 자연공냉과 PBA사이에서 발생하는 2차원 유동의 열적 특성을 고려한 후에, 최고 온도 상승률에 대하여 비대칭 열유속에서의 상한값과 대칭 열유속에서의 하한값을 구하는 과정을 기술하였다. 이것은 시스팀 설계 초기 단계에서 온도예측을 하여 시스팀 신뢰도를 향상시키도록 하기 위한 것이다.
TDX-1 전자교환기 고정용 앵커볼트 결합체의 강도해석
박종흥,송규섭,이용일,Park, Jong-Heung,Song, Gyu-Seop,Lee, Yong-Il 한국전자통신연구원 1986 전자통신 Vol.8 No.4
본고는 신뢰도상에서 점차 중요시 되어가고 있는 전자통신 장비의 기구물 및 시설의 안정성에 관한 논문으로서 TDX-1 전자교환기를 현장에 설치할 때 시스팀을 고정한 앵커볼트 결합체(앵커볼트+콘크리트 바닥) 에 대한 것이다. 이 앵커볼트 결합체에 하중이 가해졌을 경우 어떤 식으로 파괴가 일어나며, 어느 정도의 하중에서 파괴가 일어나는 가를 수치적 해석과 실험적인 방법으로 산출하여 그 안정성을 입증하였다.
박종흥,송규섭,허준영,임예섭,Park, Jong-Hyeong,Song, Gyu-Seop,Heo, Jun-Yeong,Im, Ye-Seop 한국전자통신연구원 1988 전자통신 Vol.10 No.3
In proportion to the increased density in electronic packaging from chip to system levels of telecommunication system, thermal management is becoming a vital subject to save the cost of the electronic product and to maintain high reliability. The key to the successful application of the thermal management technique is the capability to predict the equipment thermal behaviors in early stage of system development and product design. This paper describes the application of correlations of natural convection to TDX-10 digital switching system, which has been under the 5 year development project since 1987, in order to predict equipment temperature and thermal behaviors whihin a rack.
박종흥 정보통신정책연구원 2006 우정정보 Vol.2006 No.2
우편환경의 변화는 위기도 될 수 있고 기회도 될 수 있다. 통상우편의 감소로 절대 물량은 줄어들고 있지만 인터넷 대중화로 소포와 택배 물량이 증가하고 기업고객도 늘어나고 있다. 바코드 기반 우편프로세스로 이 우편환경 변화에 대응할 수 있으나 몇 년 내에 한계점에 도달할 것으로 보인다. 유통물류 분야에서 세계적으로 도입을 추진하고 있는 RFID 기술은 우편물류에서도 여러 가지 병목현상을 줄여줄 것으로 예상되고 실시간 정보 흐름으로 생산성 향상과 고객 만족도를 높일 수 있을 것으로 기대된다. 본고에서는 우편물류에 RFID 기술을 도입하는 경우 그 효과와 소요기술 및 문제점을 분석하고 중장기적인 로드맵을 제시한다.