http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
공동주택의 난방시스템 개선을 위한 실험 및 시뮬레이션 연구
김선동(Kim, Sun-Dong),김진우(Kim, Jin-Woo),김동영(Kim, Dong-Young),이경희(Lee, Kyung-Hee),박진철(Park, Jin-Chul) 대한건축학회 2012 대한건축학회논문집 Vol.28 No.7
At the present time, most Korean residential building depend on the radiant heating system. But this system leads to excessive heat supply by maintaining high level of floor temperature and creates a serious problem of energy overconsumption. In this study, therefore, suggest another or composite heating system that is better energy saving and more comfortable heating system by the mock-up test. And additionally have analysis about energy consumption and considered indoor heating distribution through CFD simulation. In the result, the existing radiant heating system is good for comfortable, but energy consumption is more worst than the air heating system. Therefore heating systems of apartment house are determined by heating zone’s characteristics.
김선동 ( Sundong Kim ),강민서 ( Minseo Kang ),이재길 ( Jae-gil Lee ) 한국정보처리학회 2014 한국정보처리학회 학술대회논문집 Vol.21 No.1
디비피디아 온톨로지는 위키피디아에서 구조화된 데이터를 추출한 지식 베이스이다. 이러한 지식 베이스의 자동 증강은 웹을 구조화하는 속도를 증가시키는데 큰 기여를 할 수 있다. 본 연구에서는 한국어 디비피디아를 기반으로 새로운 트리플을 입력받아 기존의 지식 베이스를 자동 증강시키는 시스템을 소개한다. 스키마를 자동 증강하는 두 가지 알고리즘은 최하위 레벨인 인스턴스가 지닌 프로퍼티,즉 rdf-triple 단위에서 진행되었다. 알고리즘을 사용한 결과 첫째,확률적 격상 방법을 통해 단계별로 입력받는 인스턴스와 하위 클래스의 프로퍼티를 이용하여 상위 클래스의 스키마가 정교해졌다. 둘째, 이를 바탕으로 타입 분류가 되어 있지 않았던 인스턴스들이 가장 가까운 타입에 자동 분류되었다. 지식 베이스가 정교해지면서 재분류된 인스턴스와 새로운 트리플셋을 바탕으로 두 가지 알고리즘은 반복적으로 작동하며,한국어 디비피디아 지식 베이스의 자동 증강을 이루었다.
김선동(Sun Dong Kim),이병희(Byung Hee Lee),전주영(Chu Young Chun) 대한설비공학회 2022 대한설비공학회 학술발표대회논문집 Vol.2022 No.6
라돈은 흡연과 더불어 두 번째로 높은 폐암 원인으로 전 세계의 폐암 사망의 3~20 %를 차지한다. 실내 라돈 저감을 위해 국토부, 환경부 등 다부처 중심의 천연 석재 기반의 라돈 관리 치침이 수립되었으나 이를 통한 실내 라돈농도 제어에 한계가 있다. 특히 이미 구축된 공동주택을 대상으로 건축자재의 라돈을 관리하기는 현실적으로 어려운 상황이다. 따라서 콘크리트 등 건축자재의 라돈 저감이 가능한 피막도포재, 차폐재 등을 활용하는 대안 마련이 필요하다. 본 연구에서는 콘크리트 등 건축자재에 도장재(페인트)를 적용하여 실내 표면에서 방출하는 라돈 방출량 감소 효과를 확인하고자 하였다. 건축자재의 라돈 방출 평가를 위해 석재를 사용하여 시편을 제작하였으며 각 시편별 도료 도장 전, 후에 따른 라돈 방출량을 측정 하였다. 또한, 챔버 실험을 통해 라돈 저감 효과가 있는 도장재 중 비용대비 저감 효과가 우수한 도료 1종을 사용하여 목업 실험을 진행하였다. 도장재 적용 전, 실내 라돈 농도는 빠른 속도로 증가하였으며 약 1,319 Bqm-3 내외에서 방사평형을 형성하는 것을 볼 수 있다. 도장재 마감 후, 도장재 마감 전에 비해 느린 속도로 실내 라돈 농도가 증가하였으며 약 522 Bqm-3 내외에서 실내 라돈 농도가 평형을 이루는 것을 확인할 수 있었다.
김선동(Sun Dong Kim),이병희(Byung Hee Lee),전주영(Chu Young Chun) 대한설비공학회 2020 대한설비공학회 학술발표대회논문집 Vol.2020 No.6
This study aims to investigate the relationship between the indoor radon concentration and floor level in residential buildings. There was used an electret ion chamber in middle point of living room for indoor radon level. It was measured indoor radon concentration for 2 days for each floor level (low, middle and high) in 19-story building and 21-story building. I And it was estimated average indoor radon concentration of all units and compared between floor levels and indoor radon levels by using one-way ANOVA. As a results, The average indoor radon concentrations of each floor level were slightly different, but there was not statistically significant (p>0.05).
김선동(Sun Dong Kim),이병희(Byung Hee Lee),전주영(Chu Young Chun) 대한설비공학회 2021 대한설비공학회 학술발표대회논문집 Vol.2021 No.6
Many European and few countries, much research has been done on radon concentrations in low-rise residential buildings. General type of residential buildings in many countries is low-rise housing, and the indoor radon level in ground floor tends to be higher than indoor radon level in upper floor. This study aims to investigate the relationship between the indoor radon concentration and floor level in residential building in Korea. So, in order to analyze the difference in indoor radon concentration by floor level, the measurement generation was vertically distributed. A comparative analysis by level was performed through the average and measured values of indoor radon concentration in each region, and statistical analysis was performed by one-way ANOVA. The average concentrations of each level were compared based on the significance level of 0.05. As a result, the intergroup measurements were not significant at all site and total(p>0.05).