http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Monosulfate ($Ca_4Al_2O_6(SO_4){\cdot}12H_2O$)의 특성 및 수중 5가 비소 제거기작 규명
김기백,심재호,최원호,박주양,Kim, K.B.,Shim, J.H.,Choi, W.H.,Park, J.Y. 대한상하수도학회 2012 상하수도학회지 Vol.26 No.1
Experiments for As(V) removal using synthesized $Ca{\cdot}Al$-monosulfate was performed from the water contaminated with arsenate. Monosulfate is known as LDHs (Layered Double Hydroxides) which is one of the anionic clay minerals. Monosulfate was synthesized mixing $C_3A$ (tricalcium aluminate), gypsum (calcium sulfate), and water with an intercalation method. The product form the synthesis was characterized by FE-SEM, WDXRF, PXRD, and FT-IR. Experiments with different doses of monosulfate were carried out for kinetic. As a result of experiment, the concentration of As(V) was reduced from 0.67 mM to 0.19 mM (0.67mM of monosulfate) and 0.178 mM (1.34 mM of monosulfate). The concentration of sulfate was increased with As(V) decrease. The result of PXRD showed that the d-spacing of inter layer ($d_{003}$ peak) was shifted from 8.927 ${\AA}$ to 8.095 ${\AA}$ because the sulfate in the inter layer of monosulfate was exchanged arsenate with water molecules bonded. From the FT-IR results, a new single band (800 cm-1) was observed after the reaction of monosulfate and As(V). The arsenic removal can be regarded as anion exchange mechanism that is one of the characteristics of LDHs from the results of PXRD and FT-IR analysis.
온도 시험 시 항온챔버의 내부 유동이 장비에 미치는 영향
김고은(K. E. Kim),김기백(K. B. Kim),한성욱(S. W. Han),김원현(W. H. Kim) Korean Society for Precision Engineering 2021 한국정밀공학회 학술발표대회 논문집 Vol.2021 No.11월
온도시험은 온도 조건에 따라 장비 신뢰성을 검증하는 시험으로 고온 운용, 고온 저장, 저온 운용, 저온 저장 등이 있다. 일반적으로 온도시험은 설정한 온도 프로파일 조건에서 안정적으로 유지되어야 하므로 항온챔버에서 시험을 수행한다. 항온챔버는 온도 센서에서 수집한 데이터를 기반으로 온도를 조절할 수 있고 챔버 내부 공간의 열을 순환시킴으로써 온도를 균일하게 유지한다. 이때 챔버 내 공기 토출구의 유속은 10 m/s 내외로 추정되며 이는 장비고유의 방열 효과를 측정하는데 방해 요소로 작용한다. 본 논문에서는 시험을 통해 챔버 작동 시 발생하는 내부 유동이 시험 장비 온도에 미치는 영향을 검토하였다. 설정한 온도 프로파일 조건으로 챔버를 이용한 온도시험 결과와 상온 조건에서의 결과를 비교 분석하였다. 이때, 챔버 내 내부 유동의 영향을 확인하기 위해 팬 조립체를 장착한 장비와 장착하지 않은 장비를 시험 대상으로 선정하였다. 시험 대상을 비교한 결과, 챔버를 이용한 온도시험에서는 팬 조립체 유무에 따른 온도 차가 약 5℃ 이하지만 상온 조건에서는 18℃ 이상의 온도 차를 확인하였다. 상온조건에서는 팬 조립체 유무에 따른 온도 차이가 발생하지만 챔버 내에서는 내부 유동으로 인해 정확한 측정값을 도출하는데 한계가 있음을 알 수 있었다. 이로써 본 연구에서는 온도시험을 통해 장비의 방열 효과를 검증할 경우 챔버 내 내부 유동을 고려해야 함을 확인하였다.
기능성 소화불량증 환자의 위배출시간에 따른 위전도 ( EGG ) 에 관한 연구
박영숙(Y . S . Park),김영수(Y . S . Kim),강한걸(H . G . Kang),함기백(K . B . Hahm),김진홍(J . H . Kim),조성원(S . W . Cho),이상인(S . I . Lee),김옥화(O . H . Kim) 대한내과학회 1996 대한내과학회지 Vol.50 No.6
N/A Objectives The aim of this study was to know the clinical significance of electrogastrography(EGG) and to determine the relationship between gastric myoelectrical activity and gastric emptying time in patients with functional dyspepsia. Methods: This study included 10normal subjects and 30patients with functional dyspepsia. They were given scrambled egg with 2mCi 99m Tc-sulfur colloid for measuring gastric emptying time. We measured half time(T1/2) and remnant radio activity at 2hour after meal. Gastric myoelectrical activity was recorded by cutaneous EGG(Synetics, Digitrapper EGG) in 30patients with functional dyspepsia. EGG was recorded for at least 30minutes in fasting state and 30minutes in post prandial state (solid test meal, 618Cal), EGG was analyzed based on the running power spectra. Results: 1) In 10 normal subjects, the mean of gastric emptying time (Tl/2) was 89.0±7.9min and among 30 patients of functional dyspepsia, 14patients (46%) showed delayed GET (delayed GET group) and 16patients (53%) showed normal GET (normal GET grooup) 2) In both patients group, there was no significant difference in the percentage of normal gastric slow waves(2-4cpm) between fasting state and post prandial state. 3) In post prandial state, the ratio of slow wave in normal GET group was significantly higher than that in delayed GET group (95.5±6.2% vs 82.5±14.3%, p<0.05), but in fasting state, there was no significant difference. 4) Normal post prandial amplitude increment (1.5times higher than fasting state amplitude) was seen in 7(50%)cases of delayed GET group and in 13(80%)cases of normal GET gorup, which was statistically significant (p<0.05). Conclusion: Among patients with functional dyspepsia, delayed GET group showed higher ratio of gastric dysrhythmia and abnormal post prandial amplitude change. Electrogastrography seems to have clinical significance in evaluating the explanable cause of functional dyspepsia.