http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김상은,손영찬,정철용,구순본 대한골절학회 1998 대한골절학회지 Vol.11 No.4
The importance of residual angular deformity after tibial fracture is still uncertain. But it is generally assumed that osteoarthritis of the ankle and the knee will result when the deformity is severe. Therefore accurate measurement of the alignment of the tibia is important clinically and in research. We compared the results of conventional methods (method 1,2) of measuring the angulation deformity after a fracture of the shaft of the tibia, with a new method using mechanical axis reported by Milner ' (method 3). Sixty-seven patients of tibial fractures with angulation deformity treated at Sei Gang General Hospital from January 1995 to December 1996 were evaluated. Samples of 20 sets of standard AP and lateral radiographs of both tibia were measured. The results obtained were as followc. 1. The difference between the angles obtained by Milner s new method (method 3) and conventional methods (method I, 2) was cignificant in all planes. 2. Both the mean intra- & interohserver difference were minimal in new method, compared with conventional methods, at all planes. 3. There is no statistically significant difference using by paired T-test between angles obtained by new method and conventional methods (p$gt;0.05). From these results, an angulation of measuring the new method was accurate and has good inter-and intraobserver reliability.