      • KCI등재

        Current Status of Serum Insulin and C-Peptide Measurement in Clinical Laboratories: Experience from 94 Laboratories in China

        Zhou Weiyan,Deng Yuhang,Zhao Haijian,Zhang Chuanbao 대한진단검사의학회 2022 Annals of Laboratory Medicine Vol.42 No.4

        Background: Accurate measurements of serum insulin and C-peptide are needed for the therapy and classification of diabetes. This study investigated the status of serum insulin and C-peptide measurements in China by analyzing the results of five pooled serum samples measured in 94 laboratories. Methods: Patient serum samples were pooled into five groups according to insulin and C-peptide concentrations and measured in 94 laboratories using different measurement systems. The inter- and intra-laboratory %CV as well as inter- and intra-measurement system %CV were calculated to assess the status of insulin and C-peptide measurements. To verify whether the disagreement between laboratories was due to different calibrators, as reported in previous studies, one low-level and one high-level sample extracted from the five pooled serum samples were used to recalibrate clinical measurement systems. Results: The mean intra-laboratory, intra-measurement system, inter-laboratory, and inter-measurement system %CVs were 2.7%, 4.8%, 21.8%, and 22.4%, respectively, for insulin and 2.3%, 6.7%, 16.4%, and 24.5%, respectively, for C-peptide. The inter- and intra-laboratory %CVs for insulin decreased with increasing concentration. After recalibration with low- and high-level samples, the mean inter-measurement %CV decreased from 22.4% to 17.2% for insulin and from 24.5% to 5.7% for C-peptide. Conclusions: The intra-laboratory and intra-measurement system imprecision values are satisfactory for serum insulin and C-peptide measurements. However, the results from laboratories using different measurement systems were not comparable, and there is still much work needed to achieve the standardization or harmonization of serum insulin and C-peptide measurements.

      • KCI등재

        TGF-β1/IL-11/MEK/ERK signaling mediates senescence-associated pulmonary fibrosis in a stress-induced premature senescence model of Bmi-1 deficiency

        Haiyun Chen,Jialong Liang,Xin Gu,Jiawen Zhou,Chunfeng Xie,Xianhui Lv,Rong Wang,Qing Liu,Zhiyuan Mao,Haijian Sun,Guoping Zuo,Dengshun Miao,Jianliang Jin 생화학분자생물학회 2020 Experimental and molecular medicine Vol.52 No.-

        To study whether TGF-β1/IL-11/MEK/ERK (TIME) signaling mediates senescence-associated pulmonary fibrosis (SAPF) in Bmi-1-deficient (Bmi-1−/−) mice and determines the major downstream mediator of Bmi-1 and crosstalk between p16INK4a and reactive oxygen species that regulates SAPF, phenotypes were compared among 7-week-old p16INK4a and Bmi-1 double-knockout, N-acetylcysteine (NAC)-treated Bmi-1−/−, Bmi-1−/−, and wild-type mice. Pulmonary fibroblasts and alveolar type II epithelial (AT2) cells were used for experiments. Human pulmonary tissues were tested for type Ι collagen, α-smooth muscle actin (α-SMA), p16INK4a, p53, p21, and TIME signaling by using enzyme-linked immunosorbent assay (ELISA). Our results demonstrated that Bmi-1 deficiency resulted in a shortened lifespan, ventilatory resistance, poor ventilatory compliance, and SAPF, including cell senescence, DNA damage, a senescence-associated secretory phenotype and collagen overdeposition that was mediated by the upregulation of TIME signaling. The signaling stimulated cell senescence, senescence-related secretion of TGF-β1 and IL-11 and production of collagen 1 by pulmonary fibroblasts and the epithelial-to-mesenchymal transition of AT2 cells. These processes were inhibited by anti-IL-11 or the MEK inhibitor PD98059. NAC treatment prolonged the lifespan and ameliorated pulmonary dysfunction and SAPF by downregulating TIME signaling more than p16INK4a deletion by inhibiting oxidative stress and DNA damage and promoting ubiquitinproteasome degradation of p16INK4a and p53. Cytoplasmic p16INK4a accumulation upregulated MEK/ERK signaling by inhibiting the translocation of pERK1/2 (Thr202/Tyr204) from the cytoplasm to the nucleus in senescent fibroblasts. The accumulation of collagen 1 and α-SMA in human lungs accompanied by cell senescence may be mediated by TIME signaling. Thus, this signaling in aging fibroblasts or AT2 cells could be a therapeutic target for preventing SAPF.

      • KCI등재

        Commutability Assessment of Processed Human Plasma Samples for Normetanephrine and Metanephrine Measurements Based on the Candidate Reference Measurement Procedure

        Deng Yuhang,Liu Qingxiang,Liu Zhenni,Zhao Haijian,Zhou Weiyan,Zhang Chuanbao 대한진단검사의학회 2022 Annals of Laboratory Medicine Vol.42 No.5

        Background: To identify candidate external quality assessment (EQA) materials for normetanephrine and metanephrine measurements, we assessed the commutability of eight processed human plasma samples. The agreement between routine assays and the candidate reference measurement procedure (cRMP) was also evaluated. Methods: Fifty-three clinical samples and eight processed plasma samples were prepared. The processed samples included pooled and individual plasma samples spiked with pure normetanephrine and metanephrine and non-spiked pooled and individual plasma samples. The clinical and processed samples were subjected to four routine isotope dilution tandem mass spectrometry assays and cRMP. Commutability was assessed based on two approaches recommended by the CLSI and International Federation of Clinical Chemistry (IFCC). Passing–Bablok regression and Bland–Altman analysis were used to evaluate the agreement between the routine assays and cRMP. Results: The commutability results of the CLSI approach were better than those of the IFCC approach. For the CLSI approach, spiked individual plasma samples and spiked high-concentration pooled plasma samples were commutable for all routine assays for both analytes. The non-spiked pooled plasma sample was commutable for two out of four routine assays for metanephrine and three out of four routine assays for normetanephrine. The agreement between the routine assays and the cRMP was satisfactory, except for one routine assay showing significant bias. Conclusions: High-concentration spiked pooled plasma samples and spiked individual plasma samples are candidate EQA materials for normetanephrine and metanephrine measurements.

      • SCOPUSKCI등재

        Association of multiple anthropometric indices with in 944,760 elderly Chinese people

        Lirong Dong,Yuanyuan Wang,Jinshui Xu,Yang Zhou,Guiju Sun,Dakang Ji,Haijian Guo,Baoli Zhu 한국역학회 2023 Epidemiology and Health Vol.45 No.-

        OBJECTIVES: The aims of this study were to update the latest data on the prevalence of hypertension (HTN) in the elderly Chinese population and to assess relationships between new anthropometric indices and HTN. METHODS: Data were obtained from the Basic Public Health Service (BPHS) survey for Jiangsu Province, China. A total of 944,760 people aged 65 years and older were included in this study. Blood pressure was measured by trained investigators. Body weight, body mass index (BMI), waist circumference (WC), waist-to-height ratio (WtHR), conicity index (COI), body roundness index (BRI), and a body shape index (ABSI) were included in the analysis as anthropometric indices. Logistic regression analysis and restricted cubic splines were used to evaluate the association of anthropometric indices with HTN. RESULTS: The prevalence of HTN among elderly residents of Jiangsu Province was 64.7% (95% confidence interval, 64.6 to 64.8). After adjusting for multiple covariates, all anthropometric indices except ABSI showed significant non-linear positive dose-response associations with HTN across sex (pnonlinear<0.001). Among participants with BMI <28 kg/m2, abnormal weight, WC, WtHR, BRI, COI, and ABSI were positively associated with HTN. CONCLUSIONS: The prevalence of HTN in the elderly in Jiangsu Province is gradually increasing. It is necessary to consider the combination of ABSI and COI with BMI for screening elderly individuals for HTN in follow-up prospective studies.

      • KCI등재
      • KCI등재

        An Accurate Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry Method for Serum C-Peptide and Its Use in Harmonization in China

        Deng Yuhang,Zhang Chao,Wang Jing,Zeng Jie,Zhang Jiangtao,Zhang Tianjiao,Zhao Haijian,Zhou Weiyan,Zhang Chuanbao 대한진단검사의학회 2023 Annals of Laboratory Medicine Vol.43 No.4

        Background: Serum C-peptide results from various routine methods used in China are highly variable, warranting well-performing methods to serve as an accuracy base to improve the harmonization of C-peptide measurements in China. We developed an accurate isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC–MS/MS) method for serum C-peptide measurement and explored its use in harmonization. Methods: After protein precipitation with ZnSO4 solution, C-peptide was extracted from serum samples by anion-exchange solid-phase extraction and quantified by ID-LC–MS/MS in positive ion mode. The precision and analytical recovery of the ID-LC–MS/MS method were assessed. Seventy-six serum samples were analyzed using the ID-LC–MS/MS method and six routine immunoassays. Ordinary linear regression (OLR) and Bland-Altman (BA) analyses were conducted to evaluate the relationship between the ID-LC–MS/MS method and routine immunoassays. Five serum pool samples assigned using the ID-LC–MS/MS method were used to recalibrate the routine assays. OLR and BA analyses were re-conducted after recalibration. Results: The within-run, between-run, and total precision for the ID-LC–MS/MS method at four concentrations were 1.0%–2.1%, 0.6%–1.2%, and 1.3%–2.2%, respectively. The analytical recoveries for the ID-LC–MS/MS method at three concentrations were 100.3%–100.7%, 100.4%–101.0%, and 99.6%–100.7%. The developed method and the immunoassays were strongly correlated, with all R2 >0.98. The comparability among the immunoassays was substantially improved after recalibration. Conclusions: The performance of the ID-LC–MS/MS method was carefully validated, and this method can be used to improve the harmonization of serum C-peptide measurements in China.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료