Aims: Late recurrence (> 2 years) after liver resection of hepatocellular carcinoma (HCC) is usually considered as multi-centric tumors or de novo cancer formation. We aimed to investigate risk factors, patterns and outcomes of late recurrence after HCC resection. Methods: From a multicenter database from 2001 to 2015, 734 patients who were alive and recurrence-free at 2 years after curative resection of initial HCC were enrolled into this retrospective study. Univariate and multivariate Cox-regression analysis were used to identify independent risk factors of late recurrence. Patterns, treatments and outcomes of late recurrence were investigated and analyzed. Results: During a median follow-up of 78.0 months after surgery, 303 patients (41.3%) developed late recurrence. Multivariate analysis revealed that cirrhosis, macroscopic vascular invasion, satellites, and tumor size > 5cm were independent risk factors of late recurrence. Among them, 273 (90.1%) were sole intrahepatic recurrence, 30 (9.9%) were concurrent intrahepatic and extrahepatic recurrence, and none of them was sole extrahepatic recurrence; 165 (54.4%) patients received curative treatments for recurrent HCC, including re-resection, transplantation and local ablation. Multivariate analysis showed regular postoperative surveillance and receiving curative treatments were two independent protective factors of prolonging survival for those patients with late recurrence. Conclusions: Late recurrence is correlated with cirrhosis and certain tumor-related characteristics of initial HCC. The patterns of late recurrence suggest that postoperative surveillance after 2 years of surgery could be adjusted and more targeted. Regular postoperative surveillance improves the probability to receive curative treatments again, yielding to better outcomes for patients with late recurrence.
Hai-Zhen Wang,Xin Zhong,Gu-Ren Zhang,Xin Liu,Li Gu 한국응용곤충학회 2020 Journal of Asia-Pacific Entomology Vol.23 No.2
Gynaephora qinghaiensis is a pest on the Qinghai-Tibet Plateau (QTP) that has led to substantial destruction of grassland vegetation. Its pupae are also natural hosts of parasitic wasp. Sexual dimorphism in immune responses is prevalent in vertebrates and invertebrates. However, sexual dimorphism in immune responses of insects, particularly G. qinghaiensis, is poorly understood at the transcriptional level. Here, we performed transcriptome sequencing in male and female pupae of G. qinghaiensis. A total of 118,357,040 clean reads were obtained and assembled into 114,944 unigenes. To explore the difference of immune responses in pupae of both sexes (male and female) of G. qinghaiensis. based on transcriptional level, we characterized the expression profiles of candidate transcripts in the two sexes of G. qinghaiensis. A total of 3,469 unigenes (1,888 up-regulated and 1,581 down-regulated genes) were differentially expressed in pupae of both sexes. Among the differentially expressed genes (DEGs), 263 unigenes related to immune responses were found in the two sexes in G. qinghaiensis; of these, 202 were up-regulated and 61 were down-regulated in the female pupae compared to male pupae. This indicates there were some differences in the expression of immune-related genes between male and female G. qinghaiensis pupae. Therefore, we speculated that the differences in immune responses also likely exsited in pupae of both sexes. Our report provides a valuable genomic resource for further studies of Gynaephora and improves our understanding of the molecular mechanisms underlying immunological differences between male and female insects.
A 3-D Steady-State Analysis of Thermal Behavior in EHV GIS Busbar
Lei, Jin,Zhong, Jian-ying,Wu, Shi-jin,Wang, Zhen,Guo, Yu-jing,Qin, Xin-yan The Korean Institute of Electrical Engineers 2016 Journal of Electrical Engineering & Technology Vol.11 No.3
Busbar has been used as electric conductor within extra high voltage (EHV) gas insulated switchgear (GIS), which makes EHV GIS higher security, smaller size and lower cost. However, the main fault of GIS is overheating of busbar connection parts, circuit breaker and isolating switch contact parts, which has been already restricting development of GIS to a large extent. In this study, a coupled magneto-flow-thermal analysis is used to investigate the thermal properties of GIS busbar in steady-state. A three-dimensional (3-D) finite element model (FEM) is built to calculate multiphysics fields including electromagnetic field, flow field and thermal field in steady-state. The influences of current on the magnetic flux density, flow velocity and heat distribution has been investigated. Temperature differences of inner wall and outer wall are investigated for busbar tank and conducting rod. Considering the end effect in the busbar, temperature rise difference is compared between end sections and the middle section. In order to obtain better heat dissipation effect, diameters of conductor and tank are optimized based on temperature rise simulation results. Temperature rise tests have been done to validate the 3-D simulation model, which is observed a good correlation with the simulation results. This study provides technical support for optimized structure of the EHV GIS busbar.
Li, Xiang-Dan,Zhong, Zhen-Xin,Han, Sang-Hoon,Lee, Seung Hee,Lee, Myong-Hoon John Wiley Sons, Ltd. 2005 Polymer international Vol.54 No.2
<P>From chloromethylated polyimide, a useful starting material for modification of aromatic polyimides, a thermocurable transparent polyimide having acrylate side groups was prepared. In the presence of 1,8-diazabicyclo[5,4,0]undec-7-ene, chloromethylated polyimide was esterified with acrylic acid to synthesize poly(imide methylene acrylate). The polymer was soluble in organic solvent, which makes it possible to prepare a planar film by spin coating. The polymer film became insoluble after thermal treatment at 230 °C for 30 min. Optical transparency of the film at 400 nm (for 1 µm thickness) was higher than 98 % and not affected by further heating at 230 °C for 250 min. Adhesion properties measured by the ASTM D3359-B method ranged from 4B to 5B. Preliminary results of planarization testing showed a high degree of planarization (DOP) value (>0.53). These properties demonstrate that poly(imide methylene acrylate) could be utilized as a thermocurable transparent material in fabricating display devices such as TFT-LCD. Copyright © 2004 Society of Chemical Industry</P>
A 3-D Steady-State Analysis of Thermal Behavior in EHV GIS Busbar
Jin Lei,Jian-ying Zhong,Shi-jin Wu,Zhen Wang,Yu-jing Guo,Xin-yan Qin 대한전기학회 2016 Journal of Electrical Engineering & Technology Vol.11 No.3
Busbar has been used as electric conductor within extra high voltage (EHV) gas insulated switchgear (GIS), which makes EHV GIS higher security, smaller size and lower cost. However, the main fault of GIS is overheating of busbar connection parts, circuit breaker and isolating switch contact parts, which has been already restricting development of GIS to a large extent. In this study, a coupled magneto-flow-thermal analysis is used to investigate the thermal properties of GIS busbar in steady-state. A three-dimensional (3-D) finite element model (FEM) is built to calculate multiphysics fields including electromagnetic field, flow field and thermal field in steady-state. The influences of current on the magnetic flux density, flow velocity and heat distribution has been investigated. Temperature differences of inner wall and outer wall are investigated for busbar tank and conducting rod. Considering the end effect in the busbar, temperature rise difference is compared between end sections and the middle section. In order to obtain better heat dissipation effect, diameters of conductor and tank are optimized based on temperature rise simulation results. Temperature rise tests have been done to validate the 3-D simulation model, which is observed a good correlation with the simulation results. This study provides technical support for optimized structure of the EHV GIS busbar.