http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Fabrication and Performance of X-ray tube with CNT based Electron Beam (C-beam)
Yi Yin Yu,Kyu Chang Park 한국진공학회 2021 한국진공학회 학술발표회초록집 Vol.2021 No.2
Modern x-ray imaging techniques require more finer resolution and dose reduction for early diagnosis of diseases and safety regulation respectively. Currently available x-ray sources are based on thermionic electron emitters which emit electron when they are heated over 2000 K. Therefore, the emitters are susceptible to oxidation and it degrades x-ray tube lifespan. In addition, the emitted electron beam has wide beam divergence hence, additional electrodes are required to focus the beam on anode target. Besides fast switching of x-ray radiation from thermionic emitters is impossible due to its inherent electron emission mechanism. Field emission phenomena and the principles are intensively studied due to the its extraordinary electrical properties. Among them, vertically align carbon nanotubes (VACNTs) are prominent cold cathode candidates owing to their ballast electron transport characteristics and free-standing structure which is easy to maximize electric field strength to the emitters. The authors report on triode configuration e-beam module fabrication process and their electrical characteristics for the purpose of x-ray tube applications. Furthermore, a reflection type of glass sealed x-ray tube also fabricated with our c-beam module. The tube properties such as 1-V curves, dose rate and focal spot size were evaluated and compared to that of conventional thermionic one. The authors believe that our cold cathode employed x-ray tubes are viable for high resolution medical imaging and dose reduction thanks to their narrow beam divergence and capability of instantaneous switching respectively.
Yu-Li Chen,Kung-Liahng Wang,Min-Yu Chen,Mu-Hsien Yu,Chen-Hsuan Wu,Yu-Min Ke,Yi-Jen Chen,Yin-Yi Chang,Keng-Fu Hsu,Ming-Shyen Yen 대한부인종양학회 2013 Journal of Gynecologic Oncology Vol.24 No.1
Objective: To evaluate the clinical outcome and parameters related to coexisting endometrial carcinoma in women with tissuediagnosed endometrial hyperplasia. Methods: Between January 1991 and December 2009, three hundred and eighty-six patients with the presumptive diagnosis of endometrial hyperplasia were retrieved. Among these, one hundred and twenty-five patients were identified as having coexisting endometrial carcinoma in hysterectomy specimens. The three hundred and eighty-six patients were divided into two groups: the hyperplasia-benign group (261 cases) and the hyperplasia-malignant group (125 cases). Several clinical parameters including age, menopausal status, history of abnormal uterine bleeding, obstetrical history, medical history of diabetes and hypertension, BMI, and preoperative pathologic results were investigated. Results: Age ≥53 (odds ratio [OR], 2.40; 95% confidence interval [CI], 1.26 to 4.57), menopausal status (OR, 2.07; 95% CI, 1.14to 3.76), diabetes history (OR, 7.33; 95% CI, 2.79 to 19.26), abnormal uterine bleeding (OR, 3.99; 95% CI, 1.22 to 13.02), atypical endometrial hyperplasia (OR, 7.38; 95% CI, 4.03 to 13.49), and body mass index ≥27 (OR, 3.24; 95% CI, 1.76 to 5.97) were independent risk factors for prediction of endometrial hyperplasia coexisting with endometrial carcinoma. The diagnostic efficacy of atypical endometrial hyperplasia to predict the endometrial hyperplasia coexisting with endometrial carcinoma was better than or similar to those of other independent factors and combinations of these factors. Conclusion: Coexisting malignancy should be considered when examining endometrial hyperplasia patients with the related risk factors, especially atypical endometrial hyperplasia.
( Wen Yu Zhao ),( Jun Yi Yu ),( Yin Hu Wu ),( Yu Hong ),( Hong Ying Hu ) 한국미생물생명공학회(구 한국산업미생물학회) 2014 한국미생물·생명공학회지 Vol.42 No.2
While coupling wastewater treatment with microalgal bioenergy production is very promising, new approaches are needed to enhance microalgal growth and lipid accumulation in wastewater. Therefore, this study investigated the effect of iron on the growth, nutrient removal, and lipid accumulation of Scenedesmus sp. LX1 in both artificial wastewater and domestic secondary effluents. When increasing the iron concentration from 0 to 2 mg/l in the artificial wastewater, the biomass production of Scenedesmus sp. LX1 increased from 0.17 to 0.54 g/l; the nitrogen and phosphorus removal efficiency increased from 15.7% and 80.6% to 97.0% and 99.2%, respectively; and the lipid content was enhanced 84.2%. The relationship between the carrying capacity/maximal population growth rate of Scenedesmus sp. LX1 and the initial iron concentration were also in accordance with the Monod model. Furthermore, when increasing the iron concentration to 2 mg/l in four different domestic secondary effluent samples, the lipid content and lipid production of Scenedesmus sp. LX1 was improved by 17.4-33.7% and 21.5-41.8%, respectively.
Zhao, Wen-Yu,Yu, Jun-Yi,Wu, Yin-Hu,Hong, Yu,Hu, Hong-Ying The Korean Society for Microbiology and Biotechnol 2014 한국미생물·생명공학회지 Vol.42 No.2
While coupling wastewater treatment with microalgal bioenergy production is very promising, new approaches are needed to enhance microalgal growth and lipid accumulation in wastewater. Therefore, this study investigated the effect of iron on the growth, nutrient removal, and lipid accumulation of Scenedesmus sp. LX1 in both artificial wastewater and domestic secondary effluents. When increasing the iron concentration from 0 to 2 mg/l in the artificial wastewater, the biomass production of Scenedesmus sp. LX1 increased from 0.17 to 0.54 g/l; the nitrogen and phosphorus removal efficiency increased from 15.7% and 80.6% to 97.0% and 99.2%, respectively; and the lipid content was enhanced 84.2%. The relationship between the carrying capacity/maximal population growth rate of Scenedesmus sp. LX1 and the initial iron concentration were also in accordance with the Monod model. Furthermore, when increasing the iron concentration to 2 mg/l in four different domestic secondary effluent samples, the lipid content and lipid production of Scenedesmus sp. LX1 was improved by 17.4-33.7% and 21.5-41.8%, respectively.
Hung-Chun Fu,Jen-Ruei Chen,Min-Yu Chen,Keng-Fu Hsu,Wen-Fang Cheng,An Jen Chiang,Yu-Min Ke,Yu-Chieh Chen,Yin-Yi Chang,Chia-Yen Huang,Chieh-Yi Kang,Yuan-Yee Kan,Sheng-Mou Hsiao,Ming-Shyen Yen 대한부인종양학회 2018 Journal of Gynecologic Oncology Vol.29 No.5
Objective: Choice of hysterectomy and adjuvant treatment for International Federation of Gynecology and Obstetrics (FIGO) 2009 stage II endometrioid endometrial cancer (EEC) is still controversial. Aims of this study were to evaluate survival benefits and adverse effects of different hysterectomies with or without adjuvant radiotherapy (RT), and to identify prognostic factors. Methods: The patients at 14 member hospitals of the Taiwanese Gynecologic Oncology Group from 1992 to 2013 were retrospectively investigated. Patients were divided into simple hysterectomy (SH) alone, SH with RT, radical hysterectomy (RH) alone, and RH with RT groups. Endpoints were recurrence-free survival (RFS), overall survival (OS), disease-specific survival (DSS), adverse effects and prognostic factors for survival. Results: Total of 246 patients were enrolled. The 5-year RFS, OS, DSS and recurrence rates for the entire cohort were 89.5%, 94.3%, 96.2% and 10.2%, respectively. Patients receiving RH had more adverse effects including blood loss (p<0.001), recurrent urinary tract infections (p=0.013), and leg lymphedema (p=0.038). Age over 50-year (HR=9.2; 95% confidence interval [CI], 1.2–70.9) and grade 3 histology (HR=7.28; 95% CI, 1.45–36.6) were independent predictors of OS. Grade 3 histology was an independent predictor of RFS (HR=5.13; 95% CI, 1.38–19.1) and DSS (HR=5.97; 95% CI, 1.06–58.7). Patients receiving adjuvant RT had lower locoregional recurrence (p=0.046), but no impact on survival. Conclusion: Different treatment modalities yield similar survival outcomes. Patients receiving SH with RT had lower locoregional recurrent with acceptable morbidity. Age and tumor grading remained significant predictors for survival among patients with FIGO 2009 stage II EEC.
Blind QR Code Steganographic Approach Based upon Error Correction Capability
( Yin-jen Chiang ),( Pei-yu Lin ),( Ran-zan Wang ),( Yi-hui Chen ) 한국인터넷정보학회 2013 KSII Transactions on Internet and Information Syst Vol.7 No.10
A novel steganographic QR code algorithm, which not only coveys the secret into the widely-used QR barcode but also preserves the readability of QR content and the capability of error correction, is presented in this article. Different from the conventional applications for QR barcode, the designed algorithm conceals the secret into the QR modules directly by exploiting the error correction capability. General browsers can read the QR content from the QR code via barcode readers; however, only the authorized receiver can further reveal the secret from the QR code directly. The new mechanism can convey a larger secret payload along with adjustment of the QR version and error correction level. Moreover, the blind property allows the receiver to reveal the secret without the knowledge of the embedded position of modules. Experimental results demonstrate that the new algorithm is secure, efficient and feasible for the low-power QR readers and mobile devices.
( Shang Yu Wang ),( Chun Nan Yeh ),( Yi Yin Jan ),( Miin Fu Chen ) 대한소화기기능성질환·운동학회(구 대한소화관운동학회) 2021 Gut and Liver Vol.15 No.4
Acute cholecystitis and several gallbladder stone-related conditions, such as impacted common bile duct stones, cholangitis, and biliary pancreatitis, are common medical conditions in daily practice. An early cholecystectomy or drainage procedure with delayed cholecystectomy is the current standard of treatment based on published clinical guidelines. Cirrhosis is not only a condition of chronically impaired hepatic function but also has systemic effects in patients. In cirrhotic individuals, several predisposing factors, including changes in the bile acid composition, increased nucleation of bile, and decreased motility of the gallbladder, contribute to the formation of biliary stones and the possibility of symptomatic cholelithiasis, which is an indication for surgical treatment. In addition to these predisposing factors for cholelithiasis, systemic effects and local anatomic consequences related to cirrhosis lead to anesthesiologic risks and perioperative complications in cirrhotic patients. Therefore, the treatment of the aforementioned biliary conditions in cirrhotic patients has become a challenging issue. In this review, we focus on cholecystectomy for cirrhotic patients and summarize the surgical indications, risk stratification, surgical procedures, and surgical outcomes specific to cirrhotic patients with symptomatic cholelithiasis. (Gut Liver 2021;15:517-527)
Huang, Yin-Jiu,Zhang, Yu-Yuan,Liu, Gang,Tang, Jie,Hu, Jian-Guo,Feng, Zhen-Zhong,Liu, Fang,Wang, Qi-Yi,Li, Dan Asian Pacific Journal of Cancer Prevention 2014 Asian Pacific journal of cancer prevention Vol.15 No.15
Cervical cancer is one the most common malignancies among females. In recent years, its incidence rate has shown a rising trend in some countries so that development of anticancer drugs for cervical cancer is an urgent priority. In our recent anticancer drug discovery screen, 1, 2-di (quinazolin-4-yl)diselane (LG003) was found to possess wide spectrum anticancer efficacy. In the present work, the in vitro anticancer activity of LG003 was evaluated in the SiHa cervical cancer cell line. Compared with commercial anticancer drugs 10-hydroxycamptothecin, epirubicin hydrochloride, taxol and oxaliplatin, LG003 showed better anticancer activity. Furthermore, inhibition effects were time- and dose-dependent. Morphological observation exhibited LG003 treatment results in apoptosis like shrinking and blebbing, and cell membrane damage. Lactate dehydrogenase release assay revealed that LG003 exerts such effects in SiHa cells through a physiology pathway rather than cytotoxicity, which suggests that title compound LG003 can be a potential candidate agent for cervical cancer.
Growth of Vertically Aligned CNTs with Ultra Thin Ni Catalysts
유제황,Yi-Yin Yu,Chang-Seok Lee,Jin Jang,Kyu-Chang Park,Ki-Seo Kim 한국전기전자재료학회 2008 Transactions on Electrical and Electronic Material Vol.9 No.2
We report on the growth mechanism of vertically aligned carbon nanotubes (VACNTs) using ultra thin Ni catalysts and direct current plasma enhanced chemical vapor deposition (PECVD) system. The CNTs were grown with -600 V bias to substrate electrode and catalyst thickness variation of 0.07 nm to 3 nm. The CNT density was reduced with catalyst thickness reduction and increased growth time. Cone like CNTs were grown with ultra thin Ni thickness, and it results from an etch of carbon network by reactive etchant species and continuous carbon precipitation on CNT walls. Vertically aligned sparse CNTs can be grown with ultra thin Ni catalyst.