http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Kwantae Noh,Woo-Jin Choi,Ahran Pae 대한치과보철학회 2013 The Journal of Advanced Prosthodontics Vol.5 No.1
Traumatic defects are mostly accompanied by hard and soft tissue loss. This report describes the surgical and prosthetic treatment of a patient with post-traumatic mandibular defect. A split-thickness skin graft was performed prior to implant placement and prefabricated acrylic stent was placed to hold the graft in place. The esthetic and functional demands of the patient were fulfilled by implant-supported screw-retained fixed prosthesis.
노관태(Kwantae Noh) 대한치과의사협회 2018 대한치과의사협회지 Vol.56 No.6
The mouth guard is a device with elasticity to be installed in the oral cavity. It has a function to reduce the trauma in the oral cavity and to protect the teeth and surrounding tissues from trauma. The purpose of mouth guard is to prevent trauma and concussion. It is mandatory to wear a mouthguard in sports where there is a lot of contact and the possibility of trauma or concussion in the mouth area is high. The mouse guard is divided into a stock type, a mouth formed type, and a custom made type according to the manufacturing method. The custom made type is made on the individual dentition model and has excellent retention because of its excellent fit. Also, the effect of trauma prevention is excellent. It is possible to design and adjust by the dentist and reduce the complaint the athlete has about the mouthguard. In this article, the process of making a dentist-customized mouthguard was described.
노관태(Kwantae Noh) 대한치과의사협회 2020 대한치과의사협회지 Vol.58 No.9
If the implant is planted in the wrong position or direction, it is disadvantageous for stress distribution, and it is easy to cause complications such as screw loosening, abutment fracture, and implant fracture. If the position or orientation of the implant is not good, efforts should be made to minimize the problem through proper implant prosthetic treatment. In this article, the prosthetic method for facilitating future maintenance in cases with poor implant placement or orientation will be presented
Biofunctional Prosthetic System(BPS) 를 이용한 심미 총의치 제작
노관태,Noh, Kwantae 대한심미치과학회 2015 Journal of the Korean Academy of Esthetic Dentistr Vol.24 No.1
최근 건강한 고령 무치악자가 증가하면서 높은 기능과 심미성을 갖춘 의치에 대한 요구가 증가하고 있다. BPS(Biofunctional Prosthetic System)는 현재 미국, 일본의 많은 학교에서 교육과정에 도입하고 있으며, 각 단계가 표준화, 시스템화 되어있어 의치제작 경험이 비교적 적은 술자도 만족도 높은 의치를 제작할 수 있는 시스템이다. 또한 이 BPS의 치 제작법에 하악 총의치의 흡착 메커니즘을 융합하면 기능시 안정된 하악의치를 제작할 수 있다. 본고에서는 BPS와 하악총의치 흡착 인상법을 이용하여 기능시 안정되고 심미성이 뛰어난 의치를 제작하는 과정을 기술하고자 한다. The growing of healthy aged edentulous peoples in these days increases the demands of denture which is excellent in function and aesthetic. The Biofunctional Prosthetic System(BPS) is being introduced as a curriculum in a large number of schools in the United States, Europe and Japan. Each stages of BPS are standardized and systematized, on this account BPS is the system that even less experienced clinicians is able to produce highly satisfactory denture for patients. Additionally, the combination of BPS and suction mechanism of mandibular complete denture would make it possible to produce stabilized mandibular denture during oral function. The purpose of this article is to describe a process of producing fuctionally and aesthetically outstanding denture by using BPS combined with mandibular suction mechanism.
Lee, Hyeonjong,Noh, Kwantae,Lee, Deok-Won Korean Academy of Dental Science 2016 Journal of korean dental science Vol.9 No.2
Purpose: Alveolar bone develops with tooth eruption and is absorbed following tooth extraction. Various ridge preservation techniques have sought to prevent ridge atrophy, with no superior technique evident. Collagen has a long history as a biocompatible material. Its usefulness and safety have been amply verified. The related compound, atelocollagen, is also safe and displays reduced antigenicity since telopeptides are not present. Materials and Methods: The current study evaluated whether the $Rapiderm^{(R)}$ atelocollagen plug (Dalim Tissen, Seoul, Korea) improves tissue healing of extraction sockets and assessed the sequential pattern of bone regeneration using histology and microcomputed tomography in six beagle dogs. To assess the change of extraction socket, hard tissues were examined 2, 4, 6, and 8 weeks after tooth extraction. Result: The experimental groups showed better bone fill with slow remodeling process compared to the control groups although there was no statistical difference between groups. Conclusion: The atelocollagen seems to have a tendency to slow bone remodeling in the early phase of healing period and maintain remodeling capacity until late phase of remodeling. Also, use of atelocollagen increased the bone-to-tissue ratio compared to healing of untreated extraction socket.
Prosthetic management of a growing patient with Russell-Silver syndrome: a clinical report
Kanghyun Kim,Kwantae Noh,Janghyun Paek,Kung-Rock Kwon,Ahran Pae 대한치과보철학회 2015 The Journal of Advanced Prosthodontics Vol.7 No.5
Russell-Silver syndrome (RSS) is a congenital disease characterized by short stature due to growth hormone deficiency, physical asymmetry, inverted triangular face, micrognathia, prominent forehead, and hypodontia. This case report presents a prosthetic management of a 6-year-old patient with Russell-Silver syndrome treated with overdentures on the maxilla and the mandible using the remaining primary teeth. Subsequent and comprehensive dental management considering the growth and development of a young patient will be necessary.
Paek, Janghyun,Noh, Kwantae,Pae, Ahran,Lee, Hyeonjong,Kim, Hyeong-Seob The Korean Academy of Prosthodonitics 2016 The Journal of Advanced Prosthodontics Vol.8 No.4
Fabricating a surveyed prosthesis beneath an existing partial removable dental prosthesis (PRDP) is a challenging and time-consuming procedure. The computer-aided design/computer-assisted manufacturing (CAD/CAM) technology was applied to fabricate a retrofitted, surveyed zirconia prosthesis to an existing PRDP. CAD/CAM technology enabled precise and easy replication of the contour of the planned surveyed crown on the existing abutment tooth. This technology ensured excellent adaptation and fit of newly fabricated crown to the existing PRDP with minimal adjustments. In this case report, a seventy-year-old male patient presented with fractured existing surveyed crown. Because the existing PRDP was serviceable, new crown was fabricated to the existing PRDP.
Janghyun Paek,Kwantae Noh,Ahran Pae,Hyeonjong Lee,Hyeong-Seob Kim 대한치과보철학회 2016 The Journal of Advanced Prosthodontics Vol.8 No.4
Fabricating a surveyed prosthesis beneath an existing partial removable dental prosthesis (PRDP) is a challenging and time-consuming procedure. The computer-aided design/computer-assisted manufacturing (CAD/CAM) technology was applied to fabricate a retrofitted, surveyed zirconia prosthesis to an existing PRDP. CAD/CAM technology enabled precise and easy replication of the contour of the planned surveyed crown on the existing abutment tooth. This technology ensured excellent adaptation and fit of newly fabricated crown to the existing PRDP with minimal adjustments. In this case report, a seventy-year-old male patient presented with fractured existing surveyed crown. Because the existing PRDP was serviceable, new crown was fabricated to the existing PRDP.