http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
N. Matsuda,Y. Kasugai,Y. Sakamoto,H. Nakashima,H. Matsumura,H. Iwase,N. Kinoshitay,H. Hirayama,H. Yashima,N. Mokhov,A. Levering,D. Boehnlein,K. Vazili,L. Gary,S. Wayne,K. Oishi,T. Nakamura,K. Ishibash 한국물리학회 2011 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.59 No.23
Neutron spectra in high-energy region between 1 and 100 MeV in the shield configuration of the anti-proton target station and a 120-GeV proton beam at Fermi National Accelerator Laboratory (Fermilab) were determined using the reaction rate data obtained with the multi-foil activation method. Two kinds of methods were employed for the determination of neutron spectra: one is the fitting method which is newly developed in this work, another is the unfolding method with SAND-II code. The calculations were performed using the PHITS. From the comparison between the calculated and experimental neutron spectra, it concluded that the PHITS can be used for shielding design of highenergy proton accelerators.
Measurement of Deuteron Induced Thick Target Neutron Yields at 9 MeV
N. Shigyo,K. Hidaka,K. Hirabayashi,Y. Nakamura,D. Moriguchi,M. Kumabe,H. Hirano,S. Hirayama,Y. Naitou,C. Motooka,C. Lan,T. Watanabe,Y. Watanabe,K. Sagara,S. Maebaru,H. Sakaki,H. Takahashi 한국물리학회 2011 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.59 No.23
The double differential thick target neutron yields from 9 MeV deuteron incidence were measured at the Kyushu University Tandem Accelerator Laboratory. A copper and a titanium foils which are thick enough for a deuteron to stop in the foils were placed at the center of a vacuum chamber. An NE213 liquid organic scintillator was employed to detect neutrons emitted from targets and placed at 9 directions from 0˚ to 140˚. To consider the contribution of scattered neutrons from the floor, we also measured neutron yields with an iron shadow bar located in front of the scintillator. Because incident deuteron beam was not pulsed and the Time-of-Flight method was not applied, the energy spectrum was derived from unfolding the light output spectrum using the FORIST code. The detection efficiency was calculated with the SCINFUL-QMD code. The experimental results were compared with the calculation data of the TALYS code, and it turned out that the calculation data does not reproduce the experimental ones satisfactorily.
Shielding Experiments under JASMIN Collaboration at Fermilab (I) Overview of the Research Activities
Y. Kasugai,N. Matsuda,Y. Iwamoto,Y. Sakamoto,H. Nakashima,H. Matsumura,N. Kinoshitay,H. Iwase,T. Sanami,M. Hagiwara,H. Hirayama,H. Yashima,N. Sigyo,H. Arakawa,K. Ishibashi,N. Mokhov,A. Leveling,D. Boe 한국물리학회 2011 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.59 No.23
Shielding experiments were started on 2007 using high-energy proton accelerator at Fermi National Accelerator Laboratory (Fermilab) under the collaborative study program of JASMIN: Japanese and American Study of Muon Interaction and Neutron Detection. In this series of papers entitled "Shielding experiments under JASMIN collaboration at Fermilab", the part of the results regarding neutron detection has been reported. This paper, as a first paper of the series, overview of the research activities are described, and experimental results on high-energy neutron transportation are presented in a viewpoint of neutron attenuation in steel shield and applicability of Moyer's model. In addition, deductions of a neutron spectrum in wide energy range between 1 eV and 100 MeV by means of the hybrid method using the current-readout Bonner sphere together with foil-activation technique are presented.
Is Caffeine Intake Associated With Urinary Incontinence in Japanese Adults?
Hirayama, Fumi,Lee, Andy H. The Korean Society for Preventive Medicine 2012 Journal of Preventive Medicine and Public Health Vol.45 No.3
Objectives: To investigate whether caffeine intake is associated with urinary incontinence (UI) among Japanese adults. Methods: A total of 683 men and 298 women aged 40 to 75 years were recruited from the community in middle and southern Japan. A validated food frequency questionnaire was administered face-to-face to obtain information on dietary intake and habitual beverage consumption. Urinary incontinence status was ascertained using the International Consultation on Incontinence Questionnaire-Short Form. Results: Mean daily caffeine intake was found to be similar between incontinent subjects (men 120 mg, women 94 mg) and others without the condition (men 106 mg, women 103 mg), $p$=0.33 for men and $p$=0.44 for women. The slight increases in risk of UI at the highest level of caffeine intake were not significant after adjusting for confounding factors. The adjusted odds ratios (95% confidence interval) were 1.36 (0.65 to 2.88) and 1.12 (0.57 to 2.22) for men and women, respectively. Conclusions: No association was evident between caffeine intake and UI in middle-aged and older Japanese adults. Further studies are required to confirm the effect of caffeine in the prevention of UI.
A Study on Indicial Response Characteristics of a Gas-Lubricated Spiral-Grooved Journal Bearing
H. YABE,T. KANESHIRO,T. HIRAYAMA 한국트라이볼로지학회 2002 한국트라이볼로지학회 학술대회 Vol.2002 No.10
Indicial response characteristics of a rotor supported by a gas-lubricated, spiral-grooved journal bearing are studied theoretically to develop a fundamental investigation for the bearing design with considering NRRO characteristics. The trajectory of rotor movement is calculated by applying the non-linear orbit scheme against a prescribed impulse load, then two characteristic quantities are introduced to evaluate the indicial response performance of the bearing, i.e., "maximum deviation of rotor center" and "integrated rotor center deviation". The effects of some design parameters of spiral grooves to these representative quantities are studied so that "robust" design against impulse load is discussed.
Is Caffeine Intake Associated With Urinary Incontinence in Japanese Adults?
Fumi Hirayama,Andy H. Lee 대한예방의학회 2012 Journal of Preventive Medicine and Public Health Vol.45 No.3
Objectives: To investigate whether caffeine intake is associated with urinary incontinence (UI) among Japanese adults. Methods: A total of 683 men and 298 women aged 40 to 75 years were recruited from the community in middle and southern Japan. A validated food frequency questionnaire was administered face-to-face to obtain information on dietary intake and habitual beverage consumption. Urinary incontinence status was ascertained using the International Consultation on Incontinence Questionnaire-Short Form. Results: Mean daily caffeine intake was found to be similar between incontinent subjects (men 120 mg, women 94 mg)and others without the condition (men 106 mg, women 103 mg), p=0.33 for men and p=0.44 for women. The slight increases in risk of UI at the highest level of caffeine intake were not significant after adjusting for confounding factors. The adjusted odds ratios (95% confidence interval) were 1.36 (0.65 to 2.88) and 1.12 (0.57 to 2.22) for men and women,respectively. Conclusions: No association was evident between caffeine intake and UI in middle-aged and older Japanese adults. Further studies are required to confirm the effect of caffeine in the prevention of UI.
Association Between Green Tea Consumption and Lung Cancer Risk
Andy H. Lee,Wenbin Liang,Fumi Hirayama,Colin W.Binns 대한예방의학회 2010 Journal of Preventive Medicine and Public Health Vol.43 No.4
Green tea is a popular beverage and its health benefits are well known. However, inconsistent results have been reported in observational studies concerning the association between green tea consumption and the lung cancer risk. In this commentary, several methodological issues underlying the measurement of tea exposure are highlighted. The recommendations should be useful for designing and planning prospective cohort studies to ascertain the protective effect of green tea against lung cancer.
M. H. Fauzi,S. Watanabe,N. Kumada,Y. Hirayama 한국물리학회 2012 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.60 No.10
We developed a sensitive spectroscopic tool to probe resistively as low as a few percent of an ensemble of nuclear spin polarizations in a GaAs quantum well. We take advantage of the spinphasetransition (SPT) peak of the filling fraction ν = 2/3 quantum Hall effect at which the electronic systems are energetically degenerate. The non-zero nuclear spin polarization incorporated in the system would be perceived as an effective magnetic field BN that modifies the Zeeman energy exclusively. It would result in a change in the overall shape of the peak including the peak’s position, width, and amplitude. The alteration of the shape of the overall peak provide essential information on the microscopic characteristics of nuclear spin polarization and its relation to the domain formations which was not well investigated in the previous reports.
Light-Ion Production from a Thin Silicon Target Bombarded by 175 MeV Quasi Monoenergetic Neutrons
S. Hirayama,Y. Watanabe,Y. Naitou,P. Andersson,R. Bevilacqua,C. Gustavsson,M. Osterlund,S. Pomp,V. Simutkin,H. Sjostrand,A. Hjalmarsson,A. Prokofiev,M. Tesinsky,U. Tippawan 한국물리학회 2011 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.59 No.23
Double-differential production yields of light ions (p, d, t, ^3He, and α from a thin silicon target induced by 175 MeV quasi mono-energetic neutrons were measured using the MEDLEY setup at the The Svedberg Laboratory (TSL) in Uppsala in order to benchmark evaluated nuclear data and nuclear reaction models. The MEDLEY is a conventional spectrometer system which consists of eight counter telescopes. Each telescope is composed of two silicon surface barrier detectors as the ΔE detectors and a CsI(Tl) scintillator as the E detector for particle identification. The telescopes are placed at angles from 20˚ to 160˚ in steps of 20˚. The measured double-differential yields of light ions are compared with PHITS calculations using the following nuclear reaction options: the high-energy nuclear data library (JENDL/HE-2007), the quantum molecular dynamics (QMD) model, and the intra-nuclear cascade (INC) model.