http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Bond Distortion and Electron States in Charged $C_{60}{^2-}$
Fu, Rong-Tang,Fu, Rou-Li,Lee, Kee-Hag,Sun, Xin,Ye, Hong-Juan Korean Chemical Society 1993 Bulletin of the Korean Chemical Society Vol.14 No.6
By considering both electron-electron and electron-lattice interactions, the effect of charge transfer on the bond structure and electronic states of $C_{60}$ is studied without configuration limitation. The results show that the electron-electron interaction does not eliminate the layer structure of the bond distortion and the self-trapping of transferred electrons. For charged ${C_{60}}^{2-}$, there exist two localized electronic states, which possess laminar wave functions, and four nonequivalent groups of carbon atoms, which induce a fine-structure in the NMR spectrum line.
Zhijian Fu,Li-Jun Jia,JIHONG XIA,Hai-Bo Ruan,Ke Tang,Yong Pu,Zhao-Yi Zeng,Dian-Yong Tang,Bo Kong,Qi-Feng Chen 성균관대학교(자연과학캠퍼스) 성균나노과학기술원 2016 NANO Vol.11 No.6
The equilibrium structure and electronic properties of four ultrathin free-standing pentagonal and hexagonal noble metal nanowires, that is, copper nanowires (CuNWs), silver nanowires (AgNWs), gold nanowires (AuNWs) and platinum nanowires (PtNWs), have been studied comprehensively by adopting a first-principles simulation based on the density-functional theory. The staggered topologies are more stable than the eclipsed ones by analyzing the bonding energy. The staggered ones with a linear atom chain in the center of the pentagonal or hexagons topologies are the preferred structures for CuNWs and AgNWs, but the staggered ones without a linear atom chain in the center of the pentagon or hexagon are the preferred structures for AuNWs and PtNWs due to the increasing core–core repulsions. The calculated electronic band structures and density of states present that all the noble metal nanowires are metallic. The projected densities of states (PDOS) of dominant d-states and the charge density show that the narrower d-state moved to the Fermi energy and metallic bonding character for all the noble metal nanowires.
Qiantang Fu,Chaoqiong Li,Mingyong Tang,Yan-Bin Tao,Bang-Zhen Pan,Lu Zhang,Longjian Niu,Huiying He,Xiulan Wang,Zeng-Fu Xu 한국식물생명공학회 2015 Plant biotechnology reports Vol.9 No.6
Jatropha curcas is considered a potential biodiesel feedstock crop. Currently, the value of J. curcas is limited because its seed yield is generally low. Transgenic modification is a promising approach to improve the seed yield of J. curcas. Although Agrobacterium-mediated genetic transformation of J. curcas has been pursued for several years, the transformation efficiency remains unsatisfying. Therefore, a highly efficient and simple Agrobacterium-mediated genetic transformation method for J. curcas should be developed. We examined and optimized several key factors that affect genetic transformation of J. curcas in this study. The results showed that the EHA105 strain was superior to the other three Agrobacterium tumefaciens strains for infecting J. curcas cotyledons, and the supplementation of 100 mM acetosyringone slightly increased the transient transformation frequency. Use of the appropriate inoculation method, optimal kanamycin concentration and appropriate duration of delayed selection also improved the efficiency of stable genetic transformation of J. curcas. The percentage of b-glucuronidase positive J. curcas shoots reached as high as 56.0 %, and 1.70 transformants per explant were obtained with this protocol. Furthermore, we optimized the root-inducing medium to achieve a rooting rate of 84.9 %. Stable integration of the T-DNA into the genomes of putative transgenic lines was confirmed by PCR and Southern blot analysis. Using this improved protocol, a large number of transgenic J. curcas plantlets can be routinely obtained within approximately 4 months. The detailed information provided here for each step of J. curcas transformation should enable successful implementation of this transgenic technology in other laboratories.
Wang, Fu-Ru,Fang, Qiao-Qiao,Tang, Wei-Ming,Xu, Xiao-San,Mahapatra, Tanmay,Mahapatra, Sanchita,Liu, Yu-Fei,Yu, Ning-Le,Sun, Quan-Fu Asian Pacific Journal of Cancer Prevention 2015 Asian Pacific journal of cancer prevention Vol.16 No.11
Medical diagnostic X-ray workers are one occupational group that expose to the long-term low-dose external radiation over their working lifetime, and they may under risk of different cancers. This study aims to determine the relationship between the occupational X-ray radiation exposure and cancer risk among these workers in Jiangsu, China. We conducted Nested case-control study to investigate the occupational X-ray radiation exposure and cancer risk. Data were collected through self-administered questionnaire, which includes but not limits to demographic data, personal behaviors and family history of cancer. Retrospective dose reconstruction was conducted to estimate the cumulative doses of the x-ray workers. Inferential statistics, t-test and 2 tests were used to compare the differences between each group. We used the logistic regression model to calculate the odds ratio (OR) and 95% confidence interval (CI) of cancer by adjusting the age, gender. All 34 breast cancer cases and 45 esophageal cancer cases that detected in a cohort conducted among health workers between 1950~2011 were included in this presented study, and 158 cancer-free controls were selected by frequency-matched (1:2). Our study found that the occupational radiation exposure was associated with a significantly increased cancer risk compared with the control, especially in breast cancer and esophageal cancer (adjusted OR=2.90, 95% CI: 1.19-7.04 for breast cancer; OR=4.19, 95% CI: 1.87-9.38 for esophageal cancer, and OR=3.43, 95% CI: 1.92-6.12 for total cancer, respectively). The occupational X-ray radiation exposure was associated with increasing cancer risk, which indicates that proper intervention and prevention strategies may be needed in order to bring down the occupational cancer risk.
Tang, Jian-Hua,Yan, Fu-Hua,Zhou, Mei-Ling,Xu, Peng-Ju,Zhou, Jian,Fan, Jia Asian Pacific Journal of Cancer Prevention 2013 Asian Pacific journal of cancer prevention Vol.14 No.5
Purpose: Hepatic resection is arguably the preferred treatment for huge hepatocellular carcinoma (H-HCC). Estimating the remnant liver volume is therefore essential. This study aimed to evaluate the feasibility of using computer-assisted volumetric analysis for this purpose. Methods: The study involved 40 patients with H-HCC. Laboratory examinations were conducted, and a contrast CT-scan revealed that 30 cases out of the participating 40 had single-lesion tumors. The remaining 10 had less than three satellite tumors. With the consensus of the team, two physicians conducted computer-assisted 3D segmentation of the liver, tumor, and vessels in each case. Volume was automatically computed from each segmented/labeled anatomical field. To estimate the resection volume, virtual lobectomy was applied to the main tumor. A margin greater than 1 cm was applied to the satellite tumors. Resectability was predicted by computing a ratio of functional liver resection (R) as (Vresected-Vtumor)/(Vtotal-Vtumor) x 100%, applying a threshold of 50% and 60% for cirrhotic and non-cirrhotic cases, respectively. This estimation was then compared with surgical findings. Results: Out of the 22 patients who had undergone hepatectomies, only one had an R that exceeded the threshold. Among the remaining 18 patients with non-resectable H-HCC, 12 had Rs that exceeded the specified ratio and the remaining 6 had Rs that were < 50%. Four of the patients who had Rs less than 50% underwent incomplete surgery due to operative findings of more extensive satellite tumors, vascular invasion, or metastasis. The other two cases did not undergo surgery because of the high risk involved in removing the tumor. Overall, the ratio of functional liver resection for estimating resectability correlated well with the other surgical findings. Conclusion: Efficient pre-operative resectability assessment of H-HCC using computer-assisted volumetric analysis is feasible.