http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Analytical and Design Method for the Global Stability of Modular Steel Buildings
Zhi-Hua Chen,Xu Zhong,Yang Liu,Jiadi Liu 한국강구조학회 2021 International Journal of Steel Structures Vol.21 No.5
Modular steel buildings (MSBs) are an innovative form of prefabricated buildings with many advantages related to the factory-manufactured construction process. However, technical issues in the global stability design remain ambiguous and induce either unsuitable or uneconomical results without understanding the eff ect of intermodule connections appropriately. In this study, one practical theoretical equation to determine the buckling length factor for the sway-permitted MSB was derived from a sub-assembly considering pinned or rigid inter-module connections. A large number of fi nite element models were then used to numerically validate the eff ectiveness of the theoretical equation and explore the main infl uencing factors including both intermodule connections and height-to-width ratios. Results indicated that the intermodule connections should be carefully considered when the fl oor beams are obviously larger than ceiling beams, and theoretical results can be accurate enough when the height-to-width ratios remain within 3.0. Moreover, the second-order analysis method for MSB was also performed by using nonlinear buckling analyses and then compared with the buckling length method to verify the previous fi ndings. Finally, the criterion in selecting the proper stability design procedure for MSB was discussed in depth.
An Efficient Multi-PCA Based On-line Monitoring Scheme for Multi-Stages Imperial Smelting Process
Zhi-kun Hu,Zhi-wen Chen,Wei-Hua Gui,Chun-hua Yang,Lin-zi Yin,Xiao-qi Peng 제어·로봇·시스템학회 2013 International Journal of Control, Automation, and Vol.11 No.2
Imperial Smelting Process (ISP) is one of the main methods for Zinc and Lead smelting. In this paper, we firstly focus on its unique characteristics that ISP consists of many feeding cycles repeated in a similar way, and the normal process changes and multiple operating conditions would be frequently found in the process which would always lead to false alarms. To this end, we classify each feeding cycles of ISP into initial stage, transition stage, and steady stage, and use standard PCA, first order perturbation (FOP) based recursive dynamic PCA and multi-mode approach to deal with them respectively. The monitoring results using real data show that the proposed scheme can be able to eliminate false alarms and detect faults efficiently.
A new experimental technique on the tubular joints of spatial grid structures
Zhi-Hua Chen,Guo-Jun Sun,Zhi-Shan Luo 국제구조공학회 2011 Structural Engineering and Mechanics, An Int'l Jou Vol.40 No.6
A new experimental technique was developed on the plate-inserted welded tubular joints of spatial grid structures. In the experimental technique, a microcomputer controlling instrument of moire intervention (MCIMI) was adopted. A test was designed on the plate-inserted welded tubular joints of spatial grid structures to show the effectiveness of the MCIMI technique. Both traditional electrical measuring technique and MCIMI technique were employed in the test. The test results showed that the MCIMI technique was feasible in the case of the complicated tests on steel structures. The MCIMI technique not only implemented the limitation of traditional electrical measuring technique, but also improved the accuracy of the test. According to the test results, we further examined the plate-inserted welded tubular joints in the cable-stayed spatial grids of the Binhai International Convention & Exhibition in Tianjin, China. The analysis showed the joints are safely designed with adequate conservatism. The research provided a new application of MCIMI in the field of large-scale structure engineering.
A Simplified Numerical Model for Post-tensioned Steel Connections with Bolted Angles
Zhi-Hua Chen,Hongxing Li,Zhongwei Zhao,Haiqing Liu 한국강구조학회 2017 International Journal of Steel Structures Vol.17 No.4
Post-tensioned (PT) self-centering beam–column connections has been developed for its good seismic performance. Many researchers have investigated its mechanical behavior by numerical or experimental method. Prior researches have indicated that the analysis by elaborate FE models is very time consuming. To overcome this disadvantage, a simplified numerical model was established in this paper. The accuracy of results derived by this model was validated against prior investigations on interior PT connections with top-and-seat angles. Influence of initial PT force on mechanical behavior of PT connection was investigated. The Geometric and material nonlinearities, and strands can be considered in the modeling. A planar steel frame structure was established and hysteretic analysis was conducted. Results indicated that the computational cost can be greatly reduced by this model.
A new experimental technique on the tubular joints of spatial grid structures
Chen, Zhi-Hua,Sun, Guo-Jun,Luo, Zhi-Shan Techno-Press 2011 Structural Engineering and Mechanics, An Int'l Jou Vol.40 No.6
A new experimental technique was developed on the plate-inserted welded tubular joints of spatial grid structures. In the experimental technique, a microcomputer controlling instrument of moire intervention (MCIMI) was adopted. A test was designed on the plate-inserted welded tubular joints of spatial grid structures to show the effectiveness of the MCIMI technique. Both traditional electrical measuring technique and MCIMI technique were employed in the test. The test results showed that the MCIMI technique was feasible in the case of the complicated tests on steel structures. The MCIMI technique not only implemented the limitation of traditional electrical measuring technique, but also improved the accuracy of the test. According to the test results, we further examined the plate-inserted welded tubular joints in the cable-stayed spatial grids of the Binhai International Convention & Exhibition in Tianjin, China. The analysis showed the joints are safely designed with adequate conservatism. The research provided a new application of MCIMI in the field of large-scale structure engineering.
Zhi-qiang Li,Dan Gui,Zhi-hua Sun,Jun-bo Zhang,Wen-zhi Zhang,Hui Zhang,Fei Guo,Chuangfu Chen 대한수의학회 2015 Journal of Veterinary Science Vol.16 No.4
Brucellosis is a zoonotic disease that causes animal and human diseases. Vaccination is a major measure for prevention of brucellosis, but it is currently not possible to distinguish vaccinated animals from those that have been naturally infected. Therefore, in this study, we constructed the Brucella (B.) abortus 2380 wbkA mutant (2308DwbkA) and evaluated its virulence. The survival of 2308DwbkA was attenuated in murine macrophage (RAW 264.7) and BALB/c mice, and it induced high protective immunity in mice. The wbkA mutant elicited an anti-Brucella-specific immunoglobulin G response and induced the secretion of gamma interferon. Antibodies to 2308DwbkA could be detected in sera from mice, implying the potential for use of this protein as a diagnostic antigen. The WbkA antigen would allow serological differentiation between infected and vaccinated animals. These results suggest that 2308DwbkA is a potential attenuated vaccine against 16M. This vaccine will be further evaluated in sheep.
TOSS: Telecom Operations Support Systems for Broadband Services
Chen, Yuan-Kai,Hsu, Chang-Ping,Hu, Chung-Hua,Lin, Rong-Syh,Lin, Yi-Bing,Lyu, Jian-Zhi,Wu, Wudy,Young, Hey-Chyi Korea Information Processing Society 2010 Journal of information processing systems Vol.6 No.1
Due to the convergence of voice, data, and video, today's telecom operators are facing the complexity of service and network management to offer differentiated value-added services that meet customer expectations. Without the operations support of well-developed Business Support System/Operations Support System (BSS/OSS), it is difficult to timely and effectively provide competitive services upon customer request. In this paper, a suite of NGOSS-based Telecom OSS (TOSS) is developed for the support of fulfillment and assurance operations of telecom services and IT services. Four OSS groups, TOSS-P (intelligent service provisioning), TOSS-N (integrated large-scale network management), TOSS-T (trouble handling and resolution), and TOSS-Q (end-to-end service quality management), are organized and integrated following the standard telecom operation processes (i.e., eTOM). We use IPTV and IP-VPN operation scenarios to show how these OSS groups co-work to support daily business operations with the benefits of cost reduction and revenue acceleration.
Efficacy of Pap Test in Combination with ThinPrep Cytological Test in Screening for Cervical Cancer
Chen, Hua,Shu, Hui-Min,Chang, Zhou-Lin,Wang, Zhi-Feng,Yao, Hai-Hong,Zhu, Hong-Mei,Lu, Tian-Mei,Ma, Qiang-Yan,Yang, Bin-Lie Asian Pacific Journal of Cancer Prevention 2012 Asian Pacific journal of cancer prevention Vol.13 No.4
Background: Our aim was to investigate the efficacy of the Pap test in combination with the ThinPrep cytological test (TCT) in screening for cervical cancer in China. Design: From March 2006 to October 2008, 988 women with the mean age $46.4{\pm}10.5$ years (range, 23-80 years) were recruited to receive cervical cancer screening. Pap test results ${\geq}$ grade III and TCT findings ${\geq}$ ASCUS/AGUS were considered abnormal. Subjects with a Pap test result ${\geq}$ grade IIb received TCT. Colposcopy and biopsies were performed in all participants, and final diagnosis was based on pathological findings. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and Youden index for predicting CIN I or above were determined. Results: The sensitivity, specificity, PPV, NPV and Youden index of the Pap test were 43.1%, 97.2%, 70.0%, 91.9%, and 40.3%, respectively. The same values for TCT in predicting CIN were 80.0%, 63.2%, 16.0%, 97.3%, and 43.2%, respectively. The two tests in combination gave values for predicting CIN of 64.8%, 87.6%, 43.6%, 94.4%, and 53.5%, respectively. Combined testing exhibited the highest Youden index (53.4%). Conclusion: The Pap test with a reduced threshold in combination with the TCT has high sensitivity and high specificity in screening for cervical cancer.