RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 단일 Database Field를 이용한 PHP 무한 File Upload 구현

        황기환,변기환,이지영,Hwang, Ki-Hwan,Byun, Ki-Hwan,Lee, Jie-Young 한국정보기술전략혁신학회 2009 情報學硏究 Vol.12 No.2

        Currently the Web, multiple files in the Client to upload to the server of the multi-upload method, files are stored in specific folders on the server, the file name field in DB(Database Field) stored in a way that the process has been widely utilized. Therefore, a minimum number of file upload as many file names in the Database and the Table should be created in the field, but also a variable number of files can be uploaded has no limits. In this paper we proposed the new method that files to be uploaded to the server, you can upload a limited number of files, nor due to upload files to reduce load on the database to improve the processing speed of a single field using a multi-method file uploads using PHP directly implemented

      • KCI등재

        STAM 토모그라픽 영상의 분해능 해석

        황기환,고대식,전계석,Hwang, Ki-Hwan,Ko, Dae-Sik,Jun, Kye-Suk 한국음향학회 1997 韓國音響學會誌 Vol.16 No.1

        본 논문에서는 음향-광 효과를 이용한 STAM 시스템으로부터 얻을 수 있는 토모그라픽 영상의 분해능을 해석하였다. 이를 위하여 BFP 토모그라픽 복원 알고리즘을 이용하여 초음파변환기 회전장치와 시료 회전장치에 대한 측방향과 축방향 분해능을 해석하였다. Matlab을 이용한 분석결과, 축방향 분해능은 두 회전장치 모두 약 1.5 파장정도로 좋은 분해능을 나타내었다. 측방향 분해능은 시료 회전장치인 경우 x와 yqkdgid에서 0.53 파장의 동일한 분해능을 보였으며 초음파변환기 회전장치인 경우에는 x와 yqkdgid에서 각각 0.56 및 0.70 파장의 분해능을 나타내었다. 결과적으로 STAM 시스템은 시료회전장치를 사용할 때 더 좋은 분해능을 얻을 수 있음을 보였다. In this paper, we analyzed the resolution of tomographic images which can be obtained with Scanning Tomographic Acoustic Microscope(STAM) utilizing the acousto-optic effect. To realize this, lateral and depth resolutions of both ultrasonic transducer and specimen rotating device are obtained by using BFP tomographic reconstruction algorithm. Simulation results show that both rotating devices have a good depth resolution of $1.5{\lambda}$. For the lateral resolution, the specimen rotating device produces $0.53{\lambda}$ in the x and y directions and the transducer rotating device produces $0.56{\lambda}$ and $0.70{\lambda}$ in the x and y directions respectively. These results imply that the specimen rotating device is more suitable for STAM system construction.

      • KCI등재

        STAM 시스템을 이용한 토모그라픽 영상 복원

        황기환,김현,김종찬,전계석,Hwang, Ki-Hwan,Kim, Hyun,Kim, Jong-Chan,Jun, Kye-Suk 한국음향학회 1998 韓國音響學會誌 Vol.17 No.8

        본 논문에서는 다층구조물에 대한 토모그라픽 영상을 복원하기 위해 기존의 SLAM 시스템에 쿼드러쳐 검출기와 시료회전장치를 부가하여 STAM 시스템을 구성하고 BFP 알 고리즘을 이용하여 영상복원 프로그램을 개발하였다. 본 실험에서는 시료로서 알루미늄을 사용하여 2개 층이 서로 다른 패턴을 갖는 불균질 층을 만들고 그 사이를 물로써 채워진 다 층구조물을 구성하였으며 또한 불균질 층 간격을 각각 8λ, 10λ 그리고 12λ가 되도록 제 작하였다. 이들 시료는 STAM 시스템에서 4중 프로젝션(0°, 90°, 180°, 270°)시켜 토모 그라픽 데이터를 획득하고 이를 영상처리하여 토모그라픽 영상을 복원하였다. 영상분석 결 과, 본 STAM 시스템은 4중 프로젝션시 12λ의 불균질 층 간격에서 높은 분해능의 토모그 라픽 영상을 얻을 수 있었고 각 층에 대한 위치를 결정할 수 있었다.

      • KCI등재후보

        Endovascular Treatment for Acute Ischemic Stroke Patients over 80 Years of Age

        황기환,Gyojun Hwang,권오기,Chang Hyeun Kim,Seung Pil Ban,한문구,배희준,Beom Joon Kim,Jae Seung Bang,오창완,Boram Lee,Eun-A Jeong 대한뇌혈관외과학회 2015 Journal of Cerebrovascular and Endovascular Neuros Vol.17 No.3

        Objective:We evaluated the effect of endovascular treatment (EVT) for acute ischemic stroke in patients over 80 years of age. Materials and Methods:The records of 156 acute stroke patients aged over 80 years who were considered as candidates for EVT were analyzed. Fifty-six patients (35.9%, EVT group) underwent EVT and 100 patients (64.1%, non-EVT group) did not. Outcomes, in terms of functional outcomes and rates of symptomatic hemorrhage, in-hospital morbidity and mortality, were compared between groups. Each comparison was adjusted for age, time from onset, initial National Institute of Health Stroke Scale, and pre-stroke modified Rankin Scale (mRS). Results:More patients in the EVT group achieved good outcomes (mRS score of 0-2) at 3 months (35.7% vs. 11.0%, adjusted odds ratio [OR] 4.779 [95% confidence interval 1.972-11.579], p = 0.001) and 12 months (35.7% vs. 14.0%, adjusted OR 3.705 [1.574-8.722], p = 0.003) after stroke. During admission, rates of hospital-acquired infection including pneumonia (12.5% vs. 29.0%, adjusted OR 0.262 [0.098-0.703], p = 0.008) and urinary tract infection (16.0% vs. 34.0%, adjusted OR 0.256 [0.099-0.657], p = 0.005) were significantly lower in the EVT group. More symptomatic hemorrhages (10.7% vs. 2.0%, adjusted OR 6.859 [1.139-41.317], p = 0.036) occurred in the EVT group, but no significant difference was observed in in-hospital mortality rate (12.5% vs. 8.0%, adjusted OR 1.380 [0.408-4.664], p = 0.604). Conclusion:EVT improved functional outcome and reduced the risk of hospital-acquired infections in acute stroke patients over 80 years of age without increasing the risk of in-hospital mortality, although symptomatic hemorrhage occurred more frequently after EVT.

      • KCI등재후보

        CT Fluoroscopy-guided Aspiration of Intracerebral Hematomas: Technique and Outcomes

        황기환,Gyojun Hwang,권오기,Jae Seung Bang,오창완 대한뇌혈관외과학회 2015 Journal of Cerebrovascular and Endovascular Neuros Vol.17 No.1

        Objective:The authors evaluated the feasibility and targeting accuracy of CT fluoroscopy (CTF)-guided catheter placement and aspiration of intracerebral hematoma (ICH)s. Materials and Methods:Nine patients (mean age, 63.3 ± 15.3 years) were treated by CTF-guided hematoma aspiration under local anesthesia. The targeting errors in the lesion center, volume of the aspirated hematoma, accuracy of the final catheter position, procedure time, and clinical outcomes were evaluated. Results:All catheters were successfully placed in the center of the hematoma. The mean volume of the aspirated hematoma was 20.6 ± 8.8 mL (pre-treatment, 44.7 ± 20.1 mL; post-treatment, 24.1 ± 13.8 mL). The average procedure time was 25.1 minutes (range, 18-32 minutes). In one case with a scanty residual hematoma, the catheter was removed at the end of the procedure. In the remaining eight cases, the catheter was left in the residual hematoma for drainage and all catheter tips were accurately located in the final position. There were no procedure-related complications, including rebleeding and infection. Conclusion:CTF-guided ICH aspiration is a feasible, quick, and accurate procedure which could substitute for stereotactic methods. The accurate catheter position provided by real-time observation enables an effective aspiration and drainage of hematomas.

      • KCI등재

        SLAM 영상을 이용한 크랙 깊이 측정

        황기환,전계석,Hwang, Ki-Hwan,Jun, Kye-Suk 한국음향학회 1997 韓國音響學會誌 Vol.16 No.3

        본 논문에서는 SLAM(Scanning Laser Acoustic Microscope) 시스템을 이용하여 고체 내부에 발생한 크랙의 깊이를 측정하는 방법을 연구하였다. SLAM 시스템은 초음파의 투과계수에 따른 그림자 영상을 재생시키므로 크랙 깊이에 대한 정확한 측정방법이 요구된다. 이를 위하여 시료에 초음파를 사각으로 입사시켜 얻은 SLAM 영상의 그림자영역과 시료내의 초음파 모드 변환에 대한 기하학적 구조를 이용하여 크랙의 깊이를 측정할 수 있는 방법을 제안하고 실험을 통하여 확인하였다. 실험을 위하여 알루미늄에 서로 다른 깊이로 수직형 라인-크랙의 결함을 갖는 시료를 가공하였고 시료에 초음파를 사각 입사시키기 위하여 20$^{\circ}$ 각도로 웨지를 제작하였다. 실험 결과, 크랙의 깊이가 증가할수록 SLAM 영상의 그림자 영역이 비례적으로 증가함을 보였고, 결함의 깊이에 대한 측정치와 실제치를 비교한 결과 약 6% 이하의 측정오차를 보였다. In this paper, we studied the configuration and depth measurement method of the crack in the interior of solid with scanning laser acoustic microscope. Precision measurement method of crack depth is required in SLAM because that system reconstructs the shadow image to the transmission coefficient. We proposed this method that used geometrical structure to the shadow area of SLAM images obtained from oblique incidence and the mode conversion of ultrasound in specimen and then experimented it. For this experiment, we fabricated various specimens which had the vertical line-crack with different depth and made the wedge as 20$^{\circ}$ for oblique incidence. Experimental results showed that the shadow area of SLAM images were proportional to the depth of crack. Measured depth error to the crack was less than 6% compared with practical crack depth.

      • KCI등재후보

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼