http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Gerdien 이온측정기를 이용한 에어로졸의 하전 특성 분석에 관한 연구
조윤행,심준목,신일경,육세진,박현설,Joe, Yun-Haeng,Shim, Joonmok,Shin, Il-Kyoung,Yook, Se-Jin,Park, Hyun-Seol 한국입자에어로졸학회 2018 Particle and Aerosol Research Vol.14 No.1
Since the motion of the charged particle strongly depends on its charge characteristics, information on charge distributions of target particles is one of the important variables in aerosol research. In this study, charged distribution of atomized NaCl particles were measured using a Gerdien type ion counter. Two kinds of particle charging conditions were used in this study. First, atomized NaCl particles were passed through an aerosol neutralizer to have a Boltzmann charge distribution, and then its charge distribution was measured. In this case, the portion of uncharged particles was compared with the portion obtained from the Boltzmann charge distribution for verifying the suggested experimental method. Second, same experiment was conducted without the aerosol neutralizer to measure the charge distribution of atomized and un-neutralized NaCl particles. In the conclusion, the portion of uncharged, negatively charged and positively charged particles were 19%, 62% and 20%, respectively, for neutralized particles. The atomized particles, which was generated without the aerosol neutralizer, also had almost a zero charge state, but the standard deviation in charge distribution was larger than that of neutralized particles. The test method proposed in this study is expected to be used in various aerosol research fields because it can obtain simple information on the particle charge characteristics more easily and quickly than the existing test methods.
조윤행,신동호,박현설,허지은,심준목,Joe, Yun-Haeng,Shin, Dongho,Park, Hyun-Seol,Heo, Jieun,Shim, Joonmok 한국입자에어로졸학회 2021 Particle and Aerosol Research Vol.17 No.2
In this study, the clean air delivery rate (CADR) of ceiling air circulator (CAA) was determined under indoor environmental simulation conditions. An air filter was used to provide air cleaning ability to the CAA. The CADR of filter adapted CAA was evaluated and compared with the value of commercial air purifier. The installation of mesh-shaped filter on the CAA showed particle reduction effect on the particles over 0.4 ㎛ in diameter, but the CADR was up to 0.25 m<sup>3</sup>/min. When the filter having 99.9% in collection efficiency was installed on the CAA, its CADR was 1.52 m<sup>3</sup>/min, while the CADR of commercial air purifier was 3.19 m<sup>3</sup>/min.
에어로졸 공정을 이용한 전열교환기의 은나노 입자 코팅 및 항균 능력과 열교환 성능 평가
조윤행(Yun-Haeng Joe),박철우(Chul-Woo Park),박재홍(Jae-Hong Park),황정호(Jungho Hwang) 한국실내환경학회 2011 한국실내환경학회지 Vol.8 No.1
In this study, an enthalpy exchanger was coated by silver nano particles via spark discharge method and its antimicrobial and heat exchange efficiencies were evaluated. A method utilizing thermophoretic force was used to improve coating efficiency. Four spark discharge systems were parallel connected and generated silver nano aerosol particles (number concentration of 1.65×108 particles/cc, mode diameter of 31 nm). The coating efficiency was evaluated according to various face velocities (V=0.25~1 m/s) and temperature gradients ((Thot-Tcold)/Thot=0~0.09). The maximum coating efficiency was 90.8 % when the face velocity was 0.25 m/s and the temperature gradient was 0.09 (Thot=30℃, Tcold=2℃). Silver nano particles were coated onto the enthalpy exchange element and two different coating amounts of silver nano particles (0.11㎍/㎠, 0.22㎍/㎠) were tested. For evaluation of antimicrobial efficiency, the suspension test method with E. coli was used. After the suspension test method, CFU(colony forming unit)s of each test sample were counted and colony ratio was calculated. The colony ratio was decreased more quickly when the amount of coated silver particles was increased. When the contact time between each sample and suspension was over 3 hours, antimicrobial efficiencies of coated samples were more over 99.9 % for both amount of silver nano particle(0.11㎍/㎠, 0.22㎍/㎠). The coating of silver nano particles did not affect the heat exchange efficiency.
대용량 입자 발생 장치 개발 및 이를 이용한 항바이러스 공조용 공기필터 제조
박대훈,조윤행,황정호,Park, Dae Hoon,Joe, Yun Haeng,Hwang, Jungho 한국입자에어로졸학회 2016 Particle and Aerosol Research Vol.12 No.4
Since airborne viruses have been known to aggravate indoor air quality, studies on development of anti-viral air filter increase recently. In this study, a mass aerosol particle generator for coating a commercial air filter (over $300{\times}300mm^2$) was built, and evaluated by comparing a commercial particle generator. Then, via this device, a commercial air filter was coated with anti-viral material ($SiO_2-Ag$ nanoparticles in this study), so fabrication of commercial anti-viral air filter was performed and the pressure drop, filtration efficiency, and anti-viral ability of the filter were evaluated against aerosolized bacteriophage MS2 in a continuous air flow condition. The result showed that the particle generation of the new generator was more than about 8.5 times over which of the commercial one. Consequently, $SiO_2-Ag$ particle coating on a filter does not have significant effects on the filtration efficiency and pressure drop with different areas, and the average anti-viral efficiency of the $SiO_2-Ag$ filter was about 92% when the coating areal density was $1.0{\times}10^{12}particles/m^2$.
밀폐공간에서 비말 가림막 높이에 따른 감염성 비말 공기전파 차단능력 평가
허지은,조희주,박현설,신동호,심준목,조윤행,Heo, Jieun,Cho, Hee-joo,Park, Hyun-Seol,Shin, Dongho,Shim, Joonmok,Joe, Yun-Haeng 한국입자에어로졸학회 2021 Particle and Aerosol Research Vol.17 No.2
Although the installation of droplet protection screen (DPS) is known to prevent droplet transmission, there is still a lack of knowledge in effectiveness of DPS installation to block the airborne transmission. In this study, the prevention ability of DPS against airborne transmission was evaluated according to the DPS height. When the DPS was not installed, the maximum concentration of PM1.0 at the location opposite to infected person was 35% of that at the infected person location. When the DPS was installed, the DPS effectively prevented the airborne transmission, consequently approximately 7% of generated particles were measured at the opposite location from particle generation position (infected person location). The prevention ability of DPS increased with DPS height, the maximum prevention efficiency of 95.1% was obtained when the DPS height was 900mm. Moreover, the speed of airborne transmission was delayed by installation of DPS, and the delay time increased with DPS height.