http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
물놀이형 수경시설의 수질과 항생제 내성 대장균 분포에 관한 연구
윤상훈,김선경,김난희,위환,이세행,조광운,김동수,조영관,Yoon, Sang-Hoon,Kim, Seon-Gyeong,Kim, Nan-Hee,Wi, Whan,Lee, Se-Hang,Jo, Gwang-Woon,Kim, Dong-Su,Cho, Young-Gwan 한국환경보건학회 2014 한국환경보건학회지 Vol.40 No.3
Objective: This study was performed in order to investigate the distribution of antibiotic resistant E. coli and water quality in waterscape facilities. Methods: Nine waterscape facilities were selected and classified into three types: ground, wall and general fountain. The items analyzed in this study were pH, turbidity, $KMnO_4$ consumption, total colony, total coliforms, fecal coliforms and E. coli. Additionally, an antibiotic resistance test on E. coli was performed. Results: There were no sampling sites that exceeded the permitted limits of water quality, but the concentration of pollutants was high at the beginning operation in June. Moreover, concentration of turbidity, $KMnO_4$ consumption and total colony were higher in ground fountains than in wall and general fountains. Five species of antibiotic resistant E. coli were detected from three sampling sites. Conclusions: The waterscape facilities were significantly contaminated with water microorganisms, especially total colony, total coliforms and fecal coliforms. Disinfection and filtration systems to remove pollutants should be installed for safe waterscape facilities.
소규모 세탁소의 휘발성유기화합물 발생 특성과 종사자의 건강에 미치는 영향
박옥현 ( Ok-hyun Park ),이경석 ( Kyoung-seok Lee ),민경우 ( Kyoung-woo Min ),조광운 ( Gwang-woon Cho ),윤관주 ( Kwan-ju Yoon ),정원삼 ( Won-sam Jeong ),조영관 ( Young-gwan Cho ),김은선 ( Eun-sun Kim ),양진석 ( Jin-seok Yang ) 한국산업보건학회 (구 한국산업위생학회) 2016 한국산업보건학회지 Vol.26 No.2
Objectives: The objective of this study was to evaluate the generating characteristics of VOCs and the exposure effect to chemicals among laundry workers and to identify the current status of occupational safety and health through health check-ups. Methods: During the six-month period from April to September 2015, this study quantitatively measured seven VOCs in ten laundries and carried out health examinations on 35 workers. Results: Comparing the monitoring results for the ten laundries, they were classified into three groups by ventilation system, dry-cleaning and size of shop. The average concentration of toluene, chlorobenzene, xylene, ethylbenzene, benzene, styrene and TCE were 23.9, 15.6, 5.5, 2.8, 0.9, 0.3 and 1.3 ㎍/m3, respectively. During dry-cleaning, VOC concentrations were 1.3-8.9 times higher than usual. On the other hand, at night the concentrations of toluene, chlorobenzene, xylene, ethylbenzene, benzene, styrene and TCE were 64.3, 41.5, 12.2, 6.3, 1.1, 1.2 and 6.6 ㎍/m3, respectively. The health checkup results for the 35 workers showed that 13 workers were diagnosed as normal, while 22 workers were diagnosed as requiring continuous monitoring or re-checkup of liver and hematogenous functions. Conclusions: Although the results of exposure evaluation to VOCs did not exceed reference value and items had a low correlation with health checkup items, it is necessary to improve indoor air quality due to VOC volatilization from clothes
네일샵 종사자의 휘발성유기화합물 노출실태와 건강에 미치는 영향
김난희 ( Nan-hee Kim ),민경우 ( Kyoung-woo Min ),조광운 ( Gwang-woon Cho ),서동주 ( Dong-ju Seo ),임경훈 ( Kyeong-hun Im ),정원삼 ( Won-sam Jeung ),조영관 ( Young-gwan Cho ),양진석 ( Jin-seok Yang ) 한국산업보건학회 (구 한국산업위생학회) 2017 한국산업보건학회지 Vol.27 No.1
Objectives: The objective of this study is to evaluate the exposure of VOCs and effects of the chemicals on the nail technicians whose works in a nail shop. Methods: For four month from May to August in 2016, we measured twenty-two kinds of VOCs in ten nail shops and carried out health examinations on thirty-four workers in there. Results: The TVOC concentration in indoor air of nail shops is 0.487 ㎎/㎥ at a minimum and 33.236 ㎎/㎥ at a maximum where it consists of 70.5% of Ketones, 25.4% of Alcohols, 2.6% of Esters, 0.8% of Aldehydes and 0.7% of Aromatics. The VOCs concentration during nail art works shows an increase in average ratio 1.8 compared to the concentration of indoor air quality and also the concentration of Isopropanol rose with 3.2 of the highest ratio. The results of Spearman correlation between TVOC concentration in indoor air and environmental factor was like that has significance level of correlation(ρ<0.05, r=0.682) in case of number of customers per day, but the other factors were not meaningful in correlation. Correlation between VOCs and medical check-up items was like that has positive significance level(ρ<0.01, r=0.638) between isopropanol and GPT, but the others have not meaningful. The exposure level of VOCs was not exceed the criteria exposure level 1 of working environment measuring method which announced by labor ministry in all ten nail shop indoor air quality. Conclusions: In this study although it was not significant correlation between harmful substances and medical check-up items in the nail shop indoor air quality, it is necessary to do more ventilation and to install exhaust facilities because of existing high VOCs concentration in the nail shop indoor air.