http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
운전조건에 따른 히트파이프를 이용한 열교환기의 특성에 관한 연구
이영수,장영석,Lee, Y.S.,Jang, Y.S. 대한설비공학회 1990 설비공학 논문집 Vol.2 No.3
The purpose of this research is to study the characteristics of heat exchanger using heat pipe under various working conditions by a finite element analysis and experiment. The results are as follows. 1) In this study, h = $Max^B$ is used for the convective heat transfer coefficient and A = 2.761 and B = 0.701 $Mmax^{(-0.0626)}$ were obtained as the results of experiment. 2) For several different working conditions, (Q/Qb) is predicted by varying the values of L/Lt and Re/Rc. The maximum value of (Q/Qb) is achieved when Re/Rc = 1 and Le/Lc = 0.5. 3) The comparison between calculated value and experimental data showed agreement within 5% error. Therefore the method may be used to predict the performance of heat exchanger using heat pipe for similar geometric conditions. 4) For Re/Re/Rc of 0.2-0.3, the minimum thermal resistance exists when Le/Lt is 0.4-0.65.
우리나라 산업보건관리(産業保健管理) 평가기준(評價基準)과 실태(實態)에 관(關)한 연구(硏究)
이영수,문영한,김영기,정호근,Lee, Y.S.,Moon, Y.H.,Kim, Y.K.,Chung, H.K. 대한예방의학회 1978 Journal of Preventive Medicine and Public Health Vol.11 No.1
The study was carried out for 101 establishments in Kyong-In areas to evaluate the industrial health management status utilizing the scoring method by Webb's model during the period from 1 September to October 30, 1977. To compare the results, reevaluation was made with the 45 questions' model prepared by 6 Korean professionals who were specialized in industrial health fields. The results were as follows: 1. The mean rate of affirmative answers for 101 establishments was 51.6%. The mean weighted score rate of affirmative answers was 52.3%. 2. The mean rate of affirmative answers on components of the philosophy and facility resource for 101 establishments was higher than that of average rate. The mean rate of affirmative answers on components of the health evaluation and health management among the health service program was lower than that of average rate. 3. The mean rate of affirmative answers on components was highter among the establishments with more than 500 employees. The mean rate of affirmative answers of chemical establishment was lower than that of others. 4. The mean rate of affirmative answers on 45 questions' model for 101 establishments were 67.1%. The mean weighted score rate of affirmative answers was 70.0%. 5. In case of 45 questions' model, the mean rate of affirmative answers on components of philosophy and treatment was higher than that of average rate and the mean rate of affirmative answers on components of the facility resource and the health evaluation was lower than that of average rate. 6. The mean rate of affirmative answers of the 45 Questions' model was higher than that of Webb's model in size and class of 101 establishments. Author concluded that Webb's model must be suitable for evaluating higher conditions of occupational health management than is presently used in Korean establishments. According to the results, however, there were no significant differences between Webb's model and the 45 questions' model. So it could be used to evaluate Occupational Health Program. For this objective, in Korean occupational situations, further study also must be made comprehensively thereafter.
열(熱)펌프시스템에서 각종(各種) 설계인자(設計因子)들에 따른 응축기(凝縮器)의 최적설계(最的設計)에 관한 연구(硏究)
이영수,김남국,Lee, Y.S.,Kim, N.K. 대한설비공학회 1988 설비저널 Vol.17 No.4
This study optimized the condenser dimension of heat pump system with the heat sources which are solar irradiation and ambient air. At first, the author selected the principal design factors influencing the performance of heat pump system. And the author considered the variation of condenser dimension according to the variation of the selected design factors, that is, ambient air temperature, condenser temperature, degree of superheating, degree of sub-cooling and irradiation. As a result this study, among refrigerants R12, R22 and R500, refrigerant R22 has more heating output than R12 and R500, and the coefficient of performance on this heat pump system is not greatly influenced by the degree of superheating and degree of sub cooling. The ambient air temperature is below $5^{\circ}C$ at balance point and the optimal tube length of condenser dimension is about 3.8 m. Also the author gained the optimal design diagram for the optimization of condenser dimension according to various design factors.
태양열 난방시스템 해석을 위한 전산시뮬레이션 모델의 개발
이영수,서정일,Lee Y. S.,Seoh J. I. 대한설비공학회 1987 설비저널 Vol.16 No.1
This research, through the analysis of existing programs, presents a simplified logical program which can show the thermal performance of a system, based only on hourly weather data and the system design data. This program is applicable for analyzing a system of direct heating or recirculation heating which may enhance the performance of an existing solar house. Using these system in the existing systems a little raise in performance. The model analysis of a $100\;m^2$ solar house in the seoul region shows that the following figures are the most efficient and suitable; 1. Installation an81e of collector: $45^{\circ}$ 2. Collector size: $34.56\;m^2$ 3. Capacity of main storage tank: $25\;m^3$