The main purpose of this dissertation is to discuss and analyze the effect of immunoglobulin on exercise intensity in the elderly women over 70. For the purpose, this researcher 6 elderly women 70 or over who had no experience of exercise program participation, had no problem in using motor functions for daily life and agreed to participate in the study. Those elderly women were asked to participate in dance sport Dance sport programs were performed one time per week for three weeks with RPE 9~13 intensity corresponding to 45-70%HRmax(low intensity : 45~53%HRmax, middle intensity : 55~60%HRmax, high intensity : 65~70%HRmax). The following conclusion can be obtained by analyzing and comparing the change of immunoglobulin on exercise intensity in the elderly women over 70 years. IgG is increase in 55~60%HRmax and 65~70%HRmax. If we judge the result of analyzing immunoglobulin on exercise intensity, immunoglobulin of 55~60%HRmax and 65~70%HRmax are better than 45~50%HRmax, but their concrete and detailed mechanism is not yet explained fully. Elderly people`s disease is mainly due to the degeneration of their immunoglobulin. For this reason, exercise intensity suitable for those people should be carefully considered in exercise intensity and exercise program. Therefore, there needs more continuous and profound researches on the immunoglobulin.
학교 건물에서 환기시스템에 의한 교실내 공기질 측정 및 성능평가
신희수(Hee-Soo Shin),이재근(Jae-Keun Lee),이재권(Jai-Kwon Lee),이감규(Kam-Gyu Lee) 대한기계학회 2005 대한기계학회 춘추학술대회 Vol.2005 No.5
This paper describes to evaluate the performance of ventilation for investigating the removal of indoor pollutants as a function of ventilation rate and the number of occupants in the school classroom. Variations of the gas concentration as a function of time are measured at center point of classroom and air exchange rates with the CO₂ gas monitor. For the ventilator of 800 CMH in the classroom with the existence of 35 students, the average CO₂ concentration is 913 ppm. A ventilator of 800 CMH is sufficient to meet acceptable indoor air quality in the classroom of 35 students, a maximum number of students based on the Korea school standard below 1,000 ppm of CO₂.
전기응집 및 전기탈수을 이용한 슬러지 탈수 성능평가 분석
신희수(Heesoo Shin),여창신(Changsin Yeo),변상현(Sanghyun Byun),이재근(Jaekeun Lee) 대한기계학회 2003 대한기계학회 춘추학술대회 Vol.2003 No.4
This study is to develop the pretreatment for the excess and digested sludge by electro-coagulation and dewatering. Electrocoagulation is applied to excess and digested sludge before transferring to the piston type press for dewatering. Piston type press as a laboratory scale plant was used to estimate the dewaterability.<br/> MMD of excess sludge was increased from initial diameter of particles(34.16㎛) to the 87%(64.01㎛) after electrocoagulation. AI electrode is more effective than Fe electrode for the dewaterability of excess sludge. Electrodewatering after electrocoagulation as pretreatment makes the water content of sludge cake 50~60 wt%.
신희수(Hee-Soo Shin),여창신(Chang-Shin Yeo),변상현(Shang-Hyun Byun),안영철(Young-Chull Ahn),이재근(Jae-Keun Lee),박효순(Hyo-Soon Park),김병순(Byung-Soon Kim),이감규(Byung-Soon Kim),강태욱(Tae-Wook Kang) 한국실내환경학회 2005 한국실내환경학회지 Vol.1 No.2
This paper describes to evaluate the performance of ventilation as a change of CO₂ concentration with ventilation rate under 35 occupants in a school classroom. Variations of the CO₂ concentration as a function of time are measured at center point of classroom with air ventilation rates by the CO₂ gas monitor. For 800 ㎥/h of ventilation rate in the classroom, the average CO₂ concentration is 913 ppm. The ventilation rate is sufficient to meet acceptable indoor air quality (≤ 1,000 ppm of CO₂, KS school standard) in the classroom of 35 students.